LAS 260.1
– Date 07/2023
Operation
Page 27
S3 switch for ecoflow CS
®
:
-
S3
switch is in the position “
0
”
o
ecoflow CS
®
“OFF”
Control range of the potentiometer in position “0”
The suction power can be individually adjusted via the
potentiometer on the front of the unit. Clockwise rotation
allows you to continuously increase the suction power,
while counter-clockwise rotation continuously reduces the
suction power.
The rotational speed of the blower can freely adjusted up
to the maximum rotational speed.
-
S3
switch is in the position “
I
”
o
ecoflow CS
®
in medium-pressure operation
“ON”
Control range of the potentiometer in position “I”
Medium-pressure operation between 150 Pa - 1,000 Pa
Operating mode suitable up to a suction power of 230 m³/h
-
S3
switch is in the position “
II
”
o
ecoflow CS
®
in high-
pressure operation “ON”
Control range of the potentiometer in position “II”
High-pressure operation between 150 Pa - 5,000 Pa
Operating mode suitable up to a suction power of 130 m³/h
NOTICE
Before changing the ecoflow CS
®
mode, switch the device off
and wait at least 1 minute before switching it back on again.