3 Appendix
A
3.1 Communication Port
The communication port is a direct I2C Connection to the internal fuel gauge. The
fuel gauge is programmed at the factory for the specifics of the MKM chemistry.
There are a few correction factors needed to use the data stored in the fuel gauge.
Voltage must be multiplied by 8.
Current must be multiplied by 72 for a URB0001, 44 for a URB0003.
Capacity in Ahr must be multiplied by 72 for a URB0001, 44 for a URB0003.
All registers in the fuel gauge are available on the datasheet for the MAXIM 17047
Model M3 Fuel Gauge.