Ulvac OMT-100A Скачать руководство пользователя страница 6

 

Table 4 Frequency of Element Replacement 

Model No 

Frequency of element replacement 

OMT-100A 

1500 to 2000 hours 

OMT-200A 

1000 to 1500 hours 

If pumping is continued for a long time or if the oil mist trap is severely contaminated 

with suction gas, it is recommended to disassemble and clean it, in addition to the above 

checks, to maintain performance. For disassembly, contact your local ULVAC KIKO 

representative. 

5.3 Consumables

     

Table 5 List of Consumables 

 

Description 

Q'ty

Element 1 

OMT-100A 

Relief valve spring 

Element 1 

OMT-200A 

Relief valve spring 

Check valve spring 

Common parts 

O-ring (P-41) 

5.4 Replacement 

of 

Element 

If the element is clogged, the trap cannot separate oil mist completely. If much oil 

mist is discharged when restarting the pump after a pause for more than 30 minutes, 

replace the element. Scheduled replacement is recommended according to the element 

replacement frequency in Table 4. 

!

 

DANGER 

  If the vacuum pump is used to pump toxic gas, pump oil as well as oil mist trap will be 

toxic.    Beware of it in maintenance. 

!

 

CAUTION 

 

When replacing the element, wear rubber gloves, goggles and other protective wear.    If 

your hand is stained with vacuum pump oil, wash the stained portion with water and 

soap.    If oil is admitted into your eye, wash your eye with clean water for at least 15 

minutes and then see doctor for treatment. 

 

   

-6- 

<Replacement of element> 

Refer to "7. EXPLODED VIEW" for the names of components. 

(1)  Make sure that the pump is shut down. 

(2)  Remove the top cover as shown in Fig. 3. 

 

 

 

 

 

 

 

 

 

Fig. 3 Removal of top cover 

(3)  Remove the relief valve spring, OMT retainer and element from the case in that 

order. 

(4)  Replace the element with a new one and center it with the OMS receiver to install 

it. 

 

 

 

 

 

 

 

 

 

 

Fig. 4 Installation of element 

-7- 

Содержание OMT-100A

Страница 1: ...fully read this manual and fully understand the specifications operating procedure and safety cautions NOTE No part of this manual may be reproduced for use by a third party without written consent by...

Страница 2: ...tact your local distributor CAUTION Do not use the oil mist trap for corrosive gas Damage or failure can result 02 CAUTION Do not modify the oil mist trap If modified troubles of the oil mist trap wil...

Страница 3: ...s and preventive actions 1 1 1 DANGER Hazardous gas hazardous material Hazard Preventive actions You may be injured by contact with pump oil that has been turned toxic in the oil mist trap or with tox...

Страница 4: ...e that interferes with the passage of a gas connected to the exhaust port The internal pressure of the oil mist trap will rise and the unit may be damaged or fail This unit is not explosion proof NOTE...

Страница 5: ...s 5 INSPECTION AND MAINTENANCE 5 1 Maintenance Check the following once a day during operation 1 Oil leak in the connection with the vacuum pump 2 Oil mist or oil gushing out from the case 3 Unusual s...

Страница 6: ...ause for more than 30 minutes replace the element Scheduled replacement is recommended according to the element replacement frequency in Table 4 DANGER If the vacuum pump is used to pump toxic gas pum...

Страница 7: ...rate of oil mist trap 5 The check valve is not functioning properly 5 Repair or clean the check valve Oil is not recovered into the pump case 1 The pump is running continuously at a high suction press...

Страница 8: ...Malfunctions caused by special atmospheric conditions such as salt damage inflammable c Malfunctions caused by usage conditions that differ from those stated in the user manual performance specificat...

Отзывы: