Event Setting
11.1
Alarm Out
This section is designed to set up detailed settings for alarm output(s) when events occur. Make sure
you have enabled alarm output in each event section to activate this function.
Figure: Alarm Output Settings
Alarm Out
Enable :
Select “On” to activate this function.
Note
The available number of alarm output will vary by different model, please check
“
Appendix: Product Comparison-I/O Port
”
for details.
Method : Pulse/ Normal
There are 2 methods to proceed with alarm output as follows.
Normal: It’s the standard method to execute alarm output function where user can define a
period
of duration from options within dropdown menu of Post Duration.
Figure: Normal Method Settings
Pulse: By selecting this method, user can specifically define both the duration and interval time
individually for alarm output. Besides, counts for alarm output can also be concretely customized.
Figure: Pulse Method Settings
Post Duration : Infinite/ 5/ 10/ 15/ 30 (sec)
Set a period of duration for alarm output under only Normal method. Infinite means unlimited and
continuous triggering for alarm output.
Type: NO/ NC
Define which type to be adopted for triggering alarm output.
NO (Normally Opened): An alarm will be triggered when the external contact closes.
NC (Normally Closed): An alarm will be triggered when the external contact opens.
On Time : 0.1 ~ 200 (sec)