![Ultrak KD6 Z-SERIES Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/ultrak/kd6-z-series/kd6-z-series_installation-tips-and-maintenance_3520762011.webp)
518854-2960-D
5
KDMU040013
7/20/01
Problem
Possible Solution
g. Scan drifts in one
direction (up, down, left,
right).
Joystick on JPD series controller out of adjustment. Recenter joystick
and verify coordinate settings.
OPT> 3> 3
View coordinate display of joystick on LCD display.
OPT> 3> 2
Display shows:
P-###
T-###
Z-###
### should be 128
±
10.
If this does not correct problem, consult factory.
h. Scan is jerky.
1.
Verify both data lines are connected.
2.
A motor may be defective or the wiring to the motor may be
broken.
6.1
REMOVING THE BOTTOM DOME FROM AN INDOOR TOP DOME
Always handle the dome from the outside surface.
Pendant Dome
1.
Remove power to the unit.
2.
Press in gently on the bottom dome and pull the dome down.
Dropped Ceiling or Hard Ceiling Dome
1.
Remove power to the unit.
2.
Rotate the bottom dome counterclockwise and lower the dome. If the unit is installed for CE
compliance, remove the screw in the trim ring, then rotate the bottom dome.
6.2
REMOVING THE PAN AND TILT ASSEMBLY
Pendant Dome
1.
Remove the power to the unit.
2.
Remove the dome from the mount by removing the three M4/8 screws that secure the top
dome to the mount.
3.
Remove the bottom dome.
4.
Hold on to the pan and tilt assembly
and remove the three (3) nuts and lockwashers from
the mounting plate on the top dome. The three (3) nuts secure the pan and tilt assembly to
the top dome.
Dropped Ceiling or Hard Ceiling Dome
1.
Remove the power to the unit.
2.
Remove the bottom dome.
3.
Remove the locking screw on the scan mounting bracket in the top can (refer to the
illustrations on pages 11 and 12).
4.
Loosen (do not remove)
the two retaining screws in the top can.
5.
Rotate the mounting bracket counterclockwise so the retaining screws are aligned with the
large key holes and lower the unit.
7.0
MAINTENANCE
Every three months, perform the following:
1.
Make sure the mount is secured.
2.
Make sure the dome is secured to the mount.
3.
Inspect all connecting cabling for deterioration or other damage.
4.
Clean the domes (only if required) using the procedure defined for your dome type.