48
service
service
service
service
service
11
19
PARASITE FLAME
Flame detected upon ignition
Check the wiring of the Ign/Det.
electrode and remove any oxidation.
Check for humidity between drain wire
and ceramic, if necessary, replace
the electrode, press the unblock key,
if the anomaly persists, replace the
electrode (4).
20
20
FIAMMA PARASSITA
Fiamma rilevata dopo lo spe
-
gnimento
Verificare il cablaggio ed even
-
tuali perdite della valvola gas
(3) event. sostituire Valv. gas.
(F) 27
22
ERROR
Flow Gradient
Check if the pump switches off
suddenly.
(F) 23
23
Detected tab panel button pres-
sed for longer than 30 “
Check keypad and reset the
status of the buttons. Or repla-
ce the electronic board
(F) 53
24
Clogged Outlets
Check the Chimneys / Check
the trap.
BLOCK
28
Control circuit problems
Gas Valve
Check the Gas Valve connec
-
tions / Replace the Gas Valve
(3)
/ Replace the Modulation
Board
BLOCK
32
Gas Valve opening time beyond
limit time
Check the parts that generate
the heat requests (thermostats,
electrovalve limit switches, flow
switch, etc.)
89
Flame loss
Check the electrode and its wi-
ring to check the gas pressure
at minimum power, if neces-
sary re-calibrate.
BLOCK
General block for unclassified
anomalies.
Replace Modulation Board.
ERRORS DISPLAYED ON REGOLAFACILE ONLY
-
75
-
Regolafacile external sensor
Replace the external probe /
Regolafacile
-
80
-
Regolafacile Internal Sensor
Replace Regolafacile
-
81
-
Eprom Error of Regolafacile
Replace Regolafacile
service