6.  Remove the rear of the housing from the base by unscrewing

the two Phillips panhead screws. 

(See Figure 1)

 
 
 
 
 
 
 
 
 
 
7.  Use these screws to replace the rear with the blower unit,

being careful not to damage the wiring to the attached circuit
board. 

(See Figure 2)

8.  Reattach the standard silver camera mounting plate to the

shelf extending from the rear of the housing. Align the holes
and secure using the two flathead screws mentioned in step
5. 

(See Figure 2)

9.  Next, mount the blower circuit board on the camera mounting

plate. To do this, first place the two plastic spacers on the
two holes near the rear of the plate. Set the blower circuit
board on top of the spacers, aligning the holes and keeping
the wiring on the same side. Insert the small Phillips panhead
screws and secure the assembly. 

(See Figure 2)

10. Connect the

external power
supply 

(not

included) 

to the

circuit board. The
recommended
power supply is 24
Vac, 50 VA. 

(See

Figure 3)

11.  To mount your camera, consult the section Camera

Mounting for HEB Series Housings on page 7. Begin with
step 5. Then see UL-WB+BJ & UL-WBM Wall Bracket
Mounting on page 10.

 

 

FIGURE 2

 

FIGURE 3

Содержание HEB10

Страница 1: ...CAMERA ENCLOSURES WITH OPTIONAL SUNSHIELD HEATER AND BLOWER KITS AND MOUNTING BRACKET INSTALLATION INSTRUCTIONS Worldwide Support Center 1301 Waters Ridge Drive Lewisville TX 75057 800 796 2288 972 3...

Страница 2: ...REPRODUCED BY ANY MEANS WITHOUT WRITTEN PERMISSION FROM ULTRAK THE INFORMATION IN THIS PUBLICATION IS BELIEVED TO BE ACCURATE IN ALL RESPECTS HOWEVER ULTRAK CANNOT ASSUME RESPONSIBILITY FOR ANY CONSE...

Страница 3: ...3 HEB10 BK BLOWER KIT WITH HEB10 HK HEB12 HK HEATER KIT INSTALLATION 6 2 4 CAMERA MOUNTING FOR HEB SERIES HOUSINGS 8 2 5 HEB10 SS HEB12 SS SUNSHIELD INSTALLATION 10 2 6 UL WBM UL WB BJ WALL BRACKET M...

Страница 4: ...0 and HEB12 camera housing series feature Contemporary design Die cast and extruded aluminum construction Adjustable mounting track Hinged removable body for easy servicing Compression cable fittings...

Страница 5: ...the two Phillips panhead screws located midway up the rear of the housing Retain the screws and their black rubber gaskets which were left in the holes on the rear of the housing See Figure 1 3 By sl...

Страница 6: ...unt the blower circuit board on the camera mounting plate To do this first place the two plastic spacers on the two holes near the rear of the plate Set the blower circuit board on top of the spacers...

Страница 7: ...HEB10 03 and HEB12 03 add a blower kit to this package 1 If applicable remove the sunshield by sliding it off the main housing unit 2 Loosen the two Phillips panhead screws located midway up the rear...

Страница 8: ...plate is secured to the shelf that extends from the rear of the housing unit See Figures 4 5 6 Connect the external power supply not included to the circuit board The recommended power supply is 24 Va...

Страница 9: ...ews and their black rubber gaskets which were left in the holes on the rear of the housing See Figure 7 3 By sliding the housing shell away from the rear portion of the unit separate the housing into...

Страница 10: ...screws on the heater circuit board Unscrew them and remove the board from the mounting plate With the two plastic spacers already over the small holes on the mounting plate set the blower circuit boa...

Страница 11: ...t 2 Loosen the two Phillips panhead screws located midway up the rear of the housing Leave the screws intact in the rear portion of the housing See Figure 10 3 By sliding the housing shell away from t...

Страница 12: ...the cable through the compression glands and make all of the necessary electrical connections as described in the instructions that accompanied the camera Be sure that the compression glands are firm...

Страница 13: ...camera has been installed and the housing has been reassembled See Camera Mounting for HEB Series Housings on page 7 install the sunshield by sliding it along the top of the housing unit See Figure 1...

Страница 14: ...hannel Position the nuts approximately 2 3 8 from one another See Figure 15 3 Place the housing onto the mount aligning the holes Insert the two provided bolts through the mount and into the nuts Secu...

Страница 15: ...h heater blower 3 5 x 3 3 x 9 in 88 9 x 83 8 x 229 mm HEB12 3 5 x 3 3 x 12 in 88 9 x 83 8 x 305 mm HEB12 with heater blower 3 5 x 3 3 x 11 in 88 9 x 83 8 x 279 mm Viewing Area WxH 3 5 x 3 1 in 88 9 x...

Страница 16: ...OFF t o C 20 o C 3 o C t o F 68 o F 5 o F Dimensions WxHxD 5 5 x 5 0 x 3 7 in 139 x 128 x 97 mm 3 3 HEB10 HK HEB12 HK HEATER SPECIFICATIONS Power Supply 24Vac Power Consumption 40W Heater ON t o C 14...

Страница 17: ...od Friction Controlled through Bolt Tightening Wall Mounting Method 4 Holes for Fasteners of a Suitable Size and Type Mount to a Secure Solid Surface Enclosure Mounting UL WBM 2 Allen Bolts UL WB BJ 2...

Страница 18: ...15 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 19: ...16 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 20: ...17 FORM 1047 REV 11 96...

Отзывы: