15
Tec
hnical f
eatures
ENGLISH
TEChNICAL DATA ACCORDING ErP DIRECTIVE
OIL fIRED
XC-K
oil 69
oil 100
oil 150
oil 230
oil 300
oil 350
oil 400
Element
Symbol
Unit
Effective nominal output
Prated
kW
66
86
134
202
278
327
385
Efficienza energetica stagionale del
riscaldamento d’ambiente
ƞ
s
%
93
93
93
93
93
93
93
Season efficiency class to
discharge
A
A
A
A
A
A
A
for boilers to heat the room and mixed boilers: useful heat output
Useful heat output with
high temperature capacity
(Tr 60 °C / Tm 80 °C)
P
4
kW
66
86
134
202
278
327
385
Rated heat output efficiency
with high temperature capacity
(Tr 60 °C / Tm 80 °C)
ƞ
4
%
91,3
91,3
91,3
91,4
91,4
91,5
91,7
Useful power at 30% of the rated heat
output with low temperature
capacity (Tr 30 °C)
P
1
kW
20,9
27,5
42,8
64,23
88,7
104
122,4
Performance at 30% of the rated heat
output with low temperature
capacity (Tr 30 °C)
ƞ
1
%
93,7
93,7
93,7
93,7
93,7
93,7
93,7
Boiler with output range adjustment:
YES / NO
NO
NO
NO
NO
NO
NO
NO
Auxiliary electricity consumption
With a full load
elmax
kW
0,390
0,390
0,470
0,600
0,600
0,600
1,400
With a partial load
elmin
kW
0
0
0
0
0
0
0
Standby mode
P
SB
kW
0,050
0,050
0,050
0,050
0,050
0,050
0,050
Other elements
Heat dispersion on standby
P
stb
kW
0,0335 0,0440 0,0690 0,1030 0,1420 0,1670 0,1960
Nitrogen oxides emissions
NOx
Mg/kWh
114
114
114
114
114
114
114
for mixed heating appliances
Declared load profile
-
-
-
-
-
-
-
Water heating energy efficiency
ƞ
wh
%
-
-
-
-
-
-
-
Daily consumption of electricity
Qelec
kWh
-
-
-
-
-
-
-
Daily consumption of fuel
Qfuel
kWh
-
-
-
-
-
-
-
Internal sound power level
Lwa
dB (A)
-
-
-
-
-
-
-
Seasonal DHW efficiency class
-
-
-
-
-
-
-
*
Appliances not covered by Directive 2009/15 / EC )
Содержание XC-K oil 230