Unical .it AQ 15 Скачать руководство пользователя страница 4

4

Heat Stove Ignition

ATTENTION! 

The burn pot must be cleaned before each 

ignition.

Control panel (Fig. 2)

The button 

 is used to ignite or extinguish the 

heat stove and to quit programming.

The buttons   and   are used to adjust the 

temperature,  for  programming  display  and 

functions.

The buttons 

 and 

 are used to adjust the 

heating power.

The button   is used to set the temperature and 

programming functions.

The upper and lower displays are used to view 

the various messages.

Control panel signals

Before  igniting  the  heat  stove  ensure  the  pellet 

tank is filled, the combustion chamber is clean, the 

glazed door is closed, the plug is plugged in and 

the switch at the rear is in position “1”.

The LED is on when parameter 

UT0 1 in the menu is other than 

OFF,  thus  setting  the  weekly  or 

daily program.

ATTENTION!

It is recommended to use wooden pellets of 

maximum 6 mm diameter, not moist.

Fig. 2

6

1

2

3

4

5

“SET”

LED SYMBOL DESCRIPTION

The LED is enabled every time 

the pellets are being filled.

The LED flashes when the panel 

receives a temperature/power 

change  signal  from  the  infrared 

remote control.

The LED is on when the room 

temperature  reaches  the  figure 

set in the SET Water menu.

The  LED  flashes  to  signal  that 

the user/technician menu is 

being  accessed,  or  that  the 

temperature  setting  is  being 

modified. 

The LED switches on when 

the water circulation pump is in 

operation.

1

2

3

4

5

6

Loading pellets into tank

Pellets are loaded into the tank through the specific 
door at the back of the stove.
To load pellets, act as follows:
•   Open the door at the top;
•  Pour the desired amount of pellets into the tank, 

with due care (pour enough pellets to guarantee 
sufficient stove autonomy);

•   Close the door.

LED SYMBOL DESCRIPTION

Содержание .it AQ 15

Страница 1: ...it AQ USER OPERATING INSTRUCTIONS 15...

Страница 2: ...ng long by the heat stove In the event of a fire disconnect electric power use an approved fire extinguisher and if needed call the Fire Brigade Then contact the Authorised Service Centre In congratul...

Страница 3: ...Air inlet pipe diameter Water inlet outlet diameter Power supply Min electric consumption Min electric consumption Tank capacity Kg 145 80 mm 50 mm 3 4 230V 50Hz 90 W 350 W in ignition phase only 17...

Страница 4: ...tting the weekly or daily program ATTENTION It is recommended to use wooden pellets of maximum 6 mm diameter not moist Fig 2 6 1 2 3 4 5 SET LED SYMBOL DESCRIPTION The LED is enabled every time the pe...

Страница 5: ...th a new ignition PLEASE NOTE In the event there should be repeated failed ignitions but the pellets are fed properly there might be an issue connected to breakage of the electrical igniter In this ca...

Страница 6: ...after a few minutes the heat stove will resume normal operation Air temperature range 7 C 40 C ATTENTION To extinguish the heat stove do not unplug it but let the automatic extinction cycle end prolo...

Страница 7: ...Between on off for days from 1 to 7 Selection of days of the week when second time is activated UT11 From 00 00 to 23 50 with 10 minute steps Adjust third time of heat stove ignition UT12 From 00 00 t...

Страница 8: ...3 OFF3 Yes or No ON4 OFF4 Yes or No ON5 OFF5 Yes or No ON6 OFF6 Yes or No ON7 OFF7 Yes or No In the example below the heat stove is lit on Saturday and Sunday only Confirm and continue with button In...

Страница 9: ...e automatically enters the start up stage Press keys and to adjust water temperature while use keys and to adjust operation power To switch off the heat stove press key the heat stove display will rea...

Страница 10: ...stem ALAR NO ACC The heat stove is unable to ignite It is the first ignition Fill the tank with pellet Repeat ignition ALAR NO FIRE Heat stove extinction during operation Fill tank with pellets ALAR S...

Страница 11: ...s Alar No Acc Press the On Off key to reset the alarm Wait for the cooling cycle to be complete clean the burn pot and proceed with a new ignition Extinction during working phase This occurs when the...

Страница 12: ...ction the heat stove goes into extinction mode and the display reads Alar Dep Fail Pellet temperature safety In the extremely rare cases where an excessive temperature occurs inside the tank the manua...

Страница 13: ...emove the burn pot and clean it fig 6 Fig 6 Fig 7 Scraper PERIODICALLY perform complete cleaning of the exchanger every other day When stove is cold operate the exchange duct scraper by pulling and pu...

Страница 14: ...Wiring diagram 230V Mains filter...

Страница 15: ...NOTES...

Страница 16: ...ption or printing errors Furthermore it reserves the right to modify its products as deemed necessary or useful without affecting their essential features 46033 casteldario mantova Italy tel 39 0376 5...

Отзывы: