Preventive Maintenance
Weekly
Visually inspect the suction cups and water
deflectors for any deterioration. Replace as
needed.
Check the spindle speeds at each spindle.
Check that the lamp cycle time is at 24
seconds. If it is not, adjust by using the
speed potentiometer labeled
LAMP
.
Clockwise
to decrease
Counterclockwise
to increase
Replace the Hepa Pre-Filter
Coat speed: 400 RPM (+ or - 25)
Coat spin-off speed: 2000 RPM (+ or - 50)
1600 RPM (AST-1)
Wash speed: 1800 RPM (+ or - 50)
16