Menu 3- Starter Settings
Ignition
ON-OFF-ON-OFF-ON
Press & Release
Program Button
Press
Start Button
Setting 1 Special Door Lock/Unlock Operations (Factory Alarm Rearm)
.
1) Type 1
1 Flash/Honk
Unlock pulse before start. Lock pulse after start and on shutdown.
2) Type 2
2 Flashes/Honks
Lock pulse ONLY after remote start shutdown.
*3) Type 3
3 Flashes/Honks
Default Lock/ Unlock Pulses.
Press & Release the Program Button 1 Time
(Setting 1) Confirmed with 1 LED flashes.
Press & Hold the Program Button
until the appropriate # of park lights/horn (optional) honks, then release.
Press & Release the Program Button
to proceed to the next step.
Setting 2 With 11 pin Connector- Gas/Diesel Mode (Auxiliary Connector Pin 12)
1) (+) Input
1 Flash/Honk
(+) Glow Plug input. Waits maximum 30 seconds then starts.
2) Time Delay
2 Flashes/Honks
Waits for approximately 15 seconds then remote starts.
*3) Gas/ (-) Input
3 Flashes/Honks
Waits 2 seconds to start if no diesel input is detected.
Press & Release the Program Button 2 Times (Setting 2)
Confirmed with 2 LED flashes.
Press & Hold the Program Button
until the appropriate # of park lights/horn (optional) honks, then release.
Press & Release the Program Button
to proceed to the next step.
Setting 2 With 14pin Connector- Gas/Diesel Mode (Auxiliary Connector Pin 12)
1) (-) Input
1 Flash/Honk
(-) Glow Plug input. Waits maximum 30 seconds then starts.
2) Time Delay
2 Flashes/Honks
Waits for approximately 15 seconds then remote starts.
*3) Gas/ (+) Input
3 Flashes/Honks
Waits 2 seconds to start if no diesel input is detected.
Press & Release the Program Button 2 Times (Setting 2)
Confirmed with 2 LED flashes.
Press & Hold the Program Button
until the appropriate # of park lights/horn (optional) honks, then release.
Press & Release the Program Button
to proceed to the next step.
Note:
Setting 2 will vary depending on the board layout 11 or 14 pin connectors.
Setting 3 Rearm Output (Auxiliary Connector Pin 1)
1) Type 1
1 Flash/Honk
Pulse after start and with lock. (Provides Lock Pulse)
2) Type 2
2 Flashes/Honks
Pulse after start only. (Provides Lock Pulse)
*3) Factory Re-arm 3 Flashes/Honks
Pulse with lock and after starter shutdown.
Press & Release the Program Button
3 Times (Setting 3) Confirmed with 3 LED flashes.
Press & Hold the Program Button
until the appropriate # of park lights/horn (optional) honks, then release.
Press & Release the Program Button
to proceed to the next step.
Ignition 3x
On/Off
On/Off On
Press and
Release the
Program
Button
Press and
Release the
Start button
for Menu 3
Press and
Release the
Program Switch
1x =Setting 1
2x =Setting 2
3x =Setting 3....
Press and
Hold the
Program Switch
1x = Option 1
2x = Option 2
3x = Option 3....
Page 18
INSTALLATION MANUAL