Ultraflux Minisonic ISD Скачать руководство пользователя страница 3

NT216C GB1 

 

3 / 26 

SUMMARY: 

 

– Typical Applications:  

Measurement principle 
Sound velocity in petroleum products 
Pig detection in Gas pipes   

 

– Composition of a measurement point . 

Certification 
Applicable standards  
MiniSonic limitations 

 

– Ergonomics and dimensions 

Wall mounted industrial Version. 
Ex d, ATEX certified version. 

 

– Wiring diagram. 

 

– Converter Assembling Instructions. 

Mechanical installation. 
Electrical wiring. 

 

– Probe(s) Installation.  

 

– Setting and commissioning.  

 

– Detailed Menu layout: 

   

Measurement Display Menu 

   

Calibration Allowed Menu 

   

Probe and Echo settings Menu. 

   

Pipe and Product settings Menu  

   

Sphere or Pig-sig settings menu 
General Parameters / Current Output & Relays Menu 

   

Test Menu  

   

Factory settings ( if allowed )  

 

–  Recommendations – Final checks and tests  

 
10 - Investigations 

– Spare parts.  

 
11 

– Appendix  

Содержание Minisonic ISD

Страница 1: ...detector Minisonic ISD Interface pig and sphere detector B timent TEXAS ragny Parc 9 All e Rosa Luxemburg 95610 RAGNY FRANCE T l 33 0 1 30 27 27 30 Fax 33 0 1 30 39 84 34 www ultraflux net Ultraflux N...

Страница 2: ...2 and 2000 2 for dual chord flow metering 600 B and 2000 B for dual pipe flow measurement configurations Speed 1 2 are devices for open channel flow velocity measurements This manual is specifically...

Страница 3: ...certified version 4 Wiring diagram 5 Converter Assembling Instructions Mechanical installation Electrical wiring 6 Probe s Installation 7 Setting and commissioning 8 Detailed Menu layout Measurement...

Страница 4: ...und velocity is representing the data to be followed up For instance there is a very interesting relation with sulfuric acid at concentrations between 75 and 100 Same any ionized salt changes sound sp...

Страница 5: ...nside the product under the actual conditions of pressure and temperature More precisely time t between emission and receipt is equal to t 2 x time in probe 2 x time in wall 2 x time in product That i...

Страница 6: ...ction capability Sometimes such a divergence becomes an advantage and permits to detect a change that is called interface between two successive products that have the same density Meanwhile end user...

Страница 7: ...ty m s 3 B concentration in c B Pure product B Pure product A C C B C A Sound velocity 50 0 25 75 100 Theoretical relation curve between sound velocity and density 1 bar 15 C Most of usual pure refine...

Страница 8: ...ssure P and Temperature T on sound velocity We remind that P and T are also influencing actual density Pressure influence Global Coefficient varies with density range Here we have from 0 4 up to 0 7 m...

Страница 9: ...tection by pig noise hearing some companies call such detectors Ultrasonic can work with a new foam pig but this noise can be lower than ambient noise with a used pig with a risk of no detection Thus...

Страница 10: ...ncerning high voltage human safety risks N A Only low voltage 60 V Concerning EMC EN 61000 EN 55022 et EN 50204 Concerning tightness IP EN 60529 Concerning ATEX Directive 94 4 CE EN 60079 0 General ru...

Страница 11: ...htening must comply with the IP 67 preservation The unit can be wall mounted or attached to the pipe but its small size and shape permit to mount it directly on a DIN rail inside an electrical enclosu...

Страница 12: ...two glands near the front are reserved for probe cable s When only one is used please keep he other one closed and tight To do the internal wiring on MiniSonic it is necessary to remove the front of t...

Страница 13: ...Ex d version the board is inverted access is from underneath The removable connectors are useful for wiring and maintenance purposes V 100 v I 0 1 A P 2 W 0 5 to 1 5 mm P 2 Watt 10 to 30 V 9 to 18 V...

Страница 14: ...20 mA analog outputs BR 2 terminals 11 to 14 Multi pair cables These are independent outputs galvanically insulated in respect to each other but also with respect to the other MiniSonic circuits and...

Страница 15: ...to decide if two probes mounted as a barrier would be better large pipe and very viscous oil By default we use F 1 MHz Particular attention will be paid to cleaning the pipe at the probe s location Re...

Страница 16: ...Refer to the manual supplied with the software CD ROM The fields of the main values to be entered are listed below under Heading 8 The software offers extended configuration possibilities The software...

Страница 17: ...Plus warning messages if any Or the Sphere Counter Last Sphere for a PSD Gains mode and value and I Q quality indicator If I Q is less than 33 the last Measurement cycle is rejected Physical measurem...

Страница 18: ...which you want action to take place An operation will be requested allowing a provisional code to be calculated A second press on will provide access to the existing Languages choice field 8 3 Probe...

Страница 19: ...range This range is Co Delta C Co can be set from 200 to 2000 m s Delta C can be set up to 500 m s Enter it wider than typical values at 15 C 1 bar to take in accounts P T effects These values will de...

Страница 20: ...d from the flow velocity Correct data range must be entered as follows Choice of the data to calculate velocity V flow velocity then m s entry Q flow value then m3 h entry Entry of V min or Q min Entr...

Страница 21: ...output 1 Current output is reserved to the Interface detection information Set in relation with density range Settings of current output 2 Current output 2 can copy the Ultrasonic signal result Gain A...

Страница 22: ...nds to a positive logic No supply relays are opened All OK fault relay is closed Sphere passage relay closes during 5 seconds Sound speed below threshold relay closed First LCD screen in place of soun...

Страница 23: ...to don t valid an echo loss as a sphere or a pig FINAL CHECKS AND TESTS Once installation connections and parameters have been set up several possible situations may arise Case 1 The measurement disp...

Страница 24: ...iniSonic powered up Check with a voltmeter Has it failed If yes the only solution is to call in our after sales service If the MiniSonic displays INIT constantly attempt a power cutoff then re energiz...

Страница 25: ...Volt Ground PT 2 Synchro Positive edge 0 to 5 Volt PT 1 Selection windows Echo must be inside PT 3 Emission Reception transit time PT 0 0 Volt Or a MiniSonic ISD P portable device Or measuring instru...

Страница 26: ...NT216C GB1 26 26 11 APPENDIX EXAMPLE OF SETTING FILE FOR A 12 PIPE...