F. Continuity Testing
H. Temperature
G. 12V Battery
56
Model UT107: OPERATING MANUAL
Range
Resolution
Overload
Protection
1
600Vp
Remark:
Open circuit voltage approximate 2.7V.
The buzzer does not sound when the resistance value
is >100 . The circuit is disconnected.
The buzzer sounds continuously when the resistance
value is 10 . The circuit is in good condition.
The buzzer may or may not sound when the resistance
value is between 10 ~100
l
l
l
l
Range
Resolution
-40
0
C ~ 0
0
C : (3%+9)
0
0
C ~ 400
0
C: (1%+7)
400
0
C ~ 1000
0
C: (2%+10)
Remark:
Overload Protection: Fuse 315mA, 250V, fast type,
5x20mm.
l
-40
0
C ~
1000
0
C
1
0
C
Accuracy
Range Resolution
Accuracy
Overload
Protection
20V
10mV
(3%+5)
Fuse 315mA,
250V, fast type,
5x20mm
Remark:
The Meter has a built-in 120 /2W loaded resistance,
the measured value shown on the display is the value
of the loaded battery.
l