Installation manual
ULTRAFLEX
page 34
of 39
- ZTF SYSTEM
Proceed as follows:
1. Move the cylinder towards the end of stroke on the
starboard side (see picture 1) by steering the tiller
handle in the same way as during navigation.
NOTICE
The by-pass knob must be fully loosened (system in by-
pass mode).
2. Start the Bubble Buster by pressing the switch shown
below.
3. The oil will start circulating into the system and, from the two transparent hoses connected to the cylinder,
oil together with air will start flowing.
4. Without moving the tiller handle and, therefore, the cylinder, wait for a couple of minutes until the transparent
hoses show only oil with very few air bubbles.
5. Move the cylinder slowly towards the opposite side (port, see picture 2), by always acting on the tiller handle.
4.2.2 Filling and purging operation
TOWARDS
STARBOARD
5. Loosen the release nuts (3) for enabling the oil to pass through. Do not unscrew more than one turn and a
half. Use a 16 mm wrench.
6. Connect the battery clamps: the red clip to the positive terminal and the black one to the negative terminal.
CAUTION
Only 12 Vdc power supplies are allowed.
1
3
Содержание ND1-MM
Страница 37: ...ZTF SYSTEM page 37 of 39 Installation manual ULTRAFLEX NOTES ...
Страница 38: ...Installation manual ULTRAFLEX page 38 of 39 ZTF SYSTEM NOTES ...
Страница 39: ...ZTF SYSTEM page 39 of 39 Installation manual ULTRAFLEX NOTES ...
Страница 40: ...ULTRAFLEX S p A 16015 Casella Genova Italia Via Crose 2 ...