background image

Unibor EQ35 Manual 

                   Original instructions 

               Apr 2020 

15 

 

 

 

 

14) MAINTENANCE 

 

 

In order to ‘get the best life’ out of your 

Unibor machine always keep it in good working order.  

Several items must always be checked on Unibor machines. 
Always before starting any job make sure the machine is in good working order and that there 
are no damaged or loose parts. Any loose parts must be tightened. 

Before proceeding with any maintenance work be certain that the power supply is 
disconnected. 

 

Description 

Every operation  

1 week 

1 Month 

Visual check of 
machine for damage 

 

 

 

Operation of machine 

 

 

 

Check brush wear 

 

 

Check magnetic base 

 

 

Check grease 

 

 

Check armature 

 

 

 
Visually check the machine for damage. 

 The machine must be checked before operation for any signs of damage that will affect the 
operation of the machine. Particular notice must be taken to the mains cable, if the machine 
appears to be damaged it should not be used, failure to do so may cause injury or death. 

 
Check operation of the machine. 

The machines operation must be checked to ensure that all components are working correctly.  
 

Machine Brushes 

- should be checked to make sure there is no abnormal wear present (this 

should be checked at least once a week if used frequently). If the brush has worn more than 2/3 
the original length the brushes should be changed. Failure to do so may cause damage to the 
machine. 

Magnetic base

 

 before every operation the magnetic base should be checked to make sure 

that the base is flat and there is no damage present. An uneven magnet base will cause the 
magnet not to hold as efficiently and may cause injury to the operator.  

 
Check machines grease.

 

The gearbox grease should be checked once a month to ensure all moving components are 
covered to prevent wear. The grease should be changed at least once a year to ensure you gain 
the best from your machine. 

Check Armature of the machine. 

This should be checked at least once a month to check that there are no visual signs of damage 
to the body or to the commutator. Some signs of wear will be seen on the commutator over a 
period of time, but this is normal (this is the part that comes into contact with the brushes) 
however, if there are any signs of abnormal damage the part should be replaced. 

Содержание EQ35

Страница 1: ...Unibor EQ35 Manual Original instructions Apr 2020 1 Magnetic drilling machine Model Number EQ35 Serial Number Website www unibor com...

Страница 2: ...cedures Operating instructions Extension cable selection Mounting of cutters Remedies for hole making problems Wiring diagram Exploded view Motor Breakdown Control panel and parts List Maintenance Tro...

Страница 3: ...ipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded 3 Do not expose power tools to rain or wet conditions Water entering a power tool will inc...

Страница 4: ...ind and are easier to control 7 Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the tools operation If damaged have the tool serviced before...

Страница 5: ...h 7 43 64 Length Overall 8 55 64 Nett Weight 26 4 lbs Vibration total values triax vector sum in accordance with EN60745 Vibration emission value a W 1 67 m s Uncertainty K 1 5m s Level of sound press...

Страница 6: ...from the arbor If the machine is accidentally dropped ALWAYS thoroughly examine the machine for signs of damage and check that it functions correctly BEFORE resuming drilling Regularly inspect the mac...

Страница 7: ...is necessary this must be done by the manufacturer or an approved agent in order to avoid a safety hazard Assuming a normal AC supply of the correct voltage it is recommended that the following exten...

Страница 8: ...service is available Improve centre punch and or replace worn parts Replace part or parts 3 Excessive drilling pressure required Incorrectly re sharpened worn or chipped cutter Coming down on swarf l...

Страница 9: ...Unibor EQ35 Manual Original instructions Apr 2020 9 10 WIRING DIAGRAM Standard Wiring Diagram MLC Wiring Diagram...

Страница 10: ...Unibor EQ35 Manual Original instructions Apr 2020 10 11 EXPLODED VIEW OF MACHINE...

Страница 11: ...13 SELPIN410 4 x 10 SELOC PIN 2 14 M0831 RACK 1 15 SC516CAP M5 X 16 CAP HEAD SCREW 1 16 10076 OIL CUP RET CLIP 1 17 10085B M5 NYLOC 1 18 10085A M5X25 KNURLED POINT GRUB SCREW 5 19 10085B M5 NYLOC 5 20...

Страница 12: ...Unibor EQ35 Manual Original instructions Apr 2020 12 12 MOTOR BREAKDOWN 14...

Страница 13: ...V 1 12 EIB038 S TAPPING SCREW C3 9X60 2 13 EIB176 FAN COVER 1 14 EIB177 GEAR PLATE 1 16 UDC009 BEARING 608 2 17 EIB179 LOCATING DOWEL 1 18 EIB039 CIRCLIP 10 1 1 19 EIB181 GEARBOX SEAL 1 20 EIB023 SPUR...

Страница 14: ...Apr 2020 14 13 CONTROL PANEL AND PARTS LIST No Item Description Qty 1 NCP12 NCP SWITCH PLATE MED UNIBOR 3 COLOUR 1 2 NCP001 DRILL STOP START SWITCH 120V 1 3 NCP006 MAGNET SWITCH NCP PANEL B418CG00000...

Страница 15: ...ust be checked to ensure that all components are working correctly Machine Brushes should be checked to make sure there is no abnormal wear present this should be checked at least once a week if used...

Страница 16: ...sound Gear ring bottom of the armature worn out Gear s worn out No grease in gear box Motor humming big sparks and motor has no force Armature damaged Field burned Carbon brushes worn out Motor does n...

Страница 17: ...Steel angle and joists 700N mm M2 Steel angle and joists 850N mm M42 Plate and sheet steel 700N mm M2 Plate and sheet steel 850N mm M42 Aluminium 750Nmm M2 Aluminium 850N mm M42 Brass 700N mm M2 Brass...

Страница 18: ...ditions inappropriate operating conditions overload or insufficient servicing or maintenance 3 Defects caused by using accessories components or spare parts other than original Unibor parts 4 Tools to...