10. Caution
Prior to operation, read this manual carefully and operate the pump using with great care
and responsibility. When installing to the SGT process, take necessary measure s to
prevent from damaging the equipment.
<Other>
If any abnormality such as defective condition is found in the equipment, stop the
operation immediately and contact your local agency or ULVAC KIKO.
11.
Trouble shooting
Trouble symptom
How to check Result
Corrective
action
Pressure difference
Large
Replace the element
Check pressure
difference between
inlet and outlet side
Pressure difference
None
Able to use
Large
Cleaning is required
also check the
element ensure that
no clogging.
①
Element is
clogged
Check the particle at
INLET pipe flange
parts (Visual look)
Small
Continue to use
Bad corrosion
and partly coming off
Replace the housing
②
corrosion of the
inside housing
Visual look
Corrosion only
Continue to use
Check the element
According to item
①
According to item
①
According to item
①
Good
O-ring is satisfactory
O-ring (upper lid)
Damage, crack and
hardening
Replace O-ring
Good Satisfactory
・
SGT leak check for
piping system
Unsatisfactory Repair
Foreign body
Remove
③
Vacuum
performance is not
satisfactory
Check the foreign
body (visual look)
No foreign body
Satisfactory
※
Element is completely sealed with degas condition by ULVAC KIKO.
Open the package just before using SGT-100, 200.
5