PS4000/PS5000 Touchscreen Programmable Thermostat
Table 3. Installer Set-up Menu. (CONTINUED)
55
Installer
Set-up
Number
Installer Set-up
Name
s
e
t
o
N
s
g
n
it
t
e
S
Initial
Setting
Record
0510
Humidifier Pad
Replacement
Reminder
0-humidifier pad replacement reminder off.
1-90 calendar days.
2-180 calendar days.
3-365 calendar days.
0520
UV Lamp
Replacement
Reminder
0-UV lamp replacement reminder off.
1-365 calendar days.
0530
Adaptive Intelligent
Recovery
1-Adaptive Intelligent Recovery control is
activated (system starts early so setpoint is
reached by start of program period).
0-Conventional Recovery (system starts
recovery at programmed time).
0540
Number of Periods
2-two periods available (Wake and Sleep)
4-four periods available (Wake, Day, Evening
and Sleep).
Not shown if non-programmable is
PS5000 ONLY.
PS5000 ONLY.
selected. 2 or 4 applies to all days
of the week. When it is changed the
schedule must be reprogrammed.
0580
Minimum
Compressor
Off Time
5-five-minute compressor off-time setting
(factory setting).
0, 2, 3, 4-other compressor off-time settings.
Compressor delay is a make signal
on all start-up. Display will indicate
"Wait" when activated.
Recommend Minimum
Compressor Off Time. See page
87.
0600
Heat Temperature
Range Stop
40-90-temperature range (1°F increments) of
heating set-point.
Shown in 1/2°C.
0610
Cool Temperature
Range Stop
50-99-temperature range (1°F increments) of
cooling set-point.
Shown in 1/2°C.