Ultimate Power

www.upinverters.com

- 9 -

3.5 Power Switch

There are three different working statuses

for SD inverter: “On”, “Off” and “Ready”.

When power switch is in “Off” position, the

inverter is powered off.

When power switch is turned to “ON”, the

inverter is powered on.

When power switch is turned to “Ready”,

the inverter will charge the battery when

there is qualified AC input. If there is no AC

power input, the inverter waits for 12Vdc remote start signal to go into inverter mode. Once the

12Vdc remote start is activated, the inverter powers on. When the 12Vdc remote start is de-activated,

the inverter goes to “Ready” mode again.

SD Series Idle Power Consumption

Model Type

On Mode

Ready Mode

Idle Power

Quiescent Current

UP12/2000SD-CG

30W

2.2A

15W

UP12/2500SD-CG

37.5W

3A

15W

UP12/3000SD-CG

45W

3.8A

15W

When in the search sense mode, the green power LED will blink and the inverter will make a ticking

sound. At full output voltage, the green power LED will light steadily and the inverter will make a

steady humming sound. When the inverter is used as an “uninterruptible” power supply the search

sense mode function should be defeated.

3.6 Protections

The SD Series inverter is equipped with extensive protections against various harsh situations/faults.

These protections include:

AC Input over voltage protection/AC Input low voltage protection

Low battery alarm/High battery alarm

Over temperature protection/Over load protection

Short Circuit protection (1s after fault)

Back feeding protection

When Over temperature /Over load occur, after the fault is cleared, the master switch has to be reset

to restart the inverter. The inverter will go to over temp protection when the heat sinks temp. ≥105ºC

(221

), and will go to Fault (shutdown Output) after 30 seconds. The switch has to be reset to

activate the inverter. The SD Series Inverter is with back feeding protection which avoids presenting

an AC voltage on the AC input terminal in Invert mode. After the reason for fault is cleared, the

inverter has to be reset to start working.

Содержание UP12/2000SD-CG

Страница 1: ...e Wave Inverter Charger User Manual Models UP12 2000SD CG UP12 2500SD CG UP12 3000SD CG 115 N East Street Coudersport PA 16915 Phone 888 447 5920 Fax 610 317 8514 E Mail info ultimatepower com Web www...

Страница 2: ......

Страница 3: ...cal Performances 5 3 1 Invert 5 3 2 AC Charger 6 3 3 AC Transfer 8 3 4 Auto Frequency Adjust 8 3 5 Power Switch 9 3 6 Protections 9 3 7 Remote Control 10 3 8 LED Indicator 11 3 9 Audible Alarm 11 3 10...

Страница 4: ...avoid a risk of fire and electronic shock Make sure that existing wiring is in good electrical condition and that wire size is not undersized Do not operate the Inverter with damaged or substandard wi...

Страница 5: ...a severe burn 1 2 5 To reduce the risk of injury charge only rechargeable batteries such as deep cycle lead acid lead antimony lead calcium gel cell absorbed mat and NiCad NiFe or Lithium battery Oth...

Страница 6: ...al Drawing Models UP12 2000SD CG UP12 2500SD CG UP12 3000SD CG Inverter physical description 1 DC input Openings Positive Negative Allows the DC input 2 RJ45 Remote Panel Port Connects to the remote c...

Страница 7: ...power with depleted batteries 2 3 10 30A through current ability 2 3 11 Multiple speed controlled cooling fan 2 3 12 Extensive protections against various harsh situations 3 Electrical Performances 3...

Страница 8: ...ed with an active PFC Power Factor Corrected multistage battery charger The PFC feature is used to control the amount of power used to charge the batteries in order to obtain a power factor as close a...

Страница 9: ...ith infrequent use of the batteries or if the batteries have been left discharged so low that they will not accept a charge This cycle is a very high voltage charge cycle designed to try to break down...

Страница 10: ...henever AC power falls below the VAC Trip voltage 90 VAC default setting the inverter automatically transfers back to the Invert Mode with minimum interruption to your appliances as long as the invert...

Страница 11: ...output voltage the green power LED will light steadily and the inverter will make a steady humming sound When the inverter is used as an uninterruptible power supply the search sense mode function sho...

Страница 12: ...s disconnected if the switch panel is in Ready position The 12Vdc remote start is with the same priority as ON Only when both panels and 12Vdc remote control are turned to Unit Off position will the i...

Страница 13: ...ep 0 5s every 5s Battery Voltage High Inverter green LED Lighting and the buzzer beep 0 5s every 1s and Fault after 60s Invert Mode Over Load 1 110 load 125 10 No audible alarm in 14 minutes Beeps 0 5...

Страница 14: ...the lead acid battery leads to high losses in capacity and early aging In different applications different low voltage disconnection level is preferred For example for solar application user intended...

Страница 15: ...harging mode the inverter will stay in standby mode without sensing loads It won t output any power even if a load is turned on or a qualified AC input is present The inverter will not perform any fun...

Страница 16: ...off after battery charging is finished The auto gen start feature will only work with generators which have automatic starting capability The generator must have start and stop controls i e an electr...

Страница 17: ...er contains capacitors that may produce a spark when first connected to battery Do not mount in a confined a battery or gas compartment 4 3 AC Wiring We recommend using 10 to 5Awg wire to connect to t...

Страница 18: ...verter Charger The following chart is designed to help you quickly pinpoint the most common inverter failures Indicator and Buzzer Indicator on top cover LED on Remote Switch Status Item SHORE POWER O...

Страница 19: ...frequency Charger is supplying a lower charge rate Charger controls are improperly set Low AC input voltage Loose battery or AC input connections Refer to the section on adjusting the Charger Rate So...

Страница 20: ...nufacture of said component provided such goods are installed maintained and used in accordance with Ultimate Power and the manufacture s written instructions 3 Ultimate Power s sole liability and the...

Страница 21: ...Starting Electric Motor 2HP 3HP 3HP Output Waveform Pure Sine wave Same as input Bypass mode Nominal Efficiency 85 Peak 83 Peak 83 Peak Line Mode Efficiency 95 Power Factor 0 9 1 0 Nominal Output Vol...

Страница 22: ...ow Voltage re engage 100V 4 High Voltage Trip 140V 4 High Voltage re engage 135V 4 Max Input AC Voltage 150VAC Nominal Input Frequency 60Hz Low Freq Trip 57 0 3Hz for 60Hz Low Freq re engage 58 0 3Hz...

Страница 23: ...Ultimate Power www upinverters com 21 Notes...

Страница 24: ...614 00506 00...

Отзывы: