MANUAL - SPRAY GUN CLEANERS - UG1000-3000 SERIES
8
CLEANING SPRAY GUNS AND CUPS - continued
•
Close the lid and turn the “Auto Wash Timer” knob clockwise to start cleaning. The cleaning
cycle takes about 60 seconds
•
Push and hold the "Air Rinse" button for about 3 second to air-rinse the guns.
•
Push and hold the "Clean Rinse" button for about 5 seconds to rinse guns with clean
solvent. This will send a pre-set amount of clean solvent (100 cc) through the jets. Wait 30
seconds for the Rinse Pump to fully recharge before repeating.
The s
olvent flow per clean-rinse cycle is limited to 100 cc to minimize consumption. This
quantity is usually sufficient to clean the inside pasages of the spray guns.
USING THE MANUAL WASH and MANUAL RINSE FEATURES
•
For models with the Manual Wash brush, open the lid and step on the foot pedal (left pedal
on two-pedal models). A dedicated pump delivers wash solvent through the brush.
•
For models with the Manual Rinse feature, open the lid and step on the foot pedal (right
pedal on two-pedal models). Clean solvent is delivered through the brush.
S
olvent flow through the rinse brush is limited to minimize clean solvent consumption.
HOSE CLEANING
•
Models with this feature can be used to clean a paint feeder hose up to 100 feet (30 m)
long. Connect the hose to the two fittings, one on the front and one on the right side. Rotate
the "Mode Selector" handle to the horizontal position and turn the Timer knob clockwise to
start the automatic cleaning cycle.
•
To air-rinse the hose, push and hold the "Air Rinse” button.
•
To rinse the hose with clean solvent, push and hold the "Clean Rinse" button for about 5
seconds. This will use about 100 cc of clean solvent. Wait 30 seconds for the Rinse Pump
to fully recharge before repeating.
•
Disconnect the hose.
AFTER CLEANING
•
Remove the guns and cups from the tank and wipe them dry. Do not store spray guns in the
tank.