How your shower works 

 

Your shower is designed for convenience, economy and safety of use 

 

1.  Water is heated instantaneously as it flows over the heating elements in the copper heating 

tube. (Diagram 2). 
 

2.  The required water temperature is achieved by adjusting the 

rate of water flow. Diagram 3 shows the principle involved in 
relating temperature rise to flow rate. The higher the water flow 
the lower the temperature rise, and vice versa.                                  
The temperature of the water supplied from the mains can vary 
considerably throughout the year from 5 to 20

°

C. This means 

that in Winter, the flow rate will be less than in the Summer to 
achieve the same outlet temperature. In Summer the 
‘MEDIUM’ power setting may give adequate hot water. 

Diagram 2

 

Содержание AX310

Страница 1: ...Shower Handbook IMPORTANT Please retain this booklet for future reference We offer a technical advisory service on the telephone to contractors and other customers with problems in the field RING 084...

Страница 2: ...ng push button D only The electricity to the elements is then disconnected and the adjacent light will flash water will continue to flow for approximately 5 seconds before switching off This reduces t...

Страница 3: ...t have a serial number How your shower works Your shower is designed for convenience economy and safety of use 1 Water is heated instantaneously as it flows over the heating elements in the copper hea...

Страница 4: ...of pressure occur within the shower 9 There are a number of defined spray plate settings modes patterns adjustable by rotating the spray plate see diagram 4 The modes patterns have a positive click to...

Страница 5: ...wing water off Raise position of handset f Broken parts Please contact our spares department on 0844 372 7750 Fitting instructions are provided with spares PROFESSIONAL SERVICE If the previous checks...

Страница 6: ...ons to get the most convenient arrangement taking the following into account a The possible need to use the handset over the sink for hair washing etc b The heater must not be mounted in the direct sp...

Страница 7: ...connected to the mains cold water supply This must have a minimum running pressure of 100kPa 1 0 bar 4 5 p s i and a maximum pressure of 1000kPa 10 bar 145 p s i Before connecting the pipe work to the...

Страница 8: ...ulations If in doubt consult a qualified electrician 1 The shower is designed for a single phase A C electrical supply Please check the rating plate on the unit to see what details apply 2 The table i...

Страница 9: ...and then operate the shower as explained previously and check a That the water gets to a satisfactory temperature b Power selection does give a change in water temperature c Check again for leaks d Th...

Страница 10: ...DAMAGE REPLACE IF NECESSARY OR EVERY TWO YEARS WITH OUR APPROVED PART Additional Accessories Catalogue Number White 2 metre Shower hose 83 792578 WRAS Listed Water Isolating Valve 93 792452 Shower de...

Страница 11: ...11 Diagram 13...

Страница 12: ...or ULTRA FINISHING LIMITED WIDOW HILL ROAD HEASANDFORD INDUSTRIAL ESTATE BURNLEY LANCS BB10 2BE TEL 01282 436934 FAX 01282 428915 Technical Advice Line 0844 372 7766 Website www ultra group co uk A4 L...