Service Manual                                                                                                                                                                       MSO/UPO3000E Serials products 

 

Instruments.uni-trend.com

                                                                                                                                                                          

4

 / 

27

 

 

Power off

 

The  power  cord  disconnects  the  product  from  the  power  source.  See  location 
description. Do not place equipment in a location where access to the power cord 
is  difficult;  it  must  always  be  accessible  to  the  user  for  a  quick  disconnect  if 
required.

 

Use the correct AC adapter

 

Use only the AC adapter specified for this product.

 

Connect and disconnect properly

 

Do not connect or disconnect probes or test leads while they are connected to a 
voltage source.

 

Use only insulated voltage probes, test leads, and adapters that are supplied with 
the product or directed by Uni-Talk as appropriate for the product. 

Observe all specific ratings

 

To avoid the risk of fire or electric shock, observe all ratings and markings on the 
product.  Please  refer  to  the  product  manual  for  additional  rating  information 
before connecting to the product. Do not exceed the Measurement Category (CAT) 
rating and voltage or current rating of the lowest rated individual component of a 
Product, probe, or accessory. Be careful when using 1:1 test leads as the probe tip 
voltage is transferred directly to the product.

 

Observe all terminal ratings

 

To avoid the risk of fire or electric shock, observe all ratings and markings on the 
product.  Please  refer  to  the  product  manual  for  additional  rating  information 
before connecting to the product.

 

Do  not  apply  to  any  terminal  (including  the  common  terminal)  more  than  the 
maximum rating for that terminal potential

Do not float the common terminal above the voltage rating for that terminal.

 

The measurement terminals on this product are not rated for connection to mains 
or category

 

II, III or IV circuits.

 

Do not operate without cover

 

Do not operate this product with covers or panels removed or the case opened. 
May be exposed to dangerous voltages.

 

Avoid exposed circuits

 

Do not touch exposed connections and components while power is on.

 

Do not run with suspected failure

 

If  you  suspect  damage  to  this  product,  have  it  inspected  by  qualified  service 
personnel.

 

If the product is damaged, please disable it. Do not use the product if it is damaged 
or improperly operated. If in doubt about the safety of the product, turn it off and 
disconnect  the  power  cord.  Clearly  label  the  product  to  prevent  its  further 
handling.

 

Before use, inspect voltage probes, test leads, and accessories for mechanical 
damage and replace them if damaged. If the test leads are damaged, have exposed 
metal, or display wear indicators, do not use

 them. 

Check  the  appearance  of  the  product  before  use.  Look  for  cracks  or  missing 
pieces.

 

Use only specified replacement parts.

 

Use proper fuse

 

Use only the fuse type and rating specified for this product.

 

Wear goggles

 

Wear safety goggles if exposed to high-intensity rays or laser radiation.

 

Do  not  operate  in  wet/humid 
conditions

 

Do  not  operate  in  explosive 
atmospheres

 

Be  aware  that  condensation  may  occur  if  the  device  is  moved  from  a  cold  to  a 
warm environment.

 

Keep product surfaces clean and dry

 

Remove the input signal before cleaning the product.

 

Содержание MSO3000E Series

Страница 1: ...Service Manual MSO UPO3000E Serials products Instruments uni trend com 1 27 Service Manual MSO UPO3000E Serials products ...

Страница 2: ...ormation 5 Theory of operation 5 power supply 6 interface board 6 motherboard 6 Keyboard deck and display 7 Maintainance 8 Prevention of Electrostatic Discharge 8 Check and clean 8 external cleaning 8 display cleaning 9 Return the instrument for repair 9 Removal and Replacement Procedure 9 required equipment 10 remove replacement program 10 Fault exclude 24 service level 24 Check FAQ 24 required e...

Страница 3: ...r warnings and cautions related to the operating system When integrating this device into a system the safety of that system is the responsibility of the system assembler Avoid Fire or Personal Injury Use the correct power cord Use only the power cord specified for this product and certified for the country of use Use the correct power cord Use only the power source specified for this product and ...

Страница 4: ...ing the common terminal more than the maximum rating for that terminal potential Do not float the common terminal above the voltage rating for that terminal The measurement terminals on this product are not rated for connection to mains or category II III or IV circuits Do not operate without cover Do not operate this product with covers or panels removed or the case opened May be exposed to dange...

Страница 5: ...high voltage Know the voltage ratings of the probes you are using and do not exceed these ratings It is important to know and understand two ratings Maximum measured voltage from the probe tip to probe reference lead Maximum float voltage from probe reference lead ground These two voltage ratings depend on the probe and your application Check the Specifications section of the manual for details Co...

Страница 6: ...n for repairs Hazardous voltages or currents may be present in this product Before removing protective plates soldering or replacing components Disconnect power remove the battery if applicable and open the test switch Verify safety after repair Always recheck ground continuity and power supply dielectric strength after performing repairs Terms in the manual These terms may appear in this manual W...

Страница 7: ... names in headers titles table or graph titles or text at the top of the page Material without any specific product designation applies to all products in the brochure Where to find operational information For information on instrument installation operation and networking refer to the Help or Owner s Manual that came with your oscilloscope Theory of operation This chapter describes the electrical...

Страница 8: ...e data from the analog front end the data of the keyboard board and send the data collected by the analog front end to the display screen according to the instructions input by the keyboard board power converter Power is converted to all voltages used for analog and digital circuits throughout the system Standby power is used to keep parts of the system powered at all times when AC power is connec...

Страница 9: ...xterior of the case with a dry lint free cloth or a soft bristled brush If any dirt remains use a cloth or cotton swab dampened with a 75 isopropyl alcohol solution Use a cotton swab to clean up the space around the controls and connectors Do not use abrasives on any part of the case that could damage the case Clean the On Standby switch with a clean towel dampened with deionized water Do not spra...

Страница 10: ...r strapping If the instrument is shipped to Uni Tech service center please attach the following information Owner s address The contact s name and phone number The type and serial number of the instrument The reason for the return A full description of the services required Mark the address of the Unilever service center and the return address on the shipping box in two prominent places Removal an...

Страница 11: ...Prerequisites Whenever you are working on the instrument causing electrostatic damage to components wear a properly grounded anti static wrist and foot strap and work with an anti static mat in a tested anti static environment Steps 1 To remove the knob assembly pull the knob straight off the front panel Finger strength is sufficient to pull the knob Do not use pliers 2 To reinstall the knob align...

Страница 12: ...ve steps Use a PH1 Phillips tip screwdriver to secure the screws Disassembled components The following procedure describes the removal and replacement of the rear assembly Prerequisites To prevent electrostatic damage to components while working on the instrument wear a properly grounded anti static wrist and foot strap and use an anti static mat in a tested anti static environment Remove the rear...

Страница 13: ...s uni trend com 13 27 Steps 1 Use a PH1 Phillips tip screwdriver to remove the upper four screws 2 Use a PH1 Phillips tip screwdriver to remove the lower three screws 3 Use a PH1 Phillips tip screwdriver to remove the two screws on the left and right sides ...

Страница 14: ...ear assembly open manually remove the coax and power cables connected to the motherboard 5 Flatten the front and rear components and manually remove the connections of the coaxial cable on the signal source sub board and the FPC cable on the main board 6 To reinstall reverse the above steps ...

Страница 15: ...o components while working on the instrument wear a properly grounded anti static wrist and foot strap and use an anti static mat in a tested anti static environment Remove the rear cover Remove the rear assembly step 1 Use a PH1 Phillips tipped screwdriver to remove the two screws from the rear chassis frame 2 Use a PH1 Phillips tip screwdriver to remove two more screws from the rear assembly and...

Страница 16: ...To reinstall reverse the above steps Remove the fan The following procedures describe fan removal and replacement Prerequisites To prevent static electricity from damaging components during construction wear a properly grounded anti static wrist and foot strap and use an anti static mat in a tested anti static environment Remove the rear cover Remove the rear assembly Remove the power cover Steps ...

Страница 17: ... remove the fan 3 To reinstall reverse the steps Remove the interface board The following procedure describes the removal and replacement of the interface board Prerequisites To prevent electrostatic damage to components while working on the instrument wear properly grounded anti static wrists and feet and use an anti static mat in a tested anti static environment Remove the rear cover ...

Страница 18: ...rews and then take out the interface board 3 To reinstall reverse the steps Remove the signal source daughter board The following procedure describes the removal and replacement of the signal source daughter board Prerequisites To prevent electrostatic damage to components while working on the instrument wear properly grounded anti static wrists and feet and use an anti static mat in a tested anti...

Страница 19: ...er The following procedure describes the removal and replacement of the front cover Prerequisites To prevent electrostatic damage to components while working on the instrument wear properly grounded anti static wrist and feet and use an anti static mat in a tested anti static environment Remove the front panel knob Remove the rear cover Remove the rear assembly Steps 1 Use a PH1 Phillips tip screw...

Страница 20: ...ostatic damage to components while working on the instrument wear properly grounded anti static wrists and feet and use an anti static mat in a tested anti static environment Remove the rear cover Remove the rear assembly Remove the front cover Steps 1 Use a PH1 Phillips tip screwdriver to remove the five screws 2 Turn over the display screen and fixing bracket and manually remove the FPC cable fr...

Страница 21: ... cover Steps 1 Use a PH1 Phillips tip screwdriver to remove the six screws remove the keyboard deck and remove the attached cables 2 To reinstall reverse the steps Remove the motherboard The following procedures describe system board removal and replacement Prerequisites To prevent electrostatic damage to components while working on the instrument wear a properly grounded anti static wrist and foo...

Страница 22: ...open end wrench to remove the four B s of the front panel assemblyNuts and washers for NC 3 Use a PH1 Phillips tip screwdriver to remove the ten screws that attach the motherboard to the front case assembly and use needle nose pliers to remove one copper post Then take out the motherboard ...

Страница 23: ...failure is an instrument problem If the power fails the instrument needs to be sent back to the Uni Tech service center for repair because other internal electronic components or modules cannot be replaced by the user Check FAQ Use the following table to help isolate possible failures The following table lists problems and possible causes This list is not exhaustive but it can help eliminate quick...

Страница 24: ...tion Start Does the power button turn red Press the power button Confirm Is the power cord connected to the oscilloscope Is the power cord connected to the AC outlet Does the AC outlet have AC power Replace the power cord no yes yes Connect the power cord Does the power button turn green Does the fan spin yes After 2 minutes is the display normal yes Does the oscilloscope pass the power on self te...

Страница 25: ...for adjustment Product Composition Explosion Diagram The product is decomposed into three parts front cover product module assembly and rear cover Figure 3 Exploded View of Backshell Assembly with Handle and Feet Table 4 List of product components The index number Part Name describe 1 front cover Chassis front panel including knobs 2 Product module assembly Product module assembly including front ...

Страница 26: ...y 2 Display mount Used to secure the display to the front assembly chassis 3 Display adapter board assembly Contains a display wage transfer board and FPC cable 4 Keyboard assembly Includes keyboard and FPC cable 5 Front Component Chassis Fix the main board display screen keyboard and other components 6 Motherboard Product core board 7 Silicone button Product buttons and keyboard boards cooperate ...

Страница 27: ...w Table 6 List of rear components The index number Part Name describe 1 Power supply cover Protect people from electric shock 2 Power module Power supply for the whole machine AC power input 3 Rear frame Provides an interface fixing point for the rear panel of the product 4 Fan Machine heat dissipation 5 Interface board Rear panel interface output and transfer ...

Отзывы: