background image

 

       

 
 
 

14 

 

Ultrasonic cleaning detergents 

Detergents  are  a  vital  component  in  the  ultrasonic  cleaning  process,  aiding  in  the 
removal and loosening of debris from the surfaces of items placed in the tank while also 
intensifying the power of the ultrasonic activity.  

Ultrawave  offer  a  range  of  specially  formulated  ultrasonic  detergents  for  use  in 
applications including medical and heavier industrial cleaning requirements. 

Ultraclean SA

: A general purpose cleaning detergent suitable for use on aluminium 

and other soft metals. 
 

Ultraclean M2

: A general purpose cleaning detergent for all plastics, glass and metals 

(except aluminium and other soft metals), which is also suitable for use on medical 
instruments. 
 

Ultraclean CS

: Moderate grease and heavy contaminant removal for industrial 

cleaning applications. Not suitable for use on aluminium and other soft metals. 
 

Ultraclean CBX

: An alkaline detergent for heavy grease and carbon removal. Not 

suitable for use on aluminium and other soft metals. 
 

Ultraclean SPX

: A strong alkaline detergent for removal of tough grease and heavy 

carbon deposits. Not suitable for use on aluminium and other soft metals. 
 

Ultraclean PH

: A strong acidic based detergent for heavy descaling, light rust removal 

and metal brightening. Not suitable for use on aluminium and other soft metals. 
 

Ultraclean CTA

: An acidic based detergent for descaling, degreasing and brightening 

of metals. Fair compatibility with aluminium. 
 

Ultraclean RI: 

Rust inhibitor for corrosion prevention of ferrous metals. 

 

Ultraclean Test Kit: 

A sample pack of 1L each of the Ultraclean: SA, M2, CS, CBX, SPX 

and PH. 
 

 

 

Содержание ARGON

Страница 1: ...Ultrasonic Cleaning System Operator Instruction Manual...

Страница 2: ......

Страница 3: ...nspecting the filters 11 Technical Information 13 Ultrasonic cleaning detergents 14 Ultrasonic cleaning good practice 15 Maintenance 16 Disposal of this ultrasonic cleaning system 16 Returning equipme...

Страница 4: ...not place hands or fingers in the tank Care should be taken when operating the ultrasonic cleaning system at higher temperatures as external surfaces may become hot Never use toxic flammable acidic c...

Страница 5: ...cables between the tank and electrical cabinet in suitable open frame cable trays keeping a separation between the sonics and sensor cables Do not let the cables rest on the floor creating a trip haz...

Страница 6: ...t black hinged panel There is an isolation valve on the input and output side of the dual filter system Please ensure these valves handles are in line with the pipework as this is the open position Be...

Страница 7: ...se ensure the fluid reaches over the top level sensor or the ultrasonics will not operate Add the required dose of detergent see pg 14 Quick Operating Guide Switch on the machine via the switch at the...

Страница 8: ...this screen is displayed the buttons are inoperative This is normal as the machine is running through its start up routine and checking all internal systems are working correctly The top line of the d...

Страница 9: ...re set cycle If the unit is a wash rinse type the cycle will now run indicated by the Running message for its pre set cycle time and any re circulation if fitted will also run once at the cycle start...

Страница 10: ...l also appear if the fluid temperature is below the minimum temperature During this warm up period the screen will show a Heating message The cycle can be aborted at any time by the operator by pressi...

Страница 11: ...mp The temp is under the min temperature 3 Over Temp The temp is over the max temperature 4 Operator The operator cancelled the cycle 5 Sensor fail The temperature sensor is faulty 6 Power fail There...

Страница 12: ...aced into a drain Step 2 Turn the tap until it is in its open position Step 3 Allow the liquid to drain Step 4 Close the tap when the tank is completely drained Step 5 Wipe the inside of the tank to r...

Страница 13: ...damage the pump The tank process and weir areas do not need to be emptied to change the filters Step 1 Ensure that the drip tray is in place below the filter housings Step 2 Turn both isolation valve...

Страница 14: ...t filter is the coarse filter higher value uM filter and the left filter is the fine filter lower value uM filter when replacing the filter elements Step 8 Repeat the same process for the second filte...

Страница 15: ...sed the ultrasonic cleaner is ready for use The effect of heat Heating the liquid in the ultrasonic cleaner will aid the cleaning process Normally a temperature of between 30 to 70 C is sufficient to...

Страница 16: ...ents Ultraclean CS Moderate grease and heavy contaminant removal for industrial cleaning applications Not suitable for use on aluminium and other soft metals Ultraclean CBX An alkaline detergent for h...

Страница 17: ...ergents Ultrasonic cleaning requires the presence of a cleaning detergent to clean effectively See page 14 for more information Rinsing Components should be rinsed with clean running water prior after...

Страница 18: ...rmation Tel 44 0 845 330 4238 Email service ultrawave co uk Disposal of this ultrasonic cleaning system At the end of its useful life please ensure that you dispose of this product in accordance with...

Страница 19: ...far as this wear is not caused by structural failures The warranty does not cover defects or failures arising out of non observance improper or faulty maintenanceorfaultyrepairorbyalterationscarriedou...

Страница 20: ...Argon Ultrasonic Cleaning System However on many occasions it is possible that the problem can be rectified by the operator The unit fails to turn on no display is shown Check that the system is plug...

Страница 21: ...g is now 80 decibels There is also an exposure limit value of 87 decibels taking account of any reduction in exposure provided by hearing protection above which workers must not be exposed To help you...

Страница 22: ...202 2000 Ergonomics of the thermal environment Temperatures of touchable hot surfaces Guidance for establishing surface temperature limit values in production standards with the aid of EN 563 1994 Saf...

Страница 23: ...k can be obtained from Ultrawave For details of testing validation servicing and Service contracts contact Ultrawave or its agent There are no user serviceable parts inside All service and repair shou...

Страница 24: ...Details Next service due Date Cycle count Engineer Details Next service due Date Cycle count Engineer Details Next service due Date Cycle count Engineer Details Next service due Date Cycle count Engin...

Страница 25: ......

Страница 26: ...5201 05 Date of Issue December 2021 Ultrawave baths are manufactured in the United Kingdom Ultrawave baths are manufactured to exacting standards and conform to international standards www ultrawave c...

Отзывы: