background image

Bi-spectrum network camera 

Thermal Sensor Configuration

 

 

User Manual

 

58

 

 

Issue V1.0

2021-10-25

 

Figure 5-3

 

Mode interface 

 

 

Operation Procedure 

Step 1

 

Click 

  in the lower left corner of Sensor Setting, and choose Debug Mode. 

Step 2

 

Choose switch mode from the drop-down list 

Step 3

 

Time mode: Set the Start Time, set the End Time.   

Step 4

 

Click Save, the message " Save succeed " is displayed, the system saves the settings.   

----End   

5.3 Images 

Figure 5-4 shows the

 Image

 setting interface.   

Содержание SN-TPC2553DT-F

Страница 1: ...Bi spectrum Network Camera User Manual Issue V 1 0 Data 2021 10 25...

Страница 2: ......

Страница 3: ...mbols whose meanings are described accordingly Symbol Description It alerts you to fatal dangers which if not avoided may cause deaths or severe injuries It alerts you to moderate dangers which if not...

Страница 4: ...the lens Please do not disassemble the machine This product is an integrated device It has been calibrated before leaving the factory There is a precision detector in the device Disassembling it priva...

Страница 5: ...outdoors take insect and moisture proof measures to avoid circuit board corrosion that can affect monitoring Remove the power plug if the device is idle for a long time Before unpacking check whether...

Страница 6: ...Homepage Layout 9 2 3 Changing the Password 11 2 4 Browse Video 12 2 4 1 Install Plugins 13 2 5 Personnel Count 14 2 6 Setting Local Network Parameters 15 3 Configuring Thermal 19 3 1 Temperature Par...

Страница 7: ...6 FFC Control 62 5 7 Noise Reduction 65 6 Intelligent Analysis 67 6 1 Perimeter 67 6 2 Single Virtual Fence 71 6 3 Personnel Count 75 7 Advanced Intelligent Analysis 80 7 1 Spark Detection 80 7 2 Smok...

Страница 8: ...tream 102 10 2 2 SVC Stream 103 10 2 3 ROI 104 10 2 4 Snapshot 105 10 3 Device 106 10 4 External Device 106 10 5 Privacy Masking 107 10 6 Network Service 108 10 7 Privacy Manager 108 10 8 Protocol 108...

Страница 9: ...o alarm It is suitable for warehouse schools airports parking area stations and other public places need to fireproof and anti theft 1 2 Features Using the uncooled infrared focal plane sensor High th...

Страница 10: ...ew User Manual 2 Issue V1 0 2021 10 25 Providing software and hardware watchdogs and automatic fault recovery Linked heat dissipation structure of the metal enclosure DC 12 V POE 1 3 Device Dimension...

Страница 11: ...Bi spectrum network camera User Manual Product Overview Issue V1 0 2021 10 25 3 Figure 1 1 Dimensions unit mm...

Страница 12: ...location sticker on ceiling or wall drill four holes based on the marks on the sticker Drive the plastic anchors into holes Step 2 Loosen screw 1 to free the body to easy to install the fixed screws...

Страница 13: ...ew 1 Step 3 Install the camera on the ceiling or wall and fixe the screws as shown in Figure 1 3 Figure 1 3 Fix camera Step 4 Connect the multi connector cable and monitor loosen the screw 2 to adjust...

Страница 14: ...ure 1 4 Adjust image Screw 2 Screw 1 1 5 Cable Connection Figure 1 5 the multi connector combination cable of the thermal imaging integrated network camera For details about the multi connector combin...

Страница 15: ...m OUT 1 White alarm IN COM 1 Green alarm IN 1 3 ALARM 2 Alarm in alarm out 2 Orange alarm OUT COM 2 Yellow alarm OUT 2 Grey alarm IN COM 2 Purple alarm IN 2 4 RS485 RS485 interface connects to the ext...

Страница 16: ...8 or a later version to access the web management system otherwise some functions may be unavailable Login system Step 1 Open the Internet Explorer enter the IP address of camera default value is 192...

Страница 17: ...isplayed End logout To logout of system click in the upper right corner of the homepage the login page is displayed after you logout of the system 2 2 Homepage Layout On the homepage user can view rea...

Страница 18: ...7 Stream The visible light channel has four streams You can set details at configuration base stream interface Stream 4 is SVC stream The thermal image channel has two streams 8 play pause switch the...

Страница 19: ...stem Procedure Step 1 Click in the upper right corner of the main page The Change Password dialog box is displayed as shown in Figure 2 3 Figure 2 3 Change password dialog box The change password page...

Страница 20: ...n To ensure the real time video can be played properly you must perform the following operations when you log in to the web for the first time Step 1 Open the Internet Explorer Choose Tools Internet o...

Страница 21: ...trol and plug ins Step 3 Download and install the player control as prompted The login page is displayed when the control is loaded 2 4 1 Install Plugins You will be prompted with a message Click here...

Страница 22: ...erate these buttons as shown in live video Channel switch click the live video the red frame mean the chosen channel During installing plugins you need to close the browser finish the installation log...

Страница 23: ...howing result such as line chart histogram list Click Query to query the data of personnel count User can download the result to local folder End 2 6 Setting Local Network Parameters Description Local...

Страница 24: ...Local Network page is displayed as shown in Figure 2 8 Figure 2 8 Local Network Step 2 Set the parameters according to Table 2 2 Table 2 2 Local network parameters Parameter Description Setting IP Pr...

Страница 25: ...pter Setting method Enter a value manually Default value 255 255 255 0 Default Gateway This parameter must be set if the client accesses the device through a gateway Setting method Enter a value manua...

Страница 26: ...splayed Use the new IP address to log in to the web management system If the message Invalid IP Address Invalid Subnet Mask Invalid default gateway Invalid primary DNS or Invalid space DNS is displaye...

Страница 27: ...eters include temperature unit ambient type ambient temperature cavity temperature correctional coefficient area temperature display mode area temperature type measure mode area alarm interval and so...

Страница 28: ...emperature Parameters interface Step 2 Set the parameters according to Table 3 1 Table 3 1 Temperature parameters Parameter Description Setting Temperature Unit Celsius and Fahrenheit temperature unit...

Страница 29: ...orrection coefficient should be 0 5 2 The measured object temperature is 20 and actual temperature is 19 5 so the correction coefficient should be 0 5 NOTE User should contact the technical support st...

Страница 30: ...f measure modes Setting method Select a value from the drop down list box Default value General Display Alarm Area N A Setting method Enable or disable Default value Disable Area Alarm Interval 1 1800...

Страница 31: ...nd auto Setting method Select a value from the drop down list box Temper Duration 5 60 S Prevent over heat mode is auto the control cover will block for duration time automatically if over heat Settin...

Страница 32: ...er Prominent Enable that the image will show the setting color if the temperature is higher than set value Setting method Enter a value manually Choose one color to show Section Prominent Enable that...

Страница 33: ...d for thermal and visible image to mix There are close mode 1 mode 2 and mode 3 Default value Close End 3 2 Ambient Temperature Figure 3 3 Ambient temperature Table 3 3 parameter of ambient temperatur...

Страница 34: ...0 2021 10 25 3 3 Temperature Area Operation Procedure Step 1 Choose Configuration Thermal Temperature Area The Temperature Area page is displayed as shown in Figure 3 4 Figure 3 4 Temperature area an...

Страница 35: ...ethod Select a value from the drop down list box Default value Rectangle Point Alarm Type Threshold alarm temperature difference alarm section alarm temperature rise alarm are available for alarm type...

Страница 36: ...e alarm is triggered successfully Emission Rate The emission rate is the capability of an object to emit or absorb energy The emission rate should be set only when the target is special material Setti...

Страница 37: ...al is generated the one with the largest difference between the N areas and the average temperature is the alarm area flashing b If A B AA a temperature difference alarm signal is generated the one wi...

Страница 38: ...E ID 0 is the full screen the area cannot be changed the lowest temperature of the full screen the highest temperature of the full screen the lowest temperature of the area the highest temperature of...

Страница 39: ...era will do not detect the temperature of that area The shield areas can be set up to four areas Operation Procedure Step 1 Choose Configuration Thermal Shield Area Figure 3 6 Shield Area Step 2 Enabl...

Страница 40: ...e the right locations to map the three points should not be too close NOTE The images have been calibrated before leaving the factory and can be used directly If the highest temperature detection poin...

Страница 41: ...d of each The three points should cover most areas and two points are located in the diagonal display of the picture Point one is green cross Point two is red cross Point three is blue cross Setting m...

Страница 42: ...anual 34 Issue V1 0 2021 10 25 Figure 3 8 Schedule Linkage Step 2 Tick the output channel Enable alarm record SMTP FTP upload audio alarm and flashlight alarm The audio alarm file will be set at Alarm...

Страница 43: ...rm output User can set the audio file manually Click to upload the audio file the type should be WAV as shown in Figure 3 10 Figure 3 10 Upload audio file Step 3 Set schedule linkage Method 1 Click le...

Страница 44: ...ete the selected alarm time Step 4 Click Apply The message Apply success is displayed the system saves the settings There are seven types schedule linkage to set like threshold alarm threshold warning...

Страница 45: ...ectrum network camera User Manual Configuring Thermal Issue V1 0 2021 10 25 37 Figure 3 11 Bad Point Check Step 2 Click the white point at image click Reset to recover the bad point as shown in Figure...

Страница 46: ...User Manual 38 Issue V1 0 2021 10 25 Figure 3 12 Recover bad point Step 3 Click Apply The message Apply success is displayed the system saves the settings End 3 8 LED Control Param Set the display mod...

Страница 47: ...e four modes can be chosen Open the LED is always lighting Close the LED is closed Flicker set the flicker interval the LED will flicker as the set Timing the LED will lighting at the set time Setting...

Страница 48: ...be Parameter Description Setting Enable Enable it the digital tube will show the temperature of detecting Default value Enable Relate Area ID It is relativity to the Area ID of Parameter Configure cho...

Страница 49: ...onfiguration 4 1 Accessing the Sensor Interface Procedure Step 1 On the web move the cursor to the real time video page and right click on the page A shortcut menu is displayed as shown in Figure 4 1...

Страница 50: ...ting Step 2 Choose Sensor Configure and the Sensor Setting dialog box appears All sensor configure can be modified at debug mode Click in the lower left corner of Sensor Setting and choose Debug Mode...

Страница 51: ...10 25 43 Figure 4 3 Mode Step 2 Choose the switch mode from the drop down list Step 3 Time mode Set the Start Time set the End Time Step 4 Click Save the message Save succeed is displayed the system...

Страница 52: ...Image Parameter Description Configuration Method Brightness It indicates the total brightness of an image As the value increases the image becomes brighter Setting method Drag the slider Default value...

Страница 53: ...Default value 50 Contrast It indicates the measurement of different brightness levels between the brightest white and darkest black in an image The larger the difference range is the greater the contr...

Страница 54: ...a value from the drop down list Default value Indoor Mirror It is used to select the pixel location of an image Normal The image does not flip Horizontal The image flips to the left and right Vertical...

Страница 55: ...ing Parameter Description Configuration Method Exposure Mode The exposure modes include Auto The system performs auto exposure based on the monitoring environment Manual You can set Shutter Setting to...

Страница 56: ...is valid in Iris Priority mode You can select a maximum shutter speed As the value increases the image becomes brighter Setting method Select a value from the drop down list Default value 1 25 Max ga...

Страница 57: ...Bi spectrum network camera User Manual Visible Sensor Configuration Issue V1 0 2021 10 25 49 Figure 4 7 WB Table 4 4 describes the parameters on the WB tab page...

Страница 58: ...oring scenario when the color temperature changes Auto camera adjusts automatically Tungsten at tungsten lamp Environment Fluorescent fluorescent environment Daylight at daylight environment Shadow at...

Страница 59: ...the image switches between the colored state and the black and white state based on the brightness In day mode the image is colored In night mode the image is black and white Day mode The image is co...

Страница 60: ...Trans D to N Day transit to night Setting method Drag the slider Default value 50 Trans N to D Night transit to day Setting method Drag the slider Default value 50 Delay N A Setting method Drag the s...

Страница 61: ...Method 2D NR Auto manual default value is auto By comparing and screening the images of the two frames before and after the noise point position is found out and gain control is carried out on them Se...

Страница 62: ...e Sensor Configuration User Manual 54 Issue V1 0 2021 10 25 End 4 9 Enhance Image Figure 4 10 shows the enhance image Setting tab page Figure 4 10 Enhance image Table 4 7 describes the parameters on t...

Страница 63: ...detect any spotlight diffused by object vehicle and compensate it for obtaining clearer image Setting method Drag the slider Default value 50 BLC It indicates Back Light Compensation BLC automatically...

Страница 64: ...ccessing the Sensor Interface Operation Procedure Step 1 On the Internet Explorer interface or the client software interface choose channel 2 select and right click the surveillance image to the set a...

Страница 65: ...Thermal Sensor Configuration Issue V1 0 2021 10 25 57 Figure 5 2 Thermal channel sensor setting Step 2 Choose Sensor The Sensor Configuration dialog box is displayed as shown in Figure 5 3 End 5 2 Mo...

Страница 66: ...edure Step 1 Click in the lower left corner of Sensor Setting and choose Debug Mode Step 2 Choose switch mode from the drop down list Step 3 Time mode Set the Start Time set the End Time Step 4 Click...

Страница 67: ...is displayed the system saves the settings NOTE Brightness It indicates the total brightness of an image As the value increases the image becomes brighter It ranges from 0 to 100 Contrast It indicates...

Страница 68: ...t corner of Sensor Setting and choose scene Step 2 Choose mirror mode from drop list Step 3 Click Save the message Save succeed is displayed the system saves the settings NOTE Mirror providing the sel...

Страница 69: ...docolor setting interface Figure 5 6 Set pseudocolor setting interface Step 1 Click in the lower left corner of Sensor Setting and choose set pseudo color Step 2 Choose polarity LUT mode from drop lis...

Страница 70: ...ely white The temperature field of the scene is converted to images by using the grayscale ranging from 0 to 255 Different polarity modes can be converted to different display images The most common s...

Страница 71: ...an periodically improve the image quality This component is called flat field correction FFC When controlling the FFC the FFC shields the sensor array so that each portion of the sensor can collect un...

Страница 72: ...tively frequent which is normal Manual In the manual FFC mode the camera does not automatically perform the FFC based on the temperature change or the specified period You can press the Do FFC button...

Страница 73: ...nd adjust Click the icon and camera perform the action Manually End 5 7 Noise Reduction Figure 5 8 shows the Noise reduction interface Figure 5 8 Noise reduction interface Table 5 2 lists the Noise re...

Страница 74: ...Configuration User Manual 66 Issue V1 0 2021 10 25 Parameter Description Setting noise Select from the drop down list box Default value Close 3DNR Decrease the image noise How to set Select from the d...

Страница 75: ...Enter Area Leave Area The parameters of these analysis alarm are roughly similar so we will describe someone in detail as a reference 6 1 Perimeter Description The perimeter function refers to that a...

Страница 76: ...ep 2 Set all parameters for perimeter Table 6 1 describes the specific parameters Table 6 1 Perimeter Parameter Description Parameter Description Setting Channel Channel 1 visible light Channel 2 ther...

Страница 77: ...no alarms may be generated How to set Click to enable Limit Target Size Default configuration OFF Output Channel If you check to set the Output Channel and the device is connected to an external alar...

Страница 78: ...or the line drawing fails Any shape with 32 sides at most can be drawn The quantity of deployment areas is not limited yet and will be described in future when a limit is applied Step 4 Set deploymen...

Страница 79: ...l fence is a line that is set at a concerned position within the monitored field of view and specifies the forbidden travel direction An alarm is generated when the targets of specified types such as...

Страница 80: ...et all parameters for the single virtual fence Table 6 2 describes the specific parameters Table 6 2 Parameters of single Virtual Fence Parameter Description Setting Channel Channel 1 visible Channel...

Страница 81: ...square centimeters and the maximum 100000 square centimeters When setting the target size you need to well set Real size in scene in advanced parameters otherwise no alarms may be generated How to set...

Страница 82: ...virtual fence is generated Setting a single virtual fence Click a line and the trip line turns red to select the single virtual fence and set its direction as Positive Reverse or Bidirectional or dele...

Страница 83: ...0 2021 10 25 75 6 3 Personnel Count Description User can draw line to count the personnel at the special area Procedure Step 1 Select Intelligent Analysis Personnel Count to access the Personnel Count...

Страница 84: ...hannel How to set Choose from drop down list Default value 1 Enable Enable the button to enable the alarm How to set Click Enable to enable Default value OFF OSD Enable Enable the OSD the count data w...

Страница 85: ...w to set Click Enable to enable Default value OFF Alarm Threshold the threshold of enable alarm How to set Enable Input a value in the area box Default value 1000 Output Channel If you check to set th...

Страница 86: ...fence is generated Setting a single virtual fence Click a line and the trip line turns red to select the single virtual fence and set its direction as Positive Reverse or Bidirectional or delete the...

Страница 87: ...t the alarm time within 0 00 24 00 from Sunday to Saturday NOTE When you select time by dragging the cursor the cursor cannot be moved out of the time area Otherwise no time can be selected Method 3 C...

Страница 88: ...he smoking if someone smoke in the indoor where is forbidden smoking The smoke flame detection can be used for detecting smoke and fire it can be send alarm information to avoid fire getting worse Fir...

Страница 89: ...le to enable Default value OFF Output Channel If you check to set the Output Channel and the device is connected to an external alarm indicator the alarm indicator signals when an alarm is triggered H...

Страница 90: ...oint move the cursor to draw a line and then click to generate another point This is how a line is generated In this way continue to draw lines to form any shape and right click to finish line drawing...

Страница 91: ...k again or inverse selection to delete the selected deployment time Figure 7 2 Deployment Time Setting Interface End 7 2 Smoke Flame Detection Description The smoke flame detection function refers to...

Страница 92: ...le to enable Default value OFF Output Channel If you check to set the Output Channel and the device is connected to an external alarm indicator the alarm indicator signals when an alarm is triggered H...

Страница 93: ...oint move the cursor to draw a line and then click to generate another point This is how a line is generated In this way continue to draw lines to form any shape and right click to finish line drawing...

Страница 94: ...yment time Click again or inverse selection to delete the selected deployment time Figure 7 4 Deployment Time Setting Interface End 7 3 Fire Spot Detection Description The fire spot detection function...

Страница 95: ...le to enable Default value OFF Output Channel If you check to set the Output Channel and the device is connected to an external alarm indicator the alarm indicator signals when an alarm is triggered H...

Страница 96: ...e alarm video How to set Click to enable Alarm Record Default value OFF SMTP Enable the button to enable SMTP serve How to set Click to enable SMTP Default value OFF FTP Upload Enable the button to en...

Страница 97: ...time Method 1 Click left mouse button to select any time point within 0 00 24 00 from Monday to Sunday as shown in Figure 6 2 Method 2 Hold down the left mouse button drag and release mouse to select...

Страница 98: ...Bi spectrum network camera Advanced Intelligent Analysis User Manual 90 Issue V1 0 2021 10 25 Figure 7 7 Deployment Time Setting Interface End...

Страница 99: ...1 8 AI Multiobject Step 1 At Configuration AI Multiobject interface user can enable full body detection vehicle detection to detect the person and vehicle as shown in Figure 8 1 Figure 8 1 AI Multi ob...

Страница 100: ...ve the settings End Parameter Description How to set Full body detection The camera will snap the whole body when someone appear in live video The detection frame is blue Enable Vehicle detection The...

Страница 101: ...uration Alarm Alarm Output to access the Alarm Output setting interface as shown in Figure 9 1 Figure 9 1 Alarm output interface Step 2 Set alarm output of channel name enable valid signal and alarm t...

Страница 102: ...wn in Figure 9 2 Figure 9 2 Disk alarm interface Step 2 Enable the disk full alarm when the disk is full it will alarm Step 3 Set alarm interval and tick output channel Step 4 Click Apply to save the...

Страница 103: ...network card ID and enable exceptional alarm to set alarm interval Tick output channel Step 3 Click Apply to save the settings click refresh will return last settings End 9 4 I O Alarm Linkage Procedu...

Страница 104: ...linkage interface Step 2 Choose alarm input and trigger mode set name enable other linkages such as alarm input PTZ linkage Alarm Record SMTP and FTP upload Step 3 Set alarm schedule choose the durat...

Страница 105: ...he Motion Alarm setting interface as shown in Figure 9 5 Figure 9 5 Motion alarm interface Step 2 Choose channel and enable the motion alarm set alarm interval and sensitivity enable other linkages su...

Страница 106: ...rface as shown in Figure 9 6 Figure 9 6 Push message interface Step 2 Enable the push message you will receive the message when the alarm happened Step 3 Click Apply to save the settings click Refresh...

Страница 107: ...1 0 2021 10 25 99 Figure 9 7 Sound alarm output interface Step 2 Click to upload the audio file browse the file and the formate should be wav There are 12 default files you can listen and test the fil...

Страница 108: ...Figure 9 8 Upload audio file Step 4 Click Apply to save the settings click Refresh will return last settings End 9 8 Audio Abnormal Output Procedure Step 1 Select Configuration alarm Audio Abnormal Ou...

Страница 109: ...2 Enable the audio abnormal detection enable sudden rise sudden drop when happen the condition of enable it will alarm Step 3 Tick the output channel enable alarm record SMTP FTP upload Step 4 Set ala...

Страница 110: ...0 2021 10 25 10 Other Web Configurations 10 1 Device Information You can view the information about device as shown in Figure 10 1 Figure 10 1 Device information interface End 10 2 Stream 10 2 1 Base...

Страница 111: ...encode type video encode level audio encode type resolution frame rate frame interval bit rate type and bit rate from all drop list Step 3 Set name of base stream enable smart encode Step 4 Click Appl...

Страница 112: ...0 25 Figure 10 3 SVC stream interface Step 2 Choose SVC stream ID elementary stream ID and P frame rate from drop list Step 3 Click Apply The message Apply success is displayed the system saves the se...

Страница 113: ...sage Apply success is displayed the system saves the settings End 10 2 4 Snapshot Step 1 Choose Configuration Stream Snapshot as shown in Figure 10 5 Figure 10 5 Snapshot interface Step 2 Choose snaps...

Страница 114: ...Device You can set local network device port data and time camera OSD microphone CVBS system voice denoise and software licenses as shown in Figure 10 6 Figure 10 6 Device interface End 10 4 External...

Страница 115: ...e 10 7 External device interface End 10 5 Privacy Masking Choose Configuration Privacy masking You can set privacy masking if some area need keep secret drag mouse to select the area to cover double c...

Страница 116: ...u can set 802 1x DDNS PPPoE Port mapping SMTP IP filter CGI alarm service center SNMP and QOS 10 7 Privacy Manager Add user account manage the users permission As shown in Figure 10 9 Figure 10 9 Priv...

Страница 117: ...9 Device Log Choose configuration device log You can view operation log and alarm log or collect all log information as shown in Figure 10 11 Figure 10 11 Device log interface 10 10 Maintenance Choose...

Страница 118: ...0 Issue V1 0 2021 10 25 Figure 10 12 Maintenance interface 10 11 Local Config Choose configuration local config You can choose the snapshot picture format change the save path of snapshot and local re...

Страница 119: ...onnected to a router or switch with a QOS function and the priority rule of the corresponding mark is configured on the network device the network device will preferentially pass the data packet of th...

Страница 120: ...ions User Manual 112 Issue V1 0 2021 10 25 Figure 10 14 QOS page Step 2 Input the value range from 0 to 63 audio video dscp alarm dscp and command dscp Step 3 Click Apply The message Apply success is...

Страница 121: ...wered on and the temperature of the cavity is unstable The temperature of the cavity is stable within 15 to 30 minutes after the device is powered on The target configuration is incorrect Check whethe...

Страница 122: ...Make sure thermal mapping and thermal calibration is configured correctly by checking if face square in thermal image is covering the face and the cross is in the middle of target s forehead 2 Check i...

Отзывы: