Safety Information 

Thank you for purchasing the product. Before test, please carefully read the instructions, safety 
information and precautions in the user manual, and make sure you are skilled at operating 
the product. 

 

Pay  special  attention  to  safe use in  any  case,  particularly  for  measurement  of  line  with 

voltage over AC100V.

 

 

Use hot stick when measuring line with voltage over 600V.

 

 

On-site high-voltage measurement must be performed by authorized trained personnel. 

 

It is forbidden to test conductor or bus bar with voltage over 60KV.  

 

Please pay attention to the labeled words and symbols at the front and rear panels. 

 

Do not place or keep the product in environments with high temperature, high humidity, 

dew or direct sunlight for a long time. 

 

Install battery according to correct polarity, remove battery if the product is not used for a 

long time. 

 

Disassembly and servicing must be performed by authorized qualified personnel. 

 

It is forbidden to use if any component of the product is found damaged. 

 

If the using of the product presents risk, please stop use and then send the product to 

authorized body for maintenance. 

 

The danger symbol “

” at the product and in the user manual identifies that the operator 

must perform safe operation according to the instructions. 

 

The extreme danger symbol “

” at the product and in the user manual identifies that the 

operator must strictly perform safe operation according to the instructions. 

 

It is recommended to perform dielectric test once per year at least (apply AC 220kV/rms 

between both ends of fully-extended hot stick). 
 

I.

 Introduction 

The UT255C Large Current Fork Meter is specifically designed and manufactured to 
measure high-voltage current. Its innovative U-shaped clamp, which features a breakthrough 
in conventional structure, makes on-site measurement effortless.  

This versatile device comprises a current fork meter, a wireless receiver, and a high-voltage 
hot stick. With a wireless transfer distance of up to 100 meters and a current range of AC 
0.00A~9999A, the UT255C can accurately measure the current of high-voltage lines below 
60KV when connected to a hot stick. Conversely, for low-voltage lines below 600V, the 
hook meter can directly measure the current without the need for a hot stick.  

The UT255C is equipped with several useful features, such as data holding and storage. 
Additionally, the adjustable connector at the hot stick and U-shaped clamp jaws make it easy 
to clamp the measured conductor. Furthermore, it can serve as an alternative to the 
High/Low-Voltage Transformer Turns Ratio Tester by measuring the high/low-voltage current 
of primary and secondary loops and calculating the transformer turns ratio. The hot stick is 
characterized as being lightweight, retractable, moisture-proof, high temperature resistant, 
impact-proof, and highly insulated. 

The UT255C Large Current Fork Meter is extensively employed in a variety of settings, 
including substations, power plants, industrial and mining enterprises, detection stations, and 
electrical servicing departments. 

Содержание UT255C

Страница 1: ......

Страница 2: ...escription 6 3 Illustrations 7 VI Operating Instructions 7 1 Operate the detector 5 1 Power on off 6 2 General testing 6 3 Testing zone 6 4 Data transfer 6 2 Operate the receiver 9 1 Power on off 9 2 Introduction 9 3 Data reception 10 4 Data hold 10 5 Introduction 10 6 Data storage 10 7 Data viewing 10 8 Data deletion 10 VII Battery Replacement 10 VIII Packing List 11 ...

Страница 3: ...to the instructions It is recommended to perform dielectric test once per year at least apply AC 220kV rms between both ends of fully extended hot stick I Introduction The UT255C Large Current Fork Meter is specifically designed and manufactured to measure high voltage current Its innovative U shaped clamp which features a breakthrough in conventional structure makes on site measurement effortless...

Страница 4: ... wireless transfer with transfer distance at about 100 meters Display mode 4 digit LCD display designed with backlight function suitable for use in dark places LCD size 47 mm 28 5 mm Product dimensions W H T Detector 107 mm 252 mm 31 mm Receiver 78 mm 165 mm 42 mm Clamp jaws size φ 68mm Hot stick size Diameter φ 45mm Length 850 mm retracted 3600 mm extended Voltage class of hot stick 110 KV Sampli...

Страница 5: ...nutes after the detector receiver is powered on it powers off automatically to reduce power consumption Battery voltage If the battery voltage of detector receiver is lower than 4 8V 0 2V the symbol flashes for detector and is displayed continuously for receiver to indicate replacing battery Product weight Detector 235g including battery Receiver 280g including battery Total weight 2300g including...

Страница 6: ... jaws 2 Detector 3 Power indicator light 4 Power button 5 Adjustable connector 6 Power button 7 HOLD button 8 LCD display 9 Receiver 10 Antenna 11 Retractable hot stick 12 Adjustable connector V LCD Display 1 Display screen ...

Страница 7: ... symbol When viewing data this symbol appears and the group No of stored data is displayed 6 END This is exit symbol The symbol appears when performing exit operation 7 dEL This is data deletion symbol The symbol appears when performing data deletion 8 no This is no signal symbol This symbol is displayed dynamically to indicate the detector may not be in testing mode or receiving location and dist...

Страница 8: ...sonnel The operator must follow the safety information strictly otherwise it may present a risk of electric shock which can cause personal injury or death Danger It is forbidden to test bare conductor or bus bar with voltage over 110kV otherwise it may present a risk of electric shock which can cause personal injury or equipment damage For high voltage testing please connect the hot stick and full...

Страница 9: ...the bottom of the clamp jaws Area A If it is near the top of the clamp jaws Area C the testing error will be doubled approximately or more if at Area B increased by about 1 Figure A Figure C Figure B Conductor Push forward Pull back High voltage current tes ng Grounding Grounding 10Kv 400V transformer Conductor Conductor Grounding Low voltage current tes ng ...

Страница 10: ...the button the receiver is powered on and then enters data reception mode If the brightness of the LCD is low after the receiver is powered on the battery voltage may be low please replace the battery in time 15 minutes after the receiver is powered on the LCD flashes continuously to indicate the receiver is going to power off automatically 30 seconds after that the receiver powers off automatical...

Страница 11: ... then press HOLD or to cycle through the stored data The receiver automatically displays the data of Group 01 when viewing data of last group Long press more than 3 seconds to exit data viewing mode and return to data reception mode The symbol End appears when exiting data viewing mode 6 Data deletion In data viewing mode press HOLD and to delete all stored data and return to data reception mode T...

Страница 12: ...c Carrying box 1 pc Battery AAA alkaline dry battery 8 pc User manual 1 pc Note The content of this user manual cannot be used as a reason for using the product for special purposes The company is not responsible for other losses caused by use The company reserves the right to modify the contents of the user manual If there are changes no further notice will be given Ba ery cover Tighten Loosen Ba...