9
MANUAL - SPRAY GUN CLEANERS - UG5000 SERIES
Revision 2007-11
DAILY MAINTENANCE
FILTER PADS AND SCREEN
•
Inspect the filter pad located in the tank of the gun cleaner(UG4000VM) and clean it if there is
a build up of paint debris. Clean by removing the filter pad and washing away paint particles
with clean solvent. Replace the filter pad when damaged or when solvent cannot drain.
•
Inspect the screen, located below the filter pad and clean when necessary(UG4000VM).
•
If a Moisture Filter (not supplied) is used, drain and flush the Moisture Filter by allowing air
under pressure to flow through it.
Replace cap.
REPLACING SOLVENT BOTH SYSTEMS
•
Disconnect the Suction Pipe from the Drain Valve and remove the pipe from the pail. Move
the pail out of the cabinet and recycle or dispose of the wash solvent.
•
Remove the Rinse Pump from the other pail, move the pail out of the cabinet and locate on
left side for use with the suction pipe. .
•
Place a new, full-pail of clean solvent on the right side in front of the cabinet.
•
Insert the Rinse Pump into the full pail on the right and the Suction Pipe into the half-full pail
on the left. Models with a Manual Wash brush also have a tube to supply the brush. The tube
must be inserted through the lid of the left (wash) pail. Models with a Manual Rinse feature
have another tube which needs to be inserted through the lid of the right (rinse) pail.
•
Move the pails into the cabinet and re-connect the Suction Pipe of the left and right pails to
the Drain Valve.