20
Electrical Data Measured window.
The window this command opens lets you choose between two options for the power curve to be displayed:
NOTE
:
the STC selection button is present only when the brand and model of the comparison panel have been entered.
Representations of the OPC and STC power curves
Save:
press the Save button to access the Saving module measurement function. The window that opens for this
function lets you enter a comment, which is saved in the measurements tab. Press the Save button in the dialog box to
save the measurements and the comment.
The saved measurements can be displayed using the "Measurements Archive" Menu, accessed from the main menu
(page 9 of the "MEASUREMENTS ARCHIVE" chapter).
Dialog box for saving the measurements
Module (or String)
:
Module (or String): on selecting one of these commands the "Electrical Data Measured" table is displayed (OPC
conditions and STC reference standard if comparison previously requested).
Power
:
This command displays on the I-V curve graph of the panel or string the power curve (yellow colour) as well.
OPC:
the instrument shows the trend for power output from the module/string under real OPC conditions
(calculated with the measured values).
STC:
the instrument shows the trend for power output from the module/string under STC standard conditions
(calculated by transferring the values measured under STC standard conditions in compliance with IEC/EN 60891
standard).