background image

 

 

 

 
 

 

             

F-2

                         

ULVAC CRYOGENICS INCORPORATED

 

of the breakdown is found to be a fault of ULVAC CRYOGENICS. 

 

(2)

 

Damage during transportation 

When  damage  by  delivery/transportation  is  admitted,  the  product  will  be 

repaired free of charge within the range of the  guarantee expressed in the sales 

contract. 

 

(3)

 

Breakdown repairs 

There will be a charge for breakdown repairs, replacements and on-site visits 

for  the  following  seven  conditions.  In  those  cases  the  cost  shall  be  your  own 

expense even though the product is within the warranty period. 

 

① 

Breakdowns due to improper storage or handling, careless accident, software 

or hardware design by the customer.   

② 

Breakdowns  due  to  modifications  of  the  product  without  consent  of  the 

manufacturer. 

③ 

Breakdowns  due  to  maintenance  of  the  product  without  authentic  parts  or 

breakdowns  resulting  from  using  the  product  outside  the  specified 

specifications of the product. 

④ 

Breakdowns  due  to  contamination  or  corrosion  caused  by  user’s  use 

conditions. 

⑤ 

Breakdowns  due  to  natural  disasters  (such  as  fire,  earthquake,  flood, 

lightning, salt damage, and so on) , environmental pollution, irregular voltage, 

and /or usage of undesignated power source. 

⑥ 

Breakdowns that are outside the terms of warranty. 

⑦ 

Consumables and/or replacement service. 

 

Since the above services are limited to within Japan, diagnosis of failures, etc are 

not  performed  abroad.  If  you  desire  the  after  service  abroad,  please  contact 

ULVAC CRYOGENICS and consult us for details in advance.   

 

2.2   Exclusion of opportunity loss from warranty liability 

Regardless  of  the  gratis  warranty  term,  compensation  to  opportunity  losses 

incurred to your company or your customers by failures of ULVAC CRYOGENICS 

products  and  compensation  for  damages  to  products  other  than  ULVAC 

CRYOGENICS products and other services are not covered under warranty. 

Содержание STC-1C Series

Страница 1: ...TEMPERATURE CONTROLLER STC 1C series Instruction Manual STC 1C STC 1C INV Export Control Policy We recommend that ALL customers be sure to follow all rules and regulations such as Foreign Exchange an...

Страница 2: ......

Страница 3: ...where our product is used The personnel are also required to have specialized knowledge skills and qualification on the electricity the machinery the cargo handling and the vacuum Especially the perso...

Страница 4: ...wns resulting from using the product outside the specified specifications of the product Breakdowns due to contamination or corrosion caused by user s use conditions Breakdowns due to natural disaster...

Страница 5: ...splay Serial No Option Part Model Optional Part Serial No 4 Notes for repair and maintenance requests We may decline your request for the repair or the maintenance of our products if you refuse to giv...

Страница 6: ...fer this instruction manual or any of its parts to a third person without written permission from ULVAC CRYOGENICS 2 Information in this document might be revised without a previous notice for the spe...

Страница 7: ...ould result in severe injury or loss of life A caution describes safety hazards or unsafe practices which could result in personal injury or equipment damage Toxic gas or chemicals used There is a ris...

Страница 8: ...F 6 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...

Страница 9: ...res 1 1 2 Types 1 2 Specifications 2 3 Component Descriptions 3 3 1 STC 1C 3 3 2 STC 1C INV 4 4 Connector specifications 5 4 1 STC 1C 5 4 2 STC 1C INV 6 5 Accessories or Optional cable 7 6 Installatio...

Страница 10: ...TC 1C INV external dimensions drawing 22 Appended Figure 3 STC 1C electric wiring diagram 23 Appended Figure 4 STC 1C INV electric wiring diagram 24 TABLES Table 3 1 STC 1C Component Descriptions 3 Ta...

Страница 11: ...frigerator is two phase motor and is delivered with the condition the conversion adapter connected with the main body of STC 1C series Item Quantity Super trap temperature controller STC 1C Series 1 F...

Страница 12: ...Table of Contents IV ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...

Страница 13: ...onal and local laws and regulations We provide Safety Data Sheet SDS of our products upon your request Please contact us if necessary WARNING The cryopumps or cryocoolers may contain residue of hazard...

Страница 14: ...IW 2 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...

Страница 15: ...n Figure 1 1 below This series has two types STC 1C and STC 1C INV The main difference between them is how to control refrigerator power STC 1C is a relay control method it is connected between the co...

Страница 16: ...utput 24VDC MAX 1A REF OUT Relay output three phase 144VAC 240VAC MAX 2A TC OUT K thermocouple output Note Not insulated from TC IN Insulation must be done referring to Section 7 in case of using it I...

Страница 17: ...to section 9 1 Status LED R T The LED lamp lights up when contact outputs on the rear terminal board Refer to section 8 for operation and section 9 2 for factory default value HI TEMP READY REF ON Th...

Страница 18: ...E720series Lights at the temperature that the refrigerator unit is turned ON while the compressor unit is in operation FR D720series Lights at the temperature unit is turned ON while the compressor un...

Страница 19: ...2 N Power source input Single phase 100VAC 220VAC 3 E Earth REF IN NJC 204 PF NANABOSHI 1 R Refrigerator power source input 2 S Refrigerator power source input 3 T Refrigerator power source input 4 E...

Страница 20: ...ower source input Single phase 100VAC 220VAC 2 N Power source input Single phase 100VAC 220VAC 3 E Earth INV ON OFF NCS 257 P NANABOSHI 1 R COMP Operation signal 200VAC input 2 S COMP Operation signal...

Страница 21: ...tity Clamp For fixing main body 2 Electrical cable GP HS01 3 pin female ULVAC CRYOGENICS For SOURCE 100VAC only 1 3m Conversion adapter 1 U type ULVAC CRYOGENICS 3 phase 2 phase connector For conversi...

Страница 22: ...tion 7 for wiring Table 5 2 Optional cables When you purchase our system check with our sales representative about the cable No Item Type Appearance Intended model REF IN cable ST HS22 For two phase F...

Страница 23: ...humidity is 80 RH or below dew point Where highly intense vibration or impact is generated or transferred Near high voltage power lines or where inductive interference can affect the operation of the...

Страница 24: ...detachment of the front panel Tighten the clamps with the prescribed torque Recommended tightening torque 0 5N m 0 8N m WARNING Be sure to use the STC 1C series controller attaching in your equipment...

Страница 25: ...ust be in separate conduit from other equipments or AC power lines or control lines for other equipments Otherwise STC 1C series operation will be interfered If separate conduits cannot be supplied ke...

Страница 26: ...ocouple in parallel or connect a controller to TC OUT of STC 1C series STC 1C series may display inaccurate temperature In this case be sure to install an insulation distributor in proper place as sho...

Страница 27: ...fter wiring make sure that wiring has been done correctly If difference signal has been connected damage to STC 1C series may result Also make sure that the input power is within the allowable range C...

Страница 28: ...tor motor K Thermocouple cable ST HS10 for extending K Thermocouple ST HS10 REF IN Cable For 2 phase Motor For 3 phase Motor Or Female Male Female Male For 2 phase Motor Or For 3 phase Motor Male Male...

Страница 29: ...tor for 3 phase refrigerator motor K Thermocouple cable ST HS10 for extending K Thermocouple Inverter control cable ST HS60 ST HS10 ST HS60 Wiring to be done by customer Inverter Control Cable Inverte...

Страница 30: ...ghts up the temperature will be controlled between REF OFF set value and REF ON set value Refer to Figure 8 1 Turn off the compressor unit when operation to stop The refrigerator is OFF Table 8 2 Desc...

Страница 31: ...ller STC 1Cseries Instruction Manual ULVAC CRYOGENICS INCORPORATED 17 Figure 8 1 STC 1C series operation Cooling Trap Trap Regeneration Initialvalue Initialvalue Initialvalue Initialvalue Compressorun...

Страница 32: ...key to select parameter to set LED The selected parameter LED flashes CEL The cell displays parameter The cell flashes Press or key to change the setting value Press key untill returning to the initi...

Страница 33: ...operated for one year 10K Approx 4 h Approx 35 000 year 5K Approx 12 h Approx 100 000 year 1K Approx 120 h Approx 1 million year Command Discription Factory default value Recommended setting range 1 R...

Страница 34: ...ws 400K and does not move K thermocouple and its cable line are not connected Connect K thermocouple and its cable line correctly referring to section 7 Disconnection of K thermocouple Replace K therm...

Страница 35: ...N READY R T HI TEMP 91 6 90 2 1 6 2 9 2 9 2 7 6 23 41 5 26 237 100 240V 10 1A 50 60Hz B N A U D E C V EC A B AC100 240V C V D E A U B N REF IN AC144 240V 50 80Hz N C TC OUT TC IN READY HI TEMP R T STC...

Страница 36: ...REF OFF R T UL VA C CR YO GE NI CS I NC 2 9 1 6 2 9 6 2 7 26 237 41 5 23 100 240V 10 1A 50 60Hz I NV O N OF F INV TC IN TC OUT SOURCE AC100 240V B A C E C A B G REF IN F ON E COM D RH R T HI TEMP READ...

Страница 37: ...E1 31 32 33 34 31 32 33 34 11 12 14 15 13 16 11 12 13 14 15 16 05 06 01 02 03 04 01 02 05 04 03 06 CN9 UL1015 20 UL1015 20 REF2 REF1 EX E REF12 REF13 EX E REF11 REF3 EX E ND00525 04 ND00525 03 ND0052...

Страница 38: ...E E2 E1 31 32 33 35 34 21 22 25 24 26 35 24 UL1015 20 E2 CN3 ND00564 02 REF BOARD CN1 CN4 22 21 26 25 ND00525 04 ND00525 03 ND00525 01 ROOMTEMP BOARD UL1015 20 31 32 34 33 06 05 06 05 01 04 03 02 01 0...

Страница 39: ...Chigasaki Kanagawa 253 0085 Japan Sales Tel 81 467 85 8884 Service Engineering Division Tel 81 467 85 9366 Fax 81 467 83 4838 ULVAC CRYOGENICS KOREA INC www ulvac cryo co kr 107 Hyeongoksandan ro Che...

Страница 40: ...CS 2 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...

Страница 41: ...04 2013JU05 2013NR06 2018MH07 2022DR08 First edition The product name on the cover has been amended Introduction has been revised UCN address has been changed SERVICE NETWORK has been revised Notes ha...

Страница 42: ...Revision History R 2 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...

Отзывы: