background image

Quick Start Guide                                                                                                                                                                                            UTS1000B/T Series 

 

15

 / 

18

 

Instruments.uni-trend.com 

 

Electrostatic  discharge  may  cause  damage  to  component.  Components  can  be  damaged  invisibly  by 
electrostatic discharge during transportation, storage and use. 
The following measure can reduce the damage of electrostatic discharge, 
•    Testing in antistatic area as far as possible

 

•    Before connecting the power cable to the instrument, inner and outer conductors of the instrument   

should be briefly grounded to discharge static electricity; 

•    Ensure all the instruments are properly grounded to prevent the accumulation of static. 

Preparation Work 

1.  Connecting  the  power  cable  and  insert  the  power  plug  into  protective  grounding  outlet;  use  the  tilt 

adjustment bracket as needed for your viewing angle. 

                     

                             

 

Figure 2-1

 

Tilt adjustment 

2. Press the switch on the rear panel

, the spectrum analyzer will enter standby mode. 

3.  Press  the  switch  on  the  front  panel

,  indicator  lights  up  green,  and  then  the  spectrum  analyzer  is 

powered on. 
It takes about 30 seconds to initialize the boot, and then the spectrum analyzer enters the system default 
menu mode. In order to make this spectrum analyzer perform better, it is recommended that warm up 
the spectrum analyzer for 45 minutes after power on. 

 

Usage Tip 

Use External Reference Signal 
If user want to use an external signal source 10 MHz as reference, please connect signal source to the 10 
MHz In port on the rear panel. The measuring bar on the top of the screen will indicate Reference Frequency: 
External. 
 
Activate the Option   
If user want to activate the option, user need to input secret key of the option. Please contact UNI-T office 
to purchase it.   
Refer to the following steps to activate the option you have purchased.   
1.    Save the secret key into USB and then insert it to spectrum analyzer; 
2.    Press [System] key > System Information > add token

 

3.    Select purchased secret key and then press [ENTER] to confirm. 

Touch Operation   

Содержание UTS1000B Series

Страница 1: ...Quick Start Guide UTS1000B T Series 1 18 Instruments uni trend com Quick Start Guide UTS1000B T Series Spectrum Analyzer...

Страница 2: ...urchasing this brand new product In order to use this product safely and correctly please read this manual thoroughly especially the safety notes After reading this manual it is recommended to keep th...

Страница 3: ...the defective products to the individual or entity that is declared in the guarantee In order obtain the warranty service customer must inform the defects within the applicable warranty period to UNI...

Страница 4: ...e Trace set up trace line demodulation mode and trace line operation Marker this maker key is to select marked number type attribute tag function and list and to control the display of these markers P...

Страница 5: ...uency input terminal RF input 50 this port is used to connect the external input signal the input impedance is 50 N Female connector Warning It is forbidden to load the input port with a signal that d...

Страница 6: ...m hold The third line is display the detector type which includes S sampling detection P peak value N normal detection A average f trace operation All detection type are displayed in white letters Tap...

Страница 7: ...orage File System user can use file system to save the correction limiting value measuring result screenshot trace state or other file into internal or external storage and it can be recall System inf...

Страница 8: ...quency Internal Warning It is forbidden to load the input port with a signal that does not meet the rated value and ensure that the probe or other connected accessories are effectively grounded to avo...

Страница 9: ...rface TCP IP port for remote control connecting 6 USB Device Interface Spectrum analyzer can use this interface to connect a PC which can be remote control by the software on the computer 7 Power Swit...

Страница 10: ...roperty loss caused by the user s failure to follow the following safety precautions This device is designed for professional users and responsible organizations for measurement purposes Do not use th...

Страница 11: ...switch is turned off this device is not completely disconnected from the AC power supply CAT I Secondary electrical circuit connected to wall sockets through transformers or similar equipment such as...

Страница 12: ...ine voltage The line voltage of the line fuse of this device is correct Do not used to measure MAINS CIRCUIT Check all terminal rated values Please check all rated values and marking instructions on t...

Страница 13: ...ted current 5A rated voltage 250V by the maintenance personnel authorized by UNI T Disassembly and cleaning There are no components available to operators inside Do not remove the protective cover Mai...

Страница 14: ...on the rear panel and side panel of the instrument So please keep the air flowing through the vents of the instrument housing To prevent excessive dust from blocking the vents please clean the instru...

Страница 15: ...standby mode 3 Press the switch on the front panel indicator lights up green and then the spectrum analyzer is powered on It takes about 30 seconds to initialize the boot and then the spectrum analyz...

Страница 16: ...refer to official site http www uni trend com UTS1000B T Series Programming Manual Help Information The spectrum analyzer s built in help system provides help information for each function button and...

Страница 17: ...t results and accuracy problems To achieve the performance listed in this manual you need a Check whether external device is properly connected and work b Have a certain understanding of the measured...

Страница 18: ...or repair or acquire warranty form please contact the nearest UNI T sales and repair department In addition to permit provided by this summary or other applicable insurance guarantee UNI T does not pr...

Отзывы: