![Uni-Mig KUMJRVM150 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/uni-mig/kumjrvm150/kumjrvm150_operating-manual_838730017.webp)
17
Installation set up for MIG with Gasless wire for VIPER 150/182 MIG MMA
(1) Select the MIG function with the MMA/Mig selector switch.
(2) Connect the weld power cable to the Negative socket and tighten it.
(3) Connect the earth cable plug into the Positive socket and tighten it.
(4) Plug the welding torch into the Euro Mig torch connection socket on the front panel, and tighten it.
IMPORTANT : When connecting the torch be sure to tighten the connection. A loose connection can
result in the connector arcing and damaging the machine and gun connector. This damage is not
covered under warranty.
(5) Check the Weld Power Cable is connected to the Negative terminal.
(6) Fit the correct size Knurled drive roller for Gas Less Flux Core wire.
(7) Place the Wire Spool onto the Spool Holder - Note: the spool retaining nut is Left Hand thread. Snip the
wire from the spool being sure to hold the wire to prevent rapid uncoiling. Feed the wire into the wire
feeder inlet guide tube through to the drive roller.
Caution:
Disconnect the Electrode Holder cable from the machine before using MIG function. If cable is not disconnected welding
voltage is present and can cause arcing or flash.
(2/5) Connect weld power lead to
negative terminal
(7) Place wire onto spool holder - (spool retaining
nut is left hand thread ) Feed the wire through the
inlet guide tube on to the drive roller.
(6) Fit the correct sized Knurled Drive roller for
Gas Less Flux Cored wire
NOTE: VIPER 182 not geared
(3) Connect earth
lead
to
(1) Set MIG/MMA selector
switch to MIG
IMPORTANT :
When connecting the torch
be sure to tighten the connection.
(4) Connect Mig torch