71
LPR Series | Universal
User’s Manual
General
This page contains general settings shared by all VA functions. That is, prior to set up each VA function,
it is fundamental to define the settings here well, before advancing to other function settings.
Figure: General Settings
Basic Setting
Sensitivity : High/ Mid high/ Mid/ Mid Low/ Low
Choose a sensitivity level from the dropdown menu to define a clear threshold for triggering all VA
functions. High represents VA functions will be triggered easily by slight events, whilst Low, on the
other hand, stands for triggering occurs only when major events happen.
Size Settings
Max Object Size
(REQ-VA-010)
Draw a desired maximum object size within the right-side preview window followed by clicking the
“Save” to enable the settings. Any object larger than th
e maximum size defined here will neither be
detected, nor triggered.
Min Object Size
(REQ-VA-010)
Draw a desired minimum object size within the right-side preview window followed by clicking the
“Save” to enable the settings. Any object smaller than the minimum size defined here will neither be
detected, nor triggered.
Note
Press the arrow buttons at the upper-right corner to expand or collapse the setting
pages of “Max Object Size” and “Min Object Size” individually.
It is strongly recommended to define a fitting size range in accord with desired
objects to be detected. By doing so, the accuracy of VA functions will be escalated
by a large scale.