of  power  station,  power  instrument,  front-end  overload  protection,  and  any 
outdoor transmission line. 

 

Certification  CE indicates a registered trademark of EU 

 

Certification  UKCA indicates a registered trademark of United Kingdom. 

 

Certification  Conforms  to  UL  STD  61010-1,  61010-2-030,  Certified  to  CSA  STD  C22.2  No. 

61010-1, 61010-2-030. 

 

Waste 

Do not place equipment and its accessories in the trash. Items must be properly 
disposed of in accordance with local regulations. 

 

EEUP 

This environment-friendly use period (EFUP) mark indicates that dangerous or 
toxic  substances  will  not  leak  or  cause  damage  within  this  indicated  time 
period. The environment-friendly use period of this product is 40 years, during 
which it can be used safely. Upon expiration of this period, it should enter the 
recycling system.   

Safety Requirements 

Warning

 

Preparation 

before use 

Please connect this device to AC power supply with the power cable provided; 

The AC input voltage of the line reaches the rated value of this device. See the product 
manual for specific rated value. 

The line voltage switch of this device matches the line voltage; 

The line voltage of the line fuse of this device is correct. 

Do not used to measure MAINS CIRCUIT. 

Check all 

terminal rated 

values 

Please check all rated values and marking instructions on the product to avoid fire and 
impact  of  excessive  current.  Please  consult  the  product  manual  for  detailed  rated 
values before connection. 

Use the power 

cord properly 

You can only use the special power cord for the instrument approved by the local and 
state standards.  Please  check  whether the insulation  layer  of  the  cord is  damaged  or 
the cord is exposed, and test whether the cord is conductive. If the cord is damaged, 
please replace it before using the instrument. 

Instrument 
grounding 

To  avoid  electric  shock,  the  grounding  conductor  must  be  connected  to  the  ground. 
This product is grounded through the grounding conductor of the power supply. Please 
be sure to ground this product before it is powered on. 

AC power 
supply 

Please  use  the  AC  power  supply  specified  for  this  device.  Please  use  the  power  cord 
approved by your country and confirm that the insulation layer is not damaged. 

Electrostatic 
prevention 

This  device  may  be  damaged  by  static  electricity,  so  it  should  be  tested  in  the 
anti-static  area  if  possible.  Before  the  power  cable  is  connected  to  this  device,  the 
internal and external conductors should be grounded briefly to release static electricity. 

Содержание UTS1000B Series

Страница 1: ...Quick Start Guide UTS1000B T Series 1 18 Instruments uni trend com Quick Start Guide UTS1000B T Series Spectrum Analyzer...

Страница 2: ...urchasing this brand new product In order to use this product safely and correctly please read this manual thoroughly especially the safety notes After reading this manual it is recommended to keep th...

Страница 3: ...the defective products to the individual or entity that is declared in the guarantee In order obtain the warranty service customer must inform the defects within the applicable warranty period to UNI...

Страница 4: ...e Trace set up trace line demodulation mode and trace line operation Marker this maker key is to select marked number type attribute tag function and list and to control the display of these markers P...

Страница 5: ...uency input terminal RF input 50 this port is used to connect the external input signal the input impedance is 50 N Female connector Warning It is forbidden to load the input port with a signal that d...

Страница 6: ...m hold The third line is display the detector type which includes S sampling detection P peak value N normal detection A average f trace operation All detection type are displayed in white letters Tap...

Страница 7: ...orage File System user can use file system to save the correction limiting value measuring result screenshot trace state or other file into internal or external storage and it can be recall System inf...

Страница 8: ...quency Internal Warning It is forbidden to load the input port with a signal that does not meet the rated value and ensure that the probe or other connected accessories are effectively grounded to avo...

Страница 9: ...rface TCP IP port for remote control connecting 6 USB Device Interface Spectrum analyzer can use this interface to connect a PC which can be remote control by the software on the computer 7 Power Swit...

Страница 10: ...roperty loss caused by the user s failure to follow the following safety precautions This device is designed for professional users and responsible organizations for measurement purposes Do not use th...

Страница 11: ...switch is turned off this device is not completely disconnected from the AC power supply CAT I Secondary electrical circuit connected to wall sockets through transformers or similar equipment such as...

Страница 12: ...ine voltage The line voltage of the line fuse of this device is correct Do not used to measure MAINS CIRCUIT Check all terminal rated values Please check all rated values and marking instructions on t...

Страница 13: ...ted current 5A rated voltage 250V by the maintenance personnel authorized by UNI T Disassembly and cleaning There are no components available to operators inside Do not remove the protective cover Mai...

Страница 14: ...on the rear panel and side panel of the instrument So please keep the air flowing through the vents of the instrument housing To prevent excessive dust from blocking the vents please clean the instru...

Страница 15: ...standby mode 3 Press the switch on the front panel indicator lights up green and then the spectrum analyzer is powered on It takes about 30 seconds to initialize the boot and then the spectrum analyz...

Страница 16: ...refer to official site http www uni trend com UTS1000B T Series Programming Manual Help Information The spectrum analyzer s built in help system provides help information for each function button and...

Страница 17: ...t results and accuracy problems To achieve the performance listed in this manual you need a Check whether external device is properly connected and work b Have a certain understanding of the measured...

Страница 18: ...or repair or acquire warranty form please contact the nearest UNI T sales and repair department In addition to permit provided by this summary or other applicable insurance guarantee UNI T does not pr...

Отзывы: