3. Installation

3.1 Location

The Ultra-Aire should be located near the existing air handling system 
to minimize the required ductwork for connecting the Ultra-Aire to 
the existing air handling system.The controls for the Ultra-Aire are 
remote from the unit and must be located in the space that is to be 
conditioned. The controls are low voltage (24 volt) and should be 
connected to the Ultra-Aire with low voltage thermostat cable.

If fresh air ventilation is desired, thought should be given to the 
location for the fresh air ducting. A 6" round duct will have to be 
installed on the Ultra-Aire and run to the outside of the structure to 
bring in fresh air. Use an 8" insulated round duct for lengths of more 
than 25' or if more than 100 CFM is needed.

3.2 Electrical Requirements

The Ultra-Aire plugs into a common grounded outlet on a 15 Amp 
circuit. It draws between 6 and 7 Amps under normal operating 
conditions. If used in a wet area (pool, spa room, or basement prone 
to flooding), a ground fault interrupter protected circuit is required.

The installer must supply the wiring between the Ultra-Aire and the 
control panel. Be sure to safely route the control wires to prevent 
damage during installation. Be careful not to cross the wires when 
connecting the Ultra-Aire and the remote control panel or damage to 
the transformer may result.

The remote controls of the Ultra-Aire are powered by a low voltage 
circuit (24 Vac) and must NEVER contact or be connected to a high 
voltage circuit. The control wires leaving the Ultra-Aire and the 
remote control panels are color coded to prevent confusion. Some of 
the control wires leaving the Ultra-Aire may not be used with certain 
control panels and should be left safely disconnected with wire 
nuts taped onto the stripped ends. Be sure to consult the electrical 
schematic in this manual or on the front panel of the Ultra-Aire before 
making the control connections.

 

 WARNING! 

Do not allow the yellow lead 

from the Ultra-Aire to contact the red lead or orange 

lead from the Ultra-Aire or damage to the transformer 

will result.
NOTE: Reset the ventilation timer before attempting to 

program after initial installation. The timer may not  ..

operate correctly until it is reset.

3.3 Condensate Removal

Condensate drains by gravity via the clear hose extending from the 
unit. Route the hose to a floor drain. Use care to keep the hose as flat 
to the floor as possible; excessive humps will prevent proper drainage. 
We do not call for a trap since there is an internal trap with this unit. 
If the Ultra-Aire is located too far from a floor drain for the attached 
hose to reach, inexpensive 1⁄2" PVC pipe can be used to extend it. It is 
commonly available in 10' lengths from building supply, plumbing and 

hardware stores. It will slide tightly inside the end of the drain hose. 
If more than one length of pipe is required, they can be joined with a 
short piece cut from the end of the drain hose. 

An optional condensate pump may be installed if a lift is required to 
dispose of the condensate. The condensate pump kit can be ordered 
direct from the factory. See item 27 on page 21.

3.4 Ducting

3.4A Installing Duct Collars

The Ultra-Aire is equipped with 8" and 6" round inlet collars and an 
8" round white exhaust collar. The 8" and 6" round inlet collars are 
designed with tabs that fold under the top of the Ultra-Aire. The 8" 
round white exhaust collar is attached to the Ultra-Aire by (4) screws.

To install the inlet collars:

 Insert the tabs of the collar into the hole in 

the top of the Ultra-Aire and fold the tabs up to attach to the Ultra-Aire. 

To install the exhaust collar:

 Bend the (4) tabs toward the inside of 

the collar 90°. Attach the collar to the Ultra-Aire cabinet using 1⁄2" 
long #8 sheet metal screws. DO NOT use screws longer than 1⁄2" to 
attach this collar or damage to the refrigeration system may result.

3.4B Ducting for Dehumidification

For the ideal installation, draw air from the central part of the home 
and return it to the isolated areas of the home like the bedrooms, 
den, utility room, or family room. The ductwork of the existing heating 
system can be used to supply air to the home. If the existing supply 
goes to isolated areas of the home, discharge the supply of the 
Ultra-Aire into the supply of the existing heating system. If the existing 
heating system incorporates a central supply, installation of a separate 
supply duct from the Ultra-Aire to each isolated area is recommended. 
DO NOT draw air directly from the kitchen, laundry, or basement. All 
flexible ducting connected to the Ultra-Aire should be UL listed.

The inlet of the Ultra-Aire is the 8" diameter hole on top of the unit. An 
8" round collar is supplied with the unit to attach to round duct. The 
duct may be permanently attached to the collar. A 6" round collar is 
provided with the unit to attach to the 6" hole in the top. The 6" collar 
should be capped if fresh make-up air is not desired. If fresh make-up 
air is desired see section 3.4C.

The outlet of the Ultra-Aire is located on the side of the unit. A second 
8" round collar is supplied with the unit and can be attached using the 
screws provided and the pre-punched holes in the cabinet side. 

A length of 10 feet or more of acoustical flex ducting on the outlet of 
the Ultra-Aire will reduce air noise from the blower. A length of flexible 
ducting on all Ultra-Aire duct connections is recommended to reduce 
noise and vibration transmitted to rigid ductwork in the structure. 

Ducting the Ultra-Aire as mentioned in sections 3.4A-3.4G requires 
consideration of the following points:

SAFETY PRECAUTIONS

3

Ultra-Aire 100V Installer’s & Owner’s Manual

Содержание 100V

Страница 1: ...resh outdoor air may be ducted to the unit via a six inch round duct This provides fresh air to dilute pollutants and maintain high oxygen content in the air The amount of fresh air ventilation can be regulated by a variety of dampers and controls Air Filtration The UA 100V includes air filtration to improve indoor air quality A MERV 11 media filter is standard An optional MERV 14 deep pleated 95 ...

Страница 2: ...NEL INACCESSIBLE Avoid directing the discharge air at people or over the water in pool areas If used near a pool or spa be certain there is NO chance the unit could fall into the water splashed and that it is plugged into a GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET DO NOT use the device as a bench or table DO NOT place the device directly on structural members A drain pan MUST be placed under the...

Страница 3: ... building supply plumbing and hardware stores It will slide tightly inside the end of the drain hose If more than one length of pipe is required they can be joined with a short piece cut from the end of the drain hose An optional condensate pump may be installed if a lift is required to dispose of the condensate The condensate pump kit can be ordered direct from the factory See item 27 on page 21 ...

Страница 4: ... calling 1 800 533 7533 for recommendations regarding the use of higher flows with your specific application The outside air duct should be connected to the 6 round collar on top of the unit The 6 round collar includes a manual damper Adjust the manual damper to provide the desired amount of fresh air for ventilation The amount of fresh air should be based on the size and occupancy of the residenc...

Страница 5: ...By ducting this way the air inside the structure will circulate through the Ultra Aire to be filtered and dehumidified Connect a duct from outside to the 6 collar of the Ultra Aire if you wish to provide fresh make up air 3 5 Quiet Installation A length of 10 feet or more of acoustical flex ducting on the outlet of the Ultra Aire will reduce air noise from the blower A length of flexible ducting o...

Страница 6: ...dity Range Accuracy 10 95 RH 5 Auxillary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 2 Size 4 95 L x 1 06 W x 4 19 H Major Operations n Digital control of Relative Humidity Digital Set Point n Fan Filter Operation n Programmable Ventilation Timer n Large easy to read backlit LCD display n Easy interaction with air handler fan Interlock Lockout n High Temperature Cut Out n Dryout Cycle ...

Страница 7: ... efficiency pleated paper filter Do not attempt to clean the high efficiency pleated paper filter It should be replaced when it becomes restrictive See Figure 7 7 Service CAUTION Servicing the Ultra Aire with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death serious bodily injury and or property damage Only qualified service people...

Страница 8: ...n by reversing the above procedure 7 6 Compressor Capacitor Replacement This compressor is equipped with a two terminal external overload and a run capacitor but no start capacitor or relay See Figure 4 CAUTION ELECTRICAL SHOCK HAZARD Electrical power must be present to perform some tests These tests should be performed by a qualified service person 7 6A Checking Compressor Motor Circuits Perform ...

Страница 9: ... suction line filter driers will probably clean up the system If sludge is evident in the discharge line it will likely be found in the suction line This indicates the compressor burned out will running Sludge and acid have been pumped throughout the system Several changes of the liquid and suction filter driers will probably be necessary to cleanse the system 5 Correct the system fault that cause...

Страница 10: ...entilation timer is not activated to prevent over ventilating the structure when the unit is dehumidifying or recirculating the indoor air The electric ventilation timer operates on 24 Vac from the control circuit DO NOT connect high voltage to the damper motor or damage to the motor may result DO NOT force the blade of the damper by hand or damage to the damper motor may result The damper opens i...

Страница 11: ...ULTRA AIRE 100V PICTORIAL ELECTRICAL DIAGRAM N O WHT WHT 11 Ultra Aire 100V Installer s Owner s Manual ...

Страница 12: ...ly 9 4029168 1 Compressor 10 4029169 1 Compressor Overload 11 4028226 1 Condenser Coil 12 4022445 1 Cord Wire Harness 13 4029510 1 Filter Drier 14 4021626 1 Hose Drain Pan 56 ID x 8 15 4022484 1 Relay SPST 24 Vac 30A 16 4020924 1 Relay SPDT 24 Vac 15A 17 4033032 05 1 Run Capacitor 45 MFD 370V 18 4025741 1 Thermostat Defrost 4021648 1 Defrost Control Mounting Clip 19 4022487 1 Transformer 120 24 Va...

Страница 13: ... 90 95 4022220 1 Condensate Pump Kit 4023672 1 Damper Duct 6 Diameter Electrically Actuated not shown 4023647 1 Damper Check 8 Diameter not shown 4021475 1 MERV 11 Filter 16 x 20 x 2 4022489 1 MERV 14 Filter 16 x 20 x 4 4022220 1 Pump Kit 4023484 1 Attic Insulation Kit 4023672 1 6 Motorized Damper 4020656 1 6 Inlet Exhaust Hood 4023647 1 8 Gravity Damper 4020646 1 8 Butterfly Damper ...

Страница 14: ...costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilities As a further condition to obtaining warranty coverage hereunder the Customer must send a valid warranty claim to Therma Stor such that Therma Stor receives such claim prior to the end of the ap...

Страница 15: ...hermastor com Information in this document is subject to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved ...

Отзывы: