SAFETY REQUIREMENTS 

 

All personnel must read this user guide before attempting to operate, maintain, or service 
the UltraSonic LLC Cleaning Equipment. 

 

HAZARDS 
 

 

High voltages are present, ALWAYS disconnect unit from power source before 
attempting any maintenance or service procedure. 

 

 

Hot water; do not place unprotected hands in tank.  Use baskets with lifting 
mechanism to insert or remove parts from tank. 

 

 

Read MSDS sheet for cleaning agents recommended for the system.  Note the 
requirements for personal protection listed on the MSDS. 

 

 

Make sure equipment is properly installed in accordance with all electrical codes. 

 

 

Never operate this equipment in an ungrounded condition. 

 

 

Never attempt to perform maintenance when cleaning solution is hot. 

 

 

Never open equipment or attempt service/warranty related repairs without first 
contacting UltraSonic LLC for safe and proper procedures. 

 

 
SAFE OPERATION 
 

 

Do not immerse hands or other body parts in the ultrasonic tank.  Cleaning agents and 
contaminants can cause skin irritation and exposure to high intensity ultrasonic 
energy should be avoided. 

 

 

Do not operate system using volatile, explosive, combustible or acidic liquids (pH 
less than 7).  Unauthorized cleaning agents, not approved by UltraSonic LLC, will 
invalidate warranty and may cause damage to system. 

 

 

Parts may be gently rested on the rack on the bottom of the tank. Avoid 
dropping parts on this which may result in tank damage and void your 
warranty. 

 

 

Do not operate the system unless the tank is full.  Operating at less than full capacity 
may result in damage and void the warranty. 

Содержание Ultra 3800FLT

Страница 1: ...00FLT 220v 240V 2 Voltage Supply to Machine L1 to L2 ___________ L1 to Ground ____________ L2 to Ground ___________ UltraSonic LLC 1200 Ferris Road Amelia Ohio 45102 Tel 513 502 9746 Fax 513 436 1527...

Страница 2: ...on Never attempt to perform maintenance when cleaning solution is hot Never open equipment or attempt service warranty related repairs without first contacting UltraSonic LLC for safe and proper proce...

Страница 3: ...in the tank longer than necessary This can result in erosion of the part surface and or the bottom of the tank Do not allow moisture to build up inside the unit this can cause electrical shorts and c...

Страница 4: ...l Ultrasonic lights will display green Operating temperature is pre set 150 F on the TEMP CONTROL Initial heat up time using cold water is approximately two hours For automatic heating see Programmer...

Страница 5: ...UltraSonic LLC Model Ultra 3800FLT 5 Control Panel Control Panel Functions...

Страница 6: ...er 6 Filtration Manual Start Stop Filtration Timer 7 Auxiliary Manual Start Stop Timer 8 Up Agitation Table 9 Down Agitation Table 10 Menu Machine Timers and Settings See Program Settings 11 Up Naviga...

Страница 7: ...Manual Start Stop Ultrasonic Operation Agitation Button Manual Start Stop Agitation Operation Filtration Button Manual Start Stop filtration Operation Aux Button Manual Start Stop Auxiliary Operation...

Страница 8: ...desired Menu Option press Menu Button until edit position is reached then use Up and Down Buttons to edit selection press Menu button to save settings Temperature Set Press Menu Button until Temp Cont...

Страница 9: ...n Menu Press UP Button until Day AUX Control press Menu Button until Day Time On Off use Up Down Buttons to set ON or OFF Press Menu Button to reach Day Set press Menu button again to set Days use Up...

Страница 10: ...UltraSonic LLC Model Ultra 3800FLT 10...

Страница 11: ...UltraSonic LLC Model Ultra 3800FLT 11...

Страница 12: ...UltraSonic LLC Model Ultra 3800FLT 12...

Страница 13: ...UltraSonic LLC Model Ultra 3800FLT 13...

Страница 14: ...in tank is slowed Most users regularly replace their filter each month to avoid any decrease of flow Solution should be replaced regularly to avoid a drop in cleaning performance that will result from...

Страница 15: ...ents Follow installation instructions listed earlier for refilling and start up procedures MAXIMIZING ULTRASONIC PERFORMANCE Temperature Temperature has a dramatic effect on the cleaning performance a...

Страница 16: ...at a time using shorter cleaning cycles Contaminated Solution As contaminants build up in the solution the ultrasonic performance drops The cavitation bubbles waste their energy imploding on the conta...

Страница 17: ...LING ULTRASONIC LLC 513 502 9746 SPECIAL NOTE PLEASE RETAIN ORIGINAL SHIPPING CRATE Our service tech will help troubleshoot any problem and instruct user on the safe and proper procedures for repairs...

Страница 18: ...n no case shall UltraSonic LLC be responsible for any incidental or consequential damages This warranty does not apply to Equipment or components subjected to misuse improper installation alteration m...

Страница 19: ...nd ________ Voltage Supply to Machine with heaters on L1 to L2 ___________ L1 to Ground _________ L2 to Ground ________ I have received a copy of the Operational Instruction Manual I am aware that all...

Отзывы: