Bi-spectrum network camera
User Manual
Configuring Thermal
Issue V1.0
(
2021-10-25
)
29
Parameter
Description
Setting
Group ID
The ID can be chosen into one
of six groups, or no group. The
group will be alarm following
as the next rules:
A=The highest temperature of
groups (the highest temperature
of N regions is the largest)
B=Average temperature of
groups (average temperature of
N regions)
WA=Warning value
AA=Alarm value
a. If A-B >= WA, a temperature
difference warning signal is
generated ---> (the one with the
largest difference between the
N areas and the average
temperature is the alarm area
flashing)
b. If A-B >= AA, a temperature
difference alarm signal is
generated ---> (the one with the
largest difference between the
N areas and the average
temperature is the alarm area
flashing)
c. If the warning and alarm
conditions are met at the same
time, the alarm signal will be
generated first.
[Setting method]
Select a value from the
drop-down list box.
Step 3
Set temperature area.
1.
Tick an area ID.
2.
Press and hold the left mouse button, and drag in the video area to draw a
temperature area, as shown in Figure 3-5. Right-click to finish the area
selected.