PREAMBLE: 

 

Thank you for choosing Ultraflux to help your 

petroleum product quality survey

 during  

pumping operations by pipe-line or other process as pipe cleaning or product separators 
detection . 
 
We offer a new range of 

detectors backed by 30 years’ expertise and experience using 

Ultrasonic techniques.  
 

 UF 801-P family, high features portable flow meters, with integral loggers and 

signal analysis functions. 

 
   

 UF 8xx families of fixed flowmeters, applications include 

L - Liquids, 
G - Gas,  
MC: Multi-chord applications, Liquid and Gas flow measurement, 
CO / RV: Open Channel and River Flow Measurement. 

 
   

 The MiniSonic family with:  

– Portable Metering with also a two pipes or dual path version P-B 

600/2000, single-channel fixed flowmeters, 
600-2 and 2000-2, for dual-chord flow metering, 
600-B and 2000-B, for dual-pipe flow measurement configurations,  
Speed 1 & 2 are devices for open channel flow velocity measurements. 

 
 
This manual is specifically concerned by the Interface & Pig or Sphere Detection and has 
been drafted to guide you in the stages of installation and commissioning these MINI-ISD 
& PSD. 
 
Other documents and tools are available on electronic format only: 
 

> A training manual concerning ultrasonic measurements, reference 

NT 122

  

 

> A guide about the use of our software in the Windows environment Ref 

NT 203

 

 

> The PC software specific to your application Ref 

LS 600W-ISD

 _version *** with 

an interconnection cord to the PC. 

 
> The JBUS communication protocol with its address table 

NT 202

 

 
Other  devices  concern  the  interface  detection  when  Pressure  or  Temperature  effects 
need to be corrected: the M 1189 

– S (Analog) or the 

M 1189-N

 (Digital) or any module 

having implemented functions (as 

BRIO

 

…). 

 
 

Содержание Minisonic ISD

Страница 1: ...detector Minisonic ISD Interface pig and sphere detector B timent TEXAS ragny Parc 9 All e Rosa Luxemburg 95610 RAGNY FRANCE T l 33 0 1 30 27 27 30 Fax 33 0 1 30 39 84 34 www ultraflux net Ultraflux N...

Страница 2: ...2 and 2000 2 for dual chord flow metering 600 B and 2000 B for dual pipe flow measurement configurations Speed 1 2 are devices for open channel flow velocity measurements This manual is specifically...

Страница 3: ...certified version 4 Wiring diagram 5 Converter Assembling Instructions Mechanical installation Electrical wiring 6 Probe s Installation 7 Setting and commissioning 8 Detailed Menu layout Measurement...

Страница 4: ...und velocity is representing the data to be followed up For instance there is a very interesting relation with sulfuric acid at concentrations between 75 and 100 Same any ionized salt changes sound sp...

Страница 5: ...nside the product under the actual conditions of pressure and temperature More precisely time t between emission and receipt is equal to t 2 x time in probe 2 x time in wall 2 x time in product That i...

Страница 6: ...ction capability Sometimes such a divergence becomes an advantage and permits to detect a change that is called interface between two successive products that have the same density Meanwhile end user...

Страница 7: ...ty m s 3 B concentration in c B Pure product B Pure product A C C B C A Sound velocity 50 0 25 75 100 Theoretical relation curve between sound velocity and density 1 bar 15 C Most of usual pure refine...

Страница 8: ...ssure P and Temperature T on sound velocity We remind that P and T are also influencing actual density Pressure influence Global Coefficient varies with density range Here we have from 0 4 up to 0 7 m...

Страница 9: ...tection by pig noise hearing some companies call such detectors Ultrasonic can work with a new foam pig but this noise can be lower than ambient noise with a used pig with a risk of no detection Thus...

Страница 10: ...ncerning high voltage human safety risks N A Only low voltage 60 V Concerning EMC EN 61000 EN 55022 et EN 50204 Concerning tightness IP EN 60529 Concerning ATEX Directive 94 4 CE EN 60079 0 General ru...

Страница 11: ...htening must comply with the IP 67 preservation The unit can be wall mounted or attached to the pipe but its small size and shape permit to mount it directly on a DIN rail inside an electrical enclosu...

Страница 12: ...two glands near the front are reserved for probe cable s When only one is used please keep he other one closed and tight To do the internal wiring on MiniSonic it is necessary to remove the front of t...

Страница 13: ...Ex d version the board is inverted access is from underneath The removable connectors are useful for wiring and maintenance purposes V 100 v I 0 1 A P 2 W 0 5 to 1 5 mm P 2 Watt 10 to 30 V 9 to 18 V...

Страница 14: ...20 mA analog outputs BR 2 terminals 11 to 14 Multi pair cables These are independent outputs galvanically insulated in respect to each other but also with respect to the other MiniSonic circuits and...

Страница 15: ...to decide if two probes mounted as a barrier would be better large pipe and very viscous oil By default we use F 1 MHz Particular attention will be paid to cleaning the pipe at the probe s location Re...

Страница 16: ...Refer to the manual supplied with the software CD ROM The fields of the main values to be entered are listed below under Heading 8 The software offers extended configuration possibilities The software...

Страница 17: ...Plus warning messages if any Or the Sphere Counter Last Sphere for a PSD Gains mode and value and I Q quality indicator If I Q is less than 33 the last Measurement cycle is rejected Physical measurem...

Страница 18: ...which you want action to take place An operation will be requested allowing a provisional code to be calculated A second press on will provide access to the existing Languages choice field 8 3 Probe...

Страница 19: ...range This range is Co Delta C Co can be set from 200 to 2000 m s Delta C can be set up to 500 m s Enter it wider than typical values at 15 C 1 bar to take in accounts P T effects These values will de...

Страница 20: ...d from the flow velocity Correct data range must be entered as follows Choice of the data to calculate velocity V flow velocity then m s entry Q flow value then m3 h entry Entry of V min or Q min Entr...

Страница 21: ...output 1 Current output is reserved to the Interface detection information Set in relation with density range Settings of current output 2 Current output 2 can copy the Ultrasonic signal result Gain A...

Страница 22: ...nds to a positive logic No supply relays are opened All OK fault relay is closed Sphere passage relay closes during 5 seconds Sound speed below threshold relay closed First LCD screen in place of soun...

Страница 23: ...to don t valid an echo loss as a sphere or a pig FINAL CHECKS AND TESTS Once installation connections and parameters have been set up several possible situations may arise Case 1 The measurement disp...

Страница 24: ...iniSonic powered up Check with a voltmeter Has it failed If yes the only solution is to call in our after sales service If the MiniSonic displays INIT constantly attempt a power cutoff then re energiz...

Страница 25: ...Volt Ground PT 2 Synchro Positive edge 0 to 5 Volt PT 1 Selection windows Echo must be inside PT 3 Emission Reception transit time PT 0 0 Volt Or a MiniSonic ISD P portable device Or measuring instru...

Страница 26: ...NT216C GB1 26 26 11 APPENDIX EXAMPLE OF SETTING FILE FOR A 12 PIPE...