42
Piston LEFT up
Piston LEFT down
Piston RIGHT up
Piston RIGHT down
Plateau to LEFT position
Plateau to CENTER position
Plateau to RIGHT position
Find known plateau position
RSV1
Solid state relay steam 1
RSV2
Solid state relay steam 2
RSV3
Solid state relay steam 3
RSC1
Solid state relay coffee 1
RSC2
Solid state relay coffee 2
RSC3
Solid state relay coffee 3
MAC1
Grinder n°1 (purple)
MAC2
Grinder n°2 (green)
MAC3
Grinder n°3 (orange)
POMP
Motor pump
CHGR
Heating group
EAMAN
Electromagnet of DK door
EVRE
EV filling
EVSE
EV hot water outlet
EVSV
EV steam outlet
EVNK
EV coffee cleaning
EVKG
EV left coffee
EVP1
EV pre infusion 1
EVLCF
Hot-cold milk selection
EVNR
EV steam/EV cleaning-rinsing
EVNO
EV bloc de nettoyage
EVALF1
EV cold milk air
EVNL1
EV cleaning milk
EVALC1
EV hot milk air
EVLG_EVVS
EV left LC latte outlet/EV coil pipe steam
EVAEG
EV water addition left coffee
EVCG_EVRP
EV left LC cappu outlet/EV rinsing purge
EVNC
EV cleaning cappuccino
EVKD_EVM1
EV right coffee/EV mixer 1
EVAED_EVM2
EV water addition right coffee/EV mixer 2
EVCD
EV right LC cappu outlet
EVLD
EV right LC latte outlet
EVP2
EV pre infusion 2
MM1
Motor mixer 1
MM2
Motor mixer 2
MT1
Motor hopper 1
MT2
Motor hopper 2
FAN_SOL
Fan for soluble MT
MPOMP
milk pump
►
Component test
When entering the menu the machine switches to the ‘’test’’ mode (on the duo the right screen is disabled),
the group and steam heating are disabled.
Note: Self-checks 1 and 2 are carried out after having left the test menu, and then the machine goes into
normal operation.
List of testable items, such as
all the solenoid valves of the
machine, the coffee group,
the relays, the grinder(s), etc.
Press = Runs the component
(max. 5 sec.) Release = Stops the
component