The cooling air for the refrigerant condenser will be sucked
in at the front panel (fig. 2). This area must be kept free
and not be obstructed.
If necessary, the cooling air may be led to the CA-dryer
from outside through wall openings.
The cooling air outlet is positioned at the top of the unit
(fig. 2). Ensure a free air outlet and do not obstruct the
outlet of the cooling air.
If the CA-dryer is connected to an exhaust trunk, an
additional fan must be installed, depending on the di-
mensions of the trunk.
The connection must be executed acc. to marking at the
CA-dryer (fig. 2).
For service purposes the installation of a bypass line is
recommended (additional equipment).
Attention!
Before mounting the CA-dryer, welding residual, rust or
other pollution must be removed from the pipelines to be
connected. If pollution cannot be excluded, proper filter
system must be installed
The compressed air pipes must be installed stress-free.
Expansion joints are recommended in case of vibrations
and pulsations.
Part 2
Installation
2.3.1
Version air cooled
Fig. 2: Installation of the
CA-dryer (air cooled)
2.4
Compressed air con-
nection
min. 32 in
Direction of suc-
tion cooling air
min. 32 in
Outlet
cooling air
ö
ö
CA-outlet
CA-inlet
!