Wall Air-Conditioner

INDOOR UNIT

OUTDOOR UNIT

Air intake 

grill

Flap

Air intake

Air outlet

WALL AIR-CONDITIONER

FUNCTION SELECTOR

The conditioner is made up of two units connected between themselves through copper pipes (properly insula-
ted) and an electrical power cable.

The indoor unit is installed on the walls of the room to be conditioned.
The outdoor unit is installed on the floor or on the wall on suitable brackets.

Technical data of the air conditioner are printed on the tabels placed on the indoor and outdoor units.

Air outlet 

REMOTE CONTROL

RUN

: the conditioner is in stand-by; through remote control it is possible to set the wished working mode.

TEST

: the conditioner is in test function; it can be used only by authorized staff during the installation or in 

case of troubleshooting.

AUTO

: the conditioner is in automatic function; it is possible to switch the conditioner on if the remote control 

is not working. For the automatic function see paragraph 2.1.

Lift the front panel of the unit to reach the manual control of the con-
ditioner.

Positions of the selector:

STOP

:  the  conditioner  doesn’t  receive  any  signal  from  the  remote 

control;  it  is  possible  to  choose  this  position  in  case  the  conditioner 
should remain inactive for a long period.

4

HEAT

COOL

SET. 

TEMP

RUN 

INDICATOR

DRY

WINDOW 

RECEIVER

DISPLAY

N:B: There are outdoor units that presents only AUTO and STOP mode.

Содержание UND A 9H

Страница 1: ...MANUALE DI USO E MANUTENZIONE UND A 9H UND A 12H UND A 18H UND A 24H...

Страница 2: ...o children Unforeseeable accidents could happen Never block or cover the intake grill and the outlet grill of the air flow The obstruction of these openings causes a reduction in the operative efficie...

Страница 3: ...TE CONTROL RUN the conditioner is in stand by through remote control it is possible to set the wished working mode TEST the conditioner is in test function it can be used only by authorized staff duri...

Страница 4: ...y Timed start stop programming Selection of cool mode directly Selection of heat mode directly Selection of turbo mode Selection of blow mode anti mould Display lighting ON OFF MODE SWING FAN The remo...

Страница 5: ...ct the ideal temperature as to the user s desire Press pushbutton MODE to access this mode In the AUTO working the electronic control auto matically selects the working mode as to the room temperature...

Страница 6: ...TEMP or at a temperature lower than that of the room Example the room temperature is 28 C if we set the cooling at a temperature lower than 27 the compressor will immediately start The device automati...

Страница 7: ...lower than 14 C set a value between 16 C and 20 C on the remote control Don t use the heating mode when the outdoor tempera ture is lower than 5 C HEATING 2 5 To optimize the functioning of the condi...

Страница 8: ...ed Flap movement Flaps This mode is activated by selecting the key SLEEP The symbol appears on the display The function SLEEP automatically adjusts the temperature to make the room more comfortable du...

Страница 9: ...LOW When the TURBO is turned on the whole units runs at the high fan speed to make the ambient temperature swiftly approach to the setting temperature Turn off the TURBO the whole units runs at the se...

Страница 10: ...en the programming and the timed stop press to confirm TIMED START fig 2 To program the timed start the appliance should be off Press every time you press the key or the Timer goes on of 0 5 HR 30 min...

Страница 11: ...th lukewarm water not higher than 40 C and neutral soap Never use aggressive solvents or detergents If the battery of the outdoor unit is clogged remove the leaves and the waste and then remove the du...

Страница 12: ...n There is no confirmation beep from the indoor unit The liquid crystal display doesn t activate How Take off the small lid downward as from the drawing Place the new batteries respecting the symbols...

Страница 13: ...Possono verificarsi incidenti imprevisti Non bloccare o coprire la griglia di aspirazione e di mandata del flusso d aria L ostruzione di tali aperture causa una riduzione dell efficienza operativa del...

Страница 14: ...NDO RUN il climatizzatore in stand by tramite il telecomando possibile impostare la modalit di funzionamento desiderata TEST il climatizzatore in funzione test utilizzabile solamente dal personale aut...

Страница 15: ...a fase del sonno notturno e favorendo il risparmio di energia Programmazione dell accensione spegnimento tem porizzata Seleziona direttamente la modalit raffreddamento Seleziona direttamente la modali...

Страница 16: ...peratura ideale a seconda delle condizioni ambientali Si accede a questa modalit premendo il tasto MODE sul display verr visualizzato il simbolo Nel funzionamento AUTO il controllo elettronico selezio...

Страница 17: ...mbiente Esempio supponiamo che la temperatura del locale sia di 28 C se noi impostiamo il raffreddamento ad una temperatura minore di 27 questo far partire immediatamente il compressore L apparecchio...

Страница 18: ...uando la temperatura minore di 14 C impostare sul telecomando un valore compreso tra 16 C e 20 C Non utilizzare la modalit riscaldamento quando la temperatura esterna inferiore a 5 C RISCALDAMENTO 2 5...

Страница 19: ...la diffusione uniforme dell aria nell ambiente in modalit raffreddamento consigliabile orientare le alette nel senso orizzontale in modalit riscaldamento consigliabile orientare le alette verso il ba...

Страница 20: ...TH BLOW HUMIDITY FILTER TURBO LIGHT FA N AUTO HOUR ON OFF OPER BLOW Questa modalit permette al climatizzatore di rag giungere pi rapidamente la temepratura desiderata in ambiente il ventilatore dell u...

Страница 21: ...ripremere il tasto per riconfermare il tempo di spegnimento ACCENSIONE TEMPORIZZATA fig 2 Per programmare l accensione temporizzata l apparec chio deve essere spento Premere TIMER ad ogni pressione de...

Страница 22: ...niere Pulire l Unit Interna usando un panno inumidito con acqua tiepida non pi di 40 C e sapone neutro Non usare solventi o detergenti aggressivi Se la batteria dell Unit Esterna intasata togliere le...

Страница 23: ...ATTERIE Quando Dall Unit Interna non si riceve alcun bip di conferma Il display a cristalli liquidi non si attiva Come Sfilare verso il basso il coperchietto come da disegno Sistemare le nuove batteri...

Страница 24: ...per le possibili inesattezze se dovute ad errori di trascrizione o di stampa Si riserva altres il diritto di apportare ai propri prodotti quelle modifiche che riterr necessarie o utili senza pregiudi...

Отзывы: