background image

2

PREFACE

Thank you for purchasing the new UT320T thermometer. In order to use this product 
safely and correctly, please read this manual thoroughly, especially the Safety 
Instructions part.

After reading this manual, it is recommended to keep the manual at an easily 
accessible place, preferably close to the device, for future reference.

LIMITED WARRANTY AND LIABILITY

UNI-T guarantees that the product is free from any defect in material and workmanship 
within one year from the purchase date.  This warranty does not apply to damages 
caused by accident, negligence, misuse, modification, contamination and improper
handling. The dealer shall not be entitled to give any other warranty on behalf of 
UNI-T. If you need warranty service within the warranty period, please contact your 
seller directly.

This warranty is the only compensation you can obtain. UNI-T will not be responsible 
for any special, indirect, incidental or subsequent damage or loss caused by any 
reason or speculation. As some areas or countries do not allow limitations on implied 
warranties and incidental or subsequent damage, the above limitation of liability and 
stipulation may not apply to you.

ABOUT

Due to different batches, the materials and details of actual products may be 
slightly different from the graphic information. Please refer to the goods received. 
The experimental data in the manual are theoretical values and all from UNI-T's 
internal laboratories, for reference only. Customers cannot use them as bases for 
placing orders. If users have any questions, please contact customer service.

EN

Содержание UT320T

Страница 1: ...P N 110401111770X UT320T 2 in 1 Thermometer User Manual...

Страница 2: ...behalf of UNI T If you need warranty service within the warranty period please contact your seller directly This warranty is the only compensation you can obtain UNI T will not be responsible for any...

Страница 3: ...should only be repaired by professional maintenance personnel using original replacement parts Replace the batteries when the low battery indicator shows to prevent incorrect measurements Please check...

Страница 4: ...ty Value display Temperature difference Infrared Probe measurement Low battery Temperature units Maximum minimum temperature Infrared sensor Single laser LCD Scan l Hold Press it to turn on the thermo...

Страница 5: ...0 or 0 01 t whichever is greater 40 t 32 32 t 572 Measuring range 40 300 40 572 Probe type Minimum measuring depth Operating time Accuracy Probe measurement NTC 12 7mm About 180h backlight on Over ra...

Страница 6: ...e is unfolded the product automatically starts measuring Insert the probe at least 12 7mm into the measured object and wait for the value to stabilize before reading the temperature Press the Scan Hol...

Страница 7: ...determine the temperature Objects of different materials have different emissivity The emissivity of most organic materials painted or oxidized surfaces is about 0 95 The user can use masking tapes or...

Страница 8: ...n this manual Repair the probe if it is damaged Cause Measured value maximum range Measured value minimum range Exceed the minimum maximum operating temperature or infrared sensor damage Low battery I...

Отзывы: