31
Installation
Reference page
<MAINTENANCE>
POWER LOSS LIST
ALARM LIST
ALL MENU INITIALIZE
POWER LOSS LIST CLEAR
ALARM LIST CLEAR
<REPEAT REC TIMES>
0
<ELAPSED TIME>
0H
ALL MENU INITIALIZE
Turn the SHUTTLE RING
then all MENU will be
initialized.
MAINTENANCE
Displaying the power loss list
(POWER LOSS LIST)
page 15
Displaying the alarm list (ALARM
LIST)
page 15
Initializing all menu settings (ALL MENU INITIALIZE)
All menus will be initialized except timer programs.
1. Press MENU button.
•
<MAIN MENU> appears.
2. Turn JOG to select MAINTENANCE and turn SHUTTLE to
the right.
•
<MAINTENANCE> menu appears.
3. Turn JOG to select ALL MENU
INITIALIZE and turn SHUTTLE to
the right.
•
<ALL MENU INITIALIZE> menu
appears.
4. Turn SHUTTLE to the left.
•
The setting of all menus (except TIMER PROGRAM) will
return to its initial setting.
5. Press MENU button.
•
The day and present time display appears on screen.
Clearing the power loss list (POWER LOSS LIST CLEAR)
page 15
Clearing the alarm list (ALARM LIST CLEAR)
page 15
Displaying number of tape use (REPEAT REC TIMES)
page 16
Displaying the elapsed time of VCR (ELAPSED TIME)
page 16
REAR TERMINAL
Setting the operation mode of the
CALL OUT terminal (CALL OUT)
Sets the mode of call signal output from
the CALL OUT terminal. If any
abnormalities occur with the VCR
during recording, the call signal is
output from the CALL OUT terminal on
the rear panel regardless of CALL OUT
setting.
WRNG•TAPE END : The VCR outputs a call signal when the
tape reaches its end during recording or
when a malfunction occurs during recording.
The VCR’s function when the tape ends
depends on the setting of TAPE END in
FIRST TIME SET UP menu (
next page).
WRNG•REMAIN
: The VCR outputs a call signal when a
malfunction occurs during recording or when
the tape has approximately 9 minutes (at 6H
mode) left during recording.
WRNG
: The VCR outputs a call signal only when a
malfunction occurs during recording.
Setting the recording mode and frequency division ratio
(CLOCK OUT)
Sets the recording mode and the frequency division ratio of clock
pulse output from the CLOCK OUT terminal.
• Setting the recording mode during the clock pulse output
REC
: When recording in any mode.
T/L REC
: When recording in time-lapse mode (L18H-128H
or 0H).
• Setting the frequency division ratio of the clock pulse output.
When JOG is turned, the display will be switched in the order
of 1
2
3
4
5
10
15
20
25
30
50
60
F (field)
1
...
The numbers 1 to 60 indicate the number of frames at 6H
recording mode and the number of fields at time lapse
recording modes. (One frame consists of two fields.) When
set to F (field), one field is selected.
Setting the operation mode of the MODE OUT terminal
(MODE OUT)
A mode signal is output under the following circumstances.
REC
: During recording.
PLAY
: During playback.
POWER
: While the VCR is turned on.
TAPE IN
: When a tape is inserted in the VCR.
TAPE REMAIN
: When the tape has approximately 9 minutes (at
6H mode) left.
CLOCK ADJ
: When the clock indicates “00(min.):00(s)”.
(The signal is output for 1 second only.)
Setting the operation mode of REC IN terminal (REC IN)
SERIES
: Recording starts when the REC IN terminal
is grounded.
REC-START/STOP : Recording continues while the REC IN
terminal is grounded. If the signal is input
for a short period, the VCR may not start
recording.
SYNC REC
: The video signal from the multiple of 3 or 5
cameras can be recorded separately by
connecting a switcher (
page 14 for the
menu setting and page 27 for the
connection).
Setting the number of fields in oneshot recording (ONE
SHOT•FIELD)
Sets the number of recorded fields in the oneshot recording
mode. When JOG is turned, the display will be switched in the
order of 1
2
3
4
5
10
20
30
1
...
Setting the interval time in the oneshot recording (ONE
SHOT•INTERVAL)
Sets the interval time in the oneshot recording mode. When JOG
is turned, the display will be switched in the order of SHOT
10S (second)
15S
30S
45S
1M (minute)
2M
3M
SHOT
...
<REAR TERMINAL>
CALL OUT
WRNG•TAPE END
CLOCK OUT
REC- 1
MODE OUT
REC
REC IN
SERIES