4
/
11
Conductor
voltage
Measure bare conductor with voltage below 60KV (operate with fully-
extended hot stick)
Data hold
In testing mode, press HOLD to hold data (with the symbol “HOLD”
displayed), press again to disable data hold.
Data viewing
The symbol “MR” appears when entering data viewing mode. User can
cycle through the stored data.
Overload
indication
The symbol “OL A” appears.
No-signal
indication
The symbol “no- -” is displayed dynamically if the receiver does not
receive transmission signal.
Auto power off
About 15 minutes after the detector/receiver is powered on, it powers
off automatically to reduce power consumption.
Battery voltage
If the battery voltage of detector/receiver is lower than 4.8V±0.2V, the
symbol “
” flashes for detector and is displayed continuously for
receiver, to indicate replacing battery.
Product weight
Detector: 235g (including battery)
Receiver: 280g (including battery)
Total weight: 2300g (including hot stick and battery)
Operating
temperature &
humidity
-10°C~40°C; 80%Rh
Storage
temperature &
humidity
-10°C~60°C; 70%Rh
Interference
Avoid interference from co-channel signal of 315MHz and 433MHz
Dielectric
strength
AC 220kV/rms (between both ends of fully-extended hot stick)
Structure
Anti-dripping type
Ⅱ
IV.
Structure