2.
Series and Parallel Settings
2.1 Series Settings:
Press CH1 button for 3 seconds to enter series mode, the “SER” symbol will be on. CH1+ is
the main positive output of series and CH2- is the slave negative output. The series voltage
and current settings can only be adjusted in CH1, and the CH2 settings will follow that of
CH1.
The series voltage total set value is twice of CH1, and the current total value equals to CH1.
To exit the series mode, long press the CH1 button for 3s, the “SER” symbol will disappear.
With the shutdown memory function, the last voltage/current settings and the series mode
will be restored when the device is restarted.
The series output connection is as follows:
2.2 Parallel Settings:
Press CH2 button for 3s to enter parallel mode, the “PARA” symbol will be on. CH1+ is the
main positive output of parallel and CH1- is the slave negative output. The parallel voltage
and current settings can only be adjusted in CH1, and the CH2 settings will follow that of
CH1.
The parallel voltage total value equals to the CH1 voltage, and the current total value is
twice of CH1.
To exit the parallel mode, long press CH2 button for 3s, the “PARA” symbol will disappear.
With the shutdown memory function, the last voltage/current settings and the parallel
mode will be restored when the device is restarted.
The parallel output connection is as follows: