background image

between its laser aperture and the measured object.

Turn on the tachometer. Short press the MODE button to select the non-contact 

measurement mode. (No mode icon will be displayed.)
Short press the UNIT button to select REV.

Long press     to turn on the laser. Point the laser at the object being counted. 

The

 vertical angle is not more than 30°.

 

Note: The lock measurement mode can also be used. For details, please see No.2 

and No.5 in VII. Buttons.

When the counted object has been scanned by the laser, the tachometer will add up 

7

8

Note: Counted objects must be reflective, or they may not be counted.

b.

c.
d.

e.

and No.5 in VII. Buttons.

Start the object under test. The trigger symbol will flash and the measured value 

The tachometer is placed in a stable position with a distance of 50mm to 500mm 

2.  

Non-Contact---REV (Figure 5)

g.

a.

will 

be displayed on the tachometer screen.

 

the count and display the number.

 

Long press       to turn on/off the meter. Short press to turn on/off the backlight.

 

Short press the MODE button to switch between the measurement modes. Long 

press to turn on/off the lock measurement.

Short press the UNIT button to switch between functions/units. Long press to rotate 

the screen.

Short press the MAX/MIN/AVG button to step though MAX/MIN/AVG/last reading. 

Long press to turn on/off the Bluetooth.

 

The Measure button      :

In the lock measurement mode:     will show on the screen. Short press the Measure        

button to start/stop measuring.

Not in the lock measurement mode: 

    

will not show on the screen. Press and hold 

the Measure button to start measuring, and release the button to stop measuring.

Note: After the product is turned on, it enters the unlocked measurement mode by 
default. The Measure button on the side of the product has the same functions 

as

 

that

 

on the front panel.

The STORE button :

View stored data: In the main interface, short press the STORE button to view the 
stored data. At this point, each time users press the STORE button, the screen 

displays the next stored data.

prepare for data storage. The storage number flashes on the screen. Short press 

Store the current data: In the main interface, long press the STORE button to  

1.

2.

3.

4.

5.
a.

b.

6.
a.

b.

VIII. Operation

Do not point the laser directly at users' eyes.

When taking non-contact measurements, keep the product at least 50mm away 

When taking contact measurements, the shaft contacts/contact wheels should be 

 slowly approaching the object under test.

from 

the object under test to avoid product damage or personal injury.

 

Non-Contact (Optical) Measurement

the STORE 

button to select a number. Long press the STORE button to save the 

 

Warning:

To take non-contact measurements, please first loosen the quick release screws on 

both sides of the mechanical adapter and remove the adapter from the product.

1.  

Non-Contact---RPM/Hz (Figure 4)

>
>

>

current data.

Note: When viewing or storing data, short press the Measure button to return to the 
main interface. After data is stored, units cannot be changed. Up to 10 groups of 
data

 

can be stored. When viewing a group of data, short press the MAX button to  

view its MAX/MIN/AVG/last reading.  

Figure. 4

Stop the object under test from rotating.

Cut a piece of 10mm*10mm reflecting tape, stick it on the measured object, and  

tear

 

off the film on the surface of the reflecting tape.

 

between its laser aperture and the measured object.

Turn on the tachometer. Short press the MODE button to select the non-contact 

measurement mode. (No mode icon will be displayed.)

The tachometer is placed in a stable position with a distance of 50mm to 500mm 

a.
b.

c.

d.

Short press the UNIT button to select RPM or Hz.
Long press

     

to turn on the laser. Point the laser at the reflecting tape. The vertical  

angle is not more than 30°.
Note: The lock measurement mode can also be used. For details, please see No.2 

e.
f.

Содержание UT372D

Страница 1: ...UT372D 2 in 1 Tachometer User Manual P N 110401111331X...

Страница 2: ...eatures 3 III Unpacking Inspection 3 IV Safety Instructions 4 V Structure 5 VI Screen Indicators Icons 5 VII Buttons 6 VIII Operation 7 IX Specifications 10 X Bluetooth APP 13 XI Maintenance and Repai...

Страница 3: ...contact wheel 1PC 9 Reflecting tape 10PCS if any accessories are missing or damaged please contact the distributor immediately Warning Before using the tachometer please read the Safety Instructions c...

Страница 4: ...t 3 6in contact wheel measurement contact 4 Bluetooth 5 Store 6 Low battery indicator 7 Storage number NO 1 NO 10 8 Measured values HOLD MAX MIN AVG 9 Measurement functions RPM Hz REV surface velocity...

Страница 5: ...utton View stored data In the main interface short press the STORE button to view the stored data At this point each time users press the STORE button the screen displays the next stored data prepare...

Страница 6: ...MODE button to select 0 1m or 0 6in according to the contact wheel used Stop the object under test from rotating or moving Short press the UNIT button to select the surface velocity unit m min in min...

Страница 7: ...ding digit Ambient temperature 23 5 Ambient humidity 80 RH Temperature coefficient 0 1 accuracy 1 Accuracy Item Accuracy RPM Storage temperature and humidity 20 60 80 RH Frequency 2 Resolution Length...

Страница 8: ...rtment a 1 Preparation Please install the APP iENV IOS or UTienv Android on the smartphone first 2 Installation For IOS devices search iENV in APP Store For Android devices there are three ways to dow...

Отзывы: