Ulvac OMT-100A Скачать руководство пользователя страница 4

 

If the relief valve is opened, it means that the element is not functioning properly. In 

this case, oil mist will be generated.    Replace the element. 

!

 

NOTE 

 

Replace the element if it is clogged with dust or the like.    Otherwise, oil mist may be 

discharged. 

2.3 Dimensional 

Drawing 

 

 

 

 

 

 

 

 

Fig. 1    Dimensional drawing for OMT-100A/OMT-200A 

 

3. INSTALLATION 

3.1 Installation 

Select a place as free from dust and moisture as possible, where the oil mist trap can 

be easily installed, removed, checked, and cleaned, and install the unit perpendicularly 

to the pump. 

The connecting screw for this unit is G1 by the ISO standard. Select a pump of which 

exhaust port connection is compatible with this standard. 

Refer to "0.4.2 Storage, installation and environmental conditions during operation" 

for environmental conditions. 

!

 

WARNING 

  The unit may be ruptured if the maximum flow rate of the unit is exceeded.  The 

maximum flow rate for the OMT-100A is 120 L/min and that for the OMT-200A is 240 

L/min. 

-2- 

!

 

WARNING

 

  Do not plug the exhaust port nor operate the unit with a device that interferes with the 

passage of a gas connected to the exhaust port. The internal pressure of the oil mist trap 

will rise and the unit may be damaged or fail. 

  This unit is not explosion proof. 

!

 

NOTE 

  If the oil mist trap is tilted or turned sideways or installed upside down, oil may 

overflow or gush out. Install it perpendicularly to the pump exhaust port. 

 

3.2 

Installing the Unit on ULVAC KIKO Vacuum Pump 

Table 2 gives ULVAC KIKO vacuum pumps on which the OMT-100A/ 

OMT-200A can be mounted. 

 

Table 2 

ULVAC KIKO Vacuum Pumps to which   
OMT-100A or OMT-200A can be Attached 

Model No 

OMT-100A 

OMT-200A 

Model No of ULVAC 

KIKO pump 

G-101S/D 

GHD-100A/B/C/D 

GLD-136A/C 

GLD-201A/B 

3.3 Installation 

and 

Removal

 

(1)  Make sure that the pump is at stop. 

(2)  Mount an O-ring (P-41, accessory) in the connection of the oil mist trap. 

(3)  Attach the oil mist trap to the pump exhaust port of which connection is 

compatible with the oil mist trap and turn it clockwise holding the case at the side. 

(See Fig. 2.) 

(4)  Before removing the oil mist trap, make sure that the pump is at stop 

and turn it counterclockwise holding the case at the side. 

!

 

NOTE 

  When installing and removing the oil mist trap, do not turn it by holding the 

top cover.    Damage or failure can result.

 

 

 

-3- 

Содержание OMT-100A

Страница 1: ...fully read this manual and fully understand the specifications operating procedure and safety cautions NOTE No part of this manual may be reproduced for use by a third party without written consent by...

Страница 2: ...tact your local distributor CAUTION Do not use the oil mist trap for corrosive gas Damage or failure can result 02 CAUTION Do not modify the oil mist trap If modified troubles of the oil mist trap wil...

Страница 3: ...s and preventive actions 1 1 1 DANGER Hazardous gas hazardous material Hazard Preventive actions You may be injured by contact with pump oil that has been turned toxic in the oil mist trap or with tox...

Страница 4: ...e that interferes with the passage of a gas connected to the exhaust port The internal pressure of the oil mist trap will rise and the unit may be damaged or fail This unit is not explosion proof NOTE...

Страница 5: ...s 5 INSPECTION AND MAINTENANCE 5 1 Maintenance Check the following once a day during operation 1 Oil leak in the connection with the vacuum pump 2 Oil mist or oil gushing out from the case 3 Unusual s...

Страница 6: ...ause for more than 30 minutes replace the element Scheduled replacement is recommended according to the element replacement frequency in Table 4 DANGER If the vacuum pump is used to pump toxic gas pum...

Страница 7: ...rate of oil mist trap 5 The check valve is not functioning properly 5 Repair or clean the check valve Oil is not recovered into the pump case 1 The pump is running continuously at a high suction press...

Страница 8: ...Malfunctions caused by special atmospheric conditions such as salt damage inflammable c Malfunctions caused by usage conditions that differ from those stated in the user manual performance specificat...

Отзывы: