GENERAL SAFETY GUIDELINES 

Before  beginning  to  operate  on  HP_OWER  units  every  user  has  to  be  perfectly  knowledgeable  about  the  functions  of  the 
equipment and its controls and has to have read and understood the information listed in this manual. 

 

It’s strictly forbidden to remove and/or tamper with any safety device.

 

Children or unassisted disabled persons are not allowed to use the appliance. 
Do not touch the appliance when barefoot or parts of the body are wet or damp. 
Do not clean the unit when the power is ‘ON’. 
Do not pull, remove or twist the  electrical cables coming out from the unit, even if it is disconnected from the main 
power supply. 
Do not step with your feet on the appliance, sit down and/or place any type of object. 
Do not spray or pour water directly on the unit. 
Do not  dispose  of, abandon or leave within reach of children packaging  materials (cardboard, staples, plastic bags, 
etc.) as they may represent a hazard. 

 

Any  routine  or  not-routine  maintenance  operation  shall  be  carried  out  when  the  equipment  has  been  shut  down, 
disconnected from electric power sources. 
Do not put neither your hands nor insert screwdrivers, spanners or other tools into moving parts of the equipment. 
The  equipment  supervisor  and  the  maintenance  man  have  to  receive  suitable  training  for  the  performance  of  their 
tasks in safety. 
Operators have to know how to use personal protective devices and have to know the accident-prevention guidelines 
contained in national and international laws and norms. 

4.1

 

WORKERS’ HEALTH AND SAFETY 

The  European  Community  has  adopted  a  number  of  directives  on  workplace’s  health  and  safety,  which  include  89/391/CEE, 
89/686/CEE,  2009/104/CE,  86/188/CEE  and  77/576/CEE  directives.  Every  employer  shall  implement  such  provisions  and  ensure 
that their workers to respect them. We observe therefore that  

 

Do  not  tamper  with  or  replace  parts  of  the  equipment  without  the  specific  consent  of  the  manufacturer.  The 
manufacturer shall have no responsibility whatsoever in case of unauthorised operations.

 

 

Using  components,  expendable  materials  or  spare  parts  that  do  not  correspond  to  those  recommended  by  the 
manufacturer and/or listed in this manual may be dangerous for the operators and/or damage the equipment 

 

The  operator’s  workplace  has  to  be  kept  clean,  tidy  and  free  from  objects  that  may  prevent  free  movements. 
Appropriate  lighting  of  the  work  place  shall  be  provided  so  as  to  allow  the  operator  to  carry  out  the  required 
operations safely. Poor or too strong lighting can cause risks. 

 

Ensure that work places are always adequately ventilated and that aspirators are working, in good condition and in 
compliance with the requirements of the laws in force. 

4.2

 

PERSONAL SAFETY EQUIPMENTS 

When operating and maintaining the HP-OWER units, use the following personal protective equipment. 

 

Protective  clothing:  Maintenance  men  and  operators  have  to  wear  protective  clothing  that  complies  with  the  basic 
safety requirements currently in force. In case of slippery floors, users have to wear safety shoes with non-slip soles. 

 

Gloves: During maintenance or cleaning operation protection gloves have to be used 

 

 

Mask  and  goggles:  Respiratory  protection  (mask)  and  eye  protection  (goggles)  should  be  used  during 
cleaning and maintenance operations. 

4.3

 

SAFETY SYMBOLS 

The unit features the following safety signs, which has to be complied with: 

 

General hazards 

 

Electric 

shock

 hazard

 

 

Presence of moving organs 

 

Presence of surfaces that may cause injures 

 

Presence of hot surfaces that can cause burns 

 

Содержание HP OWER 60

Страница 1: ...User s and Installer s Manual 60 90 120 150...

Страница 2: ...L CONNECTIONS 11 5 7 1 Wiring terminal block 11 5 7 2 Removal of protective carter for models 120 and 150 12 6 START UP 13 7 SHUTDOWNS FOR LONG PERIODS 13 8 MAINTENANCE AND PERIODICAL CONTROLS 13 9 TE...

Страница 3: ...HP_OWER 3...

Страница 4: ...the manufacturer as an attachment to this manual The company is available to give any detailed information about this manual and to give information regarding the use and the maintenance of its own u...

Страница 5: ...86 CEE 2009 104 CE 86 188 CEE and 77 576 CEE directives Every employer shall implement such provisions and ensure that their workers to respect them We observe therefore that Do not tamper with or rep...

Страница 6: ...ml m for each of the two components Respiratory protection For rescue and maintenance operation in storage tanks use self contained respirator apparatus The vapors are heavier than air and can cause s...

Страница 7: ...t only by QUALIFIED PERSONNEL Before any operation on the unit make sure the power supply is disconnected WARNING MOVING PARTS RISK OF DEATH Disconnect the power supply and ensure that the fan is stop...

Страница 8: ...o not exceed the maximum head loss on the plant side please see the technical data given in the table of Paragraph 12 available pressure head WARNING Connect the pipes to the attacks by using always k...

Страница 9: ...WARNING The water on the charging topping up pipe must be suitably pre filtered from any impurities and suspended particles Make sure that you have installed a cartridge filter removable WARNING Befo...

Страница 10: ...ALVE FO INVERTING CYCLE LR LIQUID RECEIVER EEV ELECTRONIC EXPANSION VALVE FL FILTER M AXIAL FAN SE OUTDOOR AIR TEMPERATURE P CIRCULATOR ON BOARD UNIT IN WATER INLET TEMPERATURE OUT WATER OUTLET TEMPER...

Страница 11: ...witch connections altered or not properly made the guarantee will be invalidated WARNING The remote control panel is connected to the water chiller by means of no 4 wires having a 1 5 mm 2 section The...

Страница 12: ...eutral output of auxiliary electric heater for plant water 230V 50Hz 5A AEH Digital output DO3 230 Vac Phase output of auxiliary electric heater for plant water 230V 50Hz 5A SAN Analogue ST9 digital D...

Страница 13: ...terminate immediately WARNING The summer winter operating mode have to be selected at the beginning of the related season Frequent and sudden changes of this seasonal operating mode have to be avoided...

Страница 14: ...d discharge piping of the compressor are usually high Be careful when working near condensing coils The aluminum fins are very sharp and can cause serious injuries After the maintenance operations clo...

Страница 15: ...R410A R410A R410A Refrigerant quantity kg 1 55 2 10 3 65 3 90 Design pressure high low MPa 4 2 2 7 4 2 2 7 4 2 2 7 4 2 2 7 Hydraulic circuit Water flow rate 3 m3 h 0 99 0 99 1 56 1 56 2 13 2 13 2 44 2...

Страница 16: ...allation and maintenance Read precautions for installation and maintenance at specific chapters on user s and installation s manual PRODUCT FICHE HP_OWER for medium temperature application Tout 55 C S...

Страница 17: ...Tj bivalent temperature Pdh 4 2 kW Tj bivalent temperature COPd 2 73 Tj operation limit temperature Pdh 3 8 kW Tj operation limit temperature COPd 2 35 For air to water heat pumps Tj 15 C if TOL 20 C...

Страница 18: ...Tj bivalent temperature Pdh 7 2 kW Tj bivalent temperature COPd 2 73 Tj operation limit temperature Pdh 6 9 kW Tj operation limit temperature COPd 2 48 For air to water heat pumps Tj 15 C if TOL 20 C...

Страница 19: ...j bivalent temperature Pdh 9 2 kW Tj bivalent temperature COPd 2 69 Tj operation limit temperature Pdh 8 1 kW Tj operation limit temperature COPd 2 29 For air to water heat pumps Tj 15 C if TOL 20 C P...

Страница 20: ...Tj bivalent temperature Pdh 10 2 kW Tj bivalent temperature COPd 2 58 Tj operation limit temperature Pdh 9 4 kW Tj operation limit temperature COPd 2 21 For air to water heat pumps Tj 15 C if TOL 20...

Страница 21: ...Pd 3 50 Tj bivalent temperature Pdh 4 0 kW Tj bivalent temperature COPd 2 21 Tj operation limit temperature Pdh 3 6 kW Tj operation limit temperature COPd 2 00 For air to water heat pumps Tj 15 C if T...

Страница 22: ...Pd 3 26 Tj bivalent temperature Pdh 7 1 kW Tj bivalent temperature COPd 2 10 Tj operation limit temperature Pdh 6 8 kW Tj operation limit temperature COPd 1 99 For air to water heat pumps Tj 15 C if T...

Страница 23: ...OPd 3 56 Tj bivalent temperature Pdh 8 3 kW Tj bivalent temperature COPd 1 93 Tj operation limit temperature Pdh 7 4 kW Tj operation limit temperature COPd 1 69 For air to water heat pumps Tj 15 C if...

Страница 24: ...OPd 3 37 Tj bivalent temperature Pdh 9 3 kW Tj bivalent temperature COPd 1 78 Tj operation limit temperature Pdh 8 5 kW Tj operation limit temperature COPd 1 55 For air to water heat pumps Tj 15 C if...

Страница 25: ...cessary to refer always to the technical data label stuck on right side panel of the unit 12 HEAT PUMPS AVAILABLE HEAD PRESSURE Below the characteristic curves corresponding to Head pressure Water flo...

Страница 26: ...HP OWER 26 13 WATER PUMP CURVES 13 1 MODELS HP_OWER 60 90 13 2 MODELS HP_OWER 120 150...

Страница 27: ...lure in the case of insufficient water flow but it does not ensure the minimum flow rate required in order the unit can work properly Models HP_OWER 60 90 120 150 Cooling capacity for reference kW 5 3...

Страница 28: ...WFCF Water flow rate correction factor PDCF Pressure drops correction factor The water flow rate and pressure drop correction factors are to be applied directly to the values given for operation with...

Страница 29: ...HP_OWER 29 16 DIMENSIONS 16 1 MODELS HP_OWER 60 IN OUT 1 M 16 2 MODELS HP_OWER 90 IN OUT 1 M...

Страница 30: ...HP OWER 30 16 3 MODELS HP_OWER 120 150 IN OUT 1 M...

Страница 31: ...HP_OWER 31 17 WIRING DIAGRAMS 17 1 MODELS HP_OWER 60 90 Temp Sensor Heat Sink...

Страница 32: ...HP OWER 32 17 2 MODEL HP_OWER 120 Temp Sensor Heat Sink...

Страница 33: ...HP_OWER 33 17 3 MODEL HP_OWER 150 Temp Sensor Heat Sink CN604 CN607 DC DC1 DC2 DC DC1 DC2 20A 5mH Reactor...

Страница 34: ...perature sensors for the environment thermohygrometer analysis and manage the double set point for the radiant floor panel that use a dehumidification system The intuitive interface simplifies the use...

Страница 35: ......

Страница 36: ...s It also reserves the right to modify its products as deemed necessary or useful without jeopardising their essential features 46033 casteldario mantova italia tel 39 0376 57001 fax 39 0376 660556 in...

Отзывы: