Ulvac OMT-100A Скачать руководство пользователя страница 3

 

Contents 

 

 

 

 

 

 

 

       

      Page 

0. INTRODUCTION .................................................................................... 01 

0.1 Before Use of This Instrument............................................................ 01 

0.2 Denotations in This Manual ................................................................ 01 

0.3 Safety Cautions ................................................................................... 03 

0.4 Receipt and Storage of Oil Mist Trap ................................................. 03 

0.4.1  Receipt of oil mist trap................................................................ 03 

0.4.2  Storage, installation and environmental   

conditions during operation ........................................................ 03 

1. FOR SAFE OPERATION .......................................................................... 1 

1.1 Danger Inherent to This Instrument and Safety Measures .................... 1 

1.1.1 DANGER    Hazardous gas, hazardous material............................ 1 

2. OVERVIEW OF OIL MIST TRAP............................................................ 1 

2.1 Design Basis.......................................................................................... 1 

2.2 Functions of Relief valve ...................................................................... 1 

2.3 Dimensional Drawing ........................................................................... 2 

3. INSTALLATION ....................................................................................... 2 

3.1 Installation............................................................................................. 2 

3.2 Installing the Unit on ULVAC KIKO Vacuum Pump .......................... 3 

3.3 Installation and Removal ...................................................................... 3 

4. PERFORMANCE OF OIL MIST TRAP................................................................4 

4.1 Limit of Pump Operation Hours ........................................................... 4 

5. INSPECTION AND MAINTENANCE........................................... 5

 

5.1 Maintenance .......................................................................................... 5 

5.2 Scheduled Inspection ............................................................................ 5 

5.3 Consumables ......................................................................................... 6 

5.4 Replacement of Element ....................................................................... 6 

5.5 Troubleshooting .................................................................................... 9 

6. DISPOSAL ............................................................................................... 10 
7. 

EXPLODED VIE

 ................................................................................. 10 

 

WARRANTY 

 

 

1.  FOR SAFE OPERATION 

1.1 

Danger Inherent to This Unit and Safety Action 

Before operating or checking this unit, carefully read this section and fully understand 

potential hazards and preventive actions. 

1.1.1 

!

 

DANGER    Hazardous gas, hazardous material 

Hazard Preventive 

actions 

You may be injured by 

contact with pump oil 

that has been turned 

toxic in the oil mist trap 

or with toxic substance 

on the unit. 

1) Put on protective wear against toxic 

substances when inspecting the unit. 

2) When repairing the unit or discarding 

toxic substances, have a wastes treatment 

specialist render it non-toxic. 

3) Have wastes disposed of by authorized 

waste treatment specialist. 

 

2.  OVERVIEW OF OIL MIST TRAP 

2.1 Design 

Basis 

The Model OMT-100A/OMT-200A oil mist trap separates oil mist discharged from 

an oil rotary pump during operation to reduce the discharge of oil mist. The oil that 

has collected in the oil mist trap is returned into the pump case. Being small in size, 

light in weight, and simple in structure, the unit can be easily maintained and repaired. 

Table.1 Design Basis 

Model No 

OMT-100A 

OMT-200A 

Name 

Oil mist trap 

Weight (kg) 

0.43 

0.55 

Outside dimensions (mm) 

113 diameter 

×

 135 H 

Mounting position 

Vertical 

Connecting screw 

G-1 

 

2.2 

Functions of Relief valve 

Clogged element will narrow the flow path and increase the inner pressure of the 

pump. If the inner pressure rises to 9.8

×

10

-2

MPa(G), the relief valve will 

automatically be opened to prevent pressure rise. 

-1- 

Содержание OMT-100A

Страница 1: ...fully read this manual and fully understand the specifications operating procedure and safety cautions NOTE No part of this manual may be reproduced for use by a third party without written consent by...

Страница 2: ...tact your local distributor CAUTION Do not use the oil mist trap for corrosive gas Damage or failure can result 02 CAUTION Do not modify the oil mist trap If modified troubles of the oil mist trap wil...

Страница 3: ...s and preventive actions 1 1 1 DANGER Hazardous gas hazardous material Hazard Preventive actions You may be injured by contact with pump oil that has been turned toxic in the oil mist trap or with tox...

Страница 4: ...e that interferes with the passage of a gas connected to the exhaust port The internal pressure of the oil mist trap will rise and the unit may be damaged or fail This unit is not explosion proof NOTE...

Страница 5: ...s 5 INSPECTION AND MAINTENANCE 5 1 Maintenance Check the following once a day during operation 1 Oil leak in the connection with the vacuum pump 2 Oil mist or oil gushing out from the case 3 Unusual s...

Страница 6: ...ause for more than 30 minutes replace the element Scheduled replacement is recommended according to the element replacement frequency in Table 4 DANGER If the vacuum pump is used to pump toxic gas pum...

Страница 7: ...rate of oil mist trap 5 The check valve is not functioning properly 5 Repair or clean the check valve Oil is not recovered into the pump case 1 The pump is running continuously at a high suction press...

Страница 8: ...Malfunctions caused by special atmospheric conditions such as salt damage inflammable c Malfunctions caused by usage conditions that differ from those stated in the user manual performance specificat...

Отзывы: