background image

 

1.INTRODUCTION 

This oil mist trap is specially designed to trap oil mist that is entertained with 

exhaust air during the operation of oil sealed rotary vacuum pump. It also has a 

function of returning trapped oil to the vacuum pump from which oil mist is 

exhausted. Because of those faculties, oil consumption rate of operating 

vacuum pump is remarkably reduced. 

 

 

2.SPECIFICATIONS 

Table.1 Specification 

Available flow capacity 

Max. 60 L/min 

Weight 105 

Dimension 

65 (DIA) 

×

 93 (H) mm 

Installation Vertical 

direction 

Life of element 

Every, 1,500 to 2,000 Hr of operation 

Connector G 

3/4 

 

 

3.UNPACKING 

Please confirm the following checkpoint. 

1)

 

Appearance. 

2)

 

Fixation of every screw. 

If you find any defect. Please contact our dealer or branch. 

 

 

4.INSTALLATION 

Table.2 OMT-050A fits our vacuum pump. 

Pumping speed(L/min)  5

10 20

30 40

50 

OMT-050A 

Fits our vacuum pump 

G-5DA 
G-10DA

G-20DA, G-25SA 
GHD-031A 
GHD-031B 

G-50DA, G-50SA 
GLD-040 
GLD-051 
GLS-051 

Remove standard discharge port and screw up OMT-050A. 

Содержание OMT-050A

Страница 1: ...r safe and efficient operation be sure to go through this manual before attempting to use this pump After reading the manual keep it in your file for future reference Specifications given in this manu...

Страница 2: ...fication Available flow capacity Max 60 L min Weight 105 g Dimension 65 DIA 93 H mm Installation Vertical direction Life of element Every 1 500 to 2 000 Hr of operation Connector G 3 4 3 UNPACKING Ple...

Страница 3: ...5minutes or high vacuum below 40Pa operation is required 6 MAINTENANCE 1 Element of OMT 050A is subject to exchange every 1 500 to 2 000 hour of operation due to filling up of the element by dust 2 W...

Страница 4: ...r 5 Remove Top cover 6 Remove Element and then remove Element stopper Gasket from Case 7 After exchange Gasket for new one fix it 8 Put Element stopper on Gasket 9 After exchanging Element for new one...

Страница 5: ...DESCRIPTION Q ty REMARKS No DESCRIPTION Q ty REMARKS 1 Top cover 1 9 Check valve 1 2 Case 1 10 Spring B 1 3 Element stopper 1 11 Element 1 4 Check valve stopper 1 12 Seal washer 1 5 Pressure valve st...

Страница 6: ...ecial atmospheric conditions such as salt damage inflammable c Malfunctions caused by usage conditions that differ from those stated in the user manual performance specifications maintenance and inspe...

Страница 7: ...c Head office 291 7 Chausubaru Saito city Miyazaki 881 0037 Japan Tel 81 983 42 1411 Fax 81 983 42 1422 Sales division 1 10 4 Kitashinyokohama Kohoku ku Yokohama city Kanagawa 223 0059 Japan Tel 81 45...

Отзывы: