![Unical .it AQ 15 Скачать руководство пользователя страница 13](http://html2.mh-extra.com/html/unical/it-aq-15/it-aq-15_user-operating-instructions-manual_3721868013.webp)
13
Heat stove cleaning
After burning three-four bags of pellets, open the
lower door and unscrew the two knobs that hold
the inspection pan (Fig. 8);
remove the inspection pan, empty it and only clean
the walls and corners with an ash vacuum cleaner
or suitable tools (Fig. 11).
Fig. 8
Fig. 9
The heat stove needs simple and accurate
cleaning in order to always assure efficient
performance and regular operation.
During internal cleaning of the heat stove the
flue gas fan may be started to prevent spilling
out the ashes. Button and then button must
be pressed to actuate this function. The display
reads “PUL STUF” (stove cleaning). To stop the
fan just press and hold button or wait for a
cleaning cycle to be completed (255 seconds) .
DAILY: remove the burn pot and clean it (fig.6)
Fig. 6
Fig. 7
Scraper
PERIODICALLY: perform complete cleaning
of the exchanger every other day. When stove
is cold, operate the exchange duct scraper by
pulling and pushing the lever located between
the front grates, through which the heating air
comes out (fig. 7-8).
ATTENTION!
Do not clean the glass during heat stove
operation.
Fit the inspection pan back on and screw the two
knobs back in, ensuring it is hermetically closed.
Close the door again.
Glass cleaning: the ceramic glass of the central
door is cleaned with a damp cloth and a little ash,
rub the glass until completely clean. Suitable
detergents may also be used.
ATTENTION:
in the event of lapsed or inadequate cleaning
the heat stove might have functionality
issues such as:
• poor combustion;
• glass blackening;
• burn pot clogging with accumulated ash
and pellets;
• ash deposit and excessive scaling on the
exchanger leading to poor performance.