Installation instructions
Check that the electrical rating shown on the showers matches the mains supply.
A competent installer must undertake all installations.
If in any doubt, advice and assistance should be sought from a qualified plumber and/or
electrician.
Installations and wiring must conform to current BS7671 (IEE regulations - UK) and
“Part P” of the Building Regulations.
WARNING! DO NOT INSTALL THIS SHOWER IN A ROOM WHERE IT MAY BE SUBJECT
TO FREEZING
We recommend that the installation be done in the following sequence.
a) Fixing the shower to the wall
b) Plumbing
c) Electrical connections
a) Fixing the shower to the wall
1. Position the riser rail at a convenient height for majority of
users as recommended in diagram 5 and mark its position.
2. Position the heater so the sides of the unit are vertical and
the top is level with, or up to 0.6 metres (2ft) maximum
below the top of the riser rail. Choose a flat piece of wall to
avoid the possibility of distorting the back plate thus
making the front cover a poor fit.
3. Adjust the positions to get the most convenient
arrangement taking the following into account.
a) The possible need to use the handset over the sink for
hair washing etc.
b) The heater must not be mounted in the direct spray from the showerhead.
c) The handset must not be able to come into contact
with any used water in the bath or basin. If it can,
even after the hose has been retained by the hose
retainer (see diagram 13), then a vacuum breaker
must be fitted. It should be noted that these devices
are liable to minor leakage so they must be
positioned so that any drips are not detrimental.
4. Fix the riser rail with screws provided.
The fixing holes at the base of the brackets will be
disclosed by removing the plastic fronts.
Assemble as shown in diagram 13.
5. Decide the position of the electrical cable inside the
unit. If top or bottom entry is chosen (according to
diagram 6), cut away the walls of the back-plate as
shown in diagram 8. There is also the option to fit the
cable from the rear in the channel provided.
6. Decide the cut away position of entry of the cold water
pipe into the unit.
Cut away the back-plate and front cover as shown in
diagram 7 or 8.
There is also the option to have rear entry (see later section on plumbing).
Diagram 6
Diagram 5
6