background image

Unibor EQ35 Manual 

                   Original instructions 

               Apr 2020 

 

 

 

 

1) INTENDED USE 

 
The intended use of this magnetic drill is to drill holes in ferrous metals. The magnet is used to hold the drill in 
place whilst the drill is functioning. It is designed for use in fabrication, construction, railways, petrochemical 
and any other applications when drilling ferrous metal.  
Any deviation from its intended use will not be covered by warranty. 

 

 

2) GENERAL SAFETY RULES

 

 

 

WARNING!

 Read and understand all instructions. Failure to follow all instructions listed below, may result 

in electric shock, fire and/or serious personal injury. 

 

SAVE THESE INSTRUCTIONS. 
 
Work area 

1.

Keep your work area clean and well lit

. Cluttered benches and dark areas invite accidents. 

2.

Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases 

or dust.

 Power tools create sparks which may ignite the dust or fumes. 

3.

Keep bystanders, children and visitors away while operating a power tool. 

Distractions can cause you to 

lose control 
 

Electrical safety  

1.

Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all 

codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any 
adaptor plugs. Check with a qualified electrician if you are in doubt as to whether the outlet is properly 
grounded. 

If the tools should electrically malfunction or break down, grounding provides a low resistance path 

to carry electricity away from the user. 
2.

Avoid body contact with grounded surfaces such as pipes, radiators, ranges and refrigerators. 

There is an 

increased risk of electric shock if your body is grounded. 
3.

Do not expose power tools to rain or wet conditions. 

Water entering a power tool will increase the risk of 

electric shock.  
4. 

Do not abuse the cord. Never use the cord to carry the tools or pull the plug from an outlet. Keep cord 

away from heat, oil, sharp edges or moving parts. Replace damaged cords immediately. 

Damaged cords 

increase the risk of electric shock.  
5. 

When operating a power tool outside, use an outdoor extension cord 

marked” W

-A

” 

or

” W”

These cords 

are rated for outdoor use and reduce the risk of electric shock.  
 

Personal safety  

1. 

Stay alert, watch what you are doing and use common sense when operating a power tool. Do not use 

tool while tired or under the influence of drugs, alcohol, or medication. 

A moment of inattention while 

operating power tools may result in serious personal injury.  
2. 

Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and 

gloves away from moving parts. 

Loose clothes, jewelry, or long hair can be caught in moving parts.  

3. 

Avoid accidental starting. Be sure switch is off before plugging in. 

Carrying tools with your finger on the 

switch or plugging in tools that have the switch on invites accidents.  
4. 

Remove adjusting keys or switches before turning the tool on. 

A wrench or a key that is left attached to a 

rotating part of the tool may result in personal injury.  
5. 

Do not overreach. Keep proper footing and balance at all times. 

Proper footing and balance enable better 

control of the tool in unexpected situations.  
6. 

Use safety equipment. Always wear eye protection. 

Dust mask, non-skid safety shoes, hardhat, or hearing 

protection must be used for appropriate conditions.  

 

Содержание EQ35

Страница 1: ...Unibor EQ35 Manual Original instructions Apr 2020 1 Magnetic drilling machine Model Number EQ35 Serial Number Website www unibor com...

Страница 2: ...cedures Operating instructions Extension cable selection Mounting of cutters Remedies for hole making problems Wiring diagram Exploded view Motor Breakdown Control panel and parts List Maintenance Tro...

Страница 3: ...ipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded 3 Do not expose power tools to rain or wet conditions Water entering a power tool will inc...

Страница 4: ...ind and are easier to control 7 Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the tools operation If damaged have the tool serviced before...

Страница 5: ...h 7 43 64 Length Overall 8 55 64 Nett Weight 26 4 lbs Vibration total values triax vector sum in accordance with EN60745 Vibration emission value a W 1 67 m s Uncertainty K 1 5m s Level of sound press...

Страница 6: ...from the arbor If the machine is accidentally dropped ALWAYS thoroughly examine the machine for signs of damage and check that it functions correctly BEFORE resuming drilling Regularly inspect the mac...

Страница 7: ...is necessary this must be done by the manufacturer or an approved agent in order to avoid a safety hazard Assuming a normal AC supply of the correct voltage it is recommended that the following exten...

Страница 8: ...service is available Improve centre punch and or replace worn parts Replace part or parts 3 Excessive drilling pressure required Incorrectly re sharpened worn or chipped cutter Coming down on swarf l...

Страница 9: ...Unibor EQ35 Manual Original instructions Apr 2020 9 10 WIRING DIAGRAM Standard Wiring Diagram MLC Wiring Diagram...

Страница 10: ...Unibor EQ35 Manual Original instructions Apr 2020 10 11 EXPLODED VIEW OF MACHINE...

Страница 11: ...13 SELPIN410 4 x 10 SELOC PIN 2 14 M0831 RACK 1 15 SC516CAP M5 X 16 CAP HEAD SCREW 1 16 10076 OIL CUP RET CLIP 1 17 10085B M5 NYLOC 1 18 10085A M5X25 KNURLED POINT GRUB SCREW 5 19 10085B M5 NYLOC 5 20...

Страница 12: ...Unibor EQ35 Manual Original instructions Apr 2020 12 12 MOTOR BREAKDOWN 14...

Страница 13: ...V 1 12 EIB038 S TAPPING SCREW C3 9X60 2 13 EIB176 FAN COVER 1 14 EIB177 GEAR PLATE 1 16 UDC009 BEARING 608 2 17 EIB179 LOCATING DOWEL 1 18 EIB039 CIRCLIP 10 1 1 19 EIB181 GEARBOX SEAL 1 20 EIB023 SPUR...

Страница 14: ...Apr 2020 14 13 CONTROL PANEL AND PARTS LIST No Item Description Qty 1 NCP12 NCP SWITCH PLATE MED UNIBOR 3 COLOUR 1 2 NCP001 DRILL STOP START SWITCH 120V 1 3 NCP006 MAGNET SWITCH NCP PANEL B418CG00000...

Страница 15: ...ust be checked to ensure that all components are working correctly Machine Brushes should be checked to make sure there is no abnormal wear present this should be checked at least once a week if used...

Страница 16: ...sound Gear ring bottom of the armature worn out Gear s worn out No grease in gear box Motor humming big sparks and motor has no force Armature damaged Field burned Carbon brushes worn out Motor does n...

Страница 17: ...Steel angle and joists 700N mm M2 Steel angle and joists 850N mm M42 Plate and sheet steel 700N mm M2 Plate and sheet steel 850N mm M42 Aluminium 750Nmm M2 Aluminium 850N mm M42 Brass 700N mm M2 Brass...

Страница 18: ...ditions inappropriate operating conditions overload or insufficient servicing or maintenance 3 Defects caused by using accessories components or spare parts other than original Unibor parts 4 Tools to...